Unexplained Syncope Evaluated by Electrophysiologic Studies and Head-up Tilt Testing

Sra, Jasbir S., Anderson, Alfred J., Sheikh, Shabbir H., Avitall, Boaz, Tchou, Patrick J., Troup, Paul J., Gilbert, Carol J., Akhtar, Masood, Jazayeri, Mohammad R.·1991·Annals of Internal Medicine

Abstract

OBJECTIVE: To determine the clinical characteristics of subgroups of patients with unexplained syncope having electrophysiologic studies and head-up tilt testing and to assess the efficacy of various therapies. DESIGN: Retrospective study. SETTING: Inpatient services of a tertiary referral center. PATIENTS: Eighty-six consecutively referred patients with unexplained syncope. MEASUREMENTS: All patients had electrophysiologic examinations. Patients with negative results subsequently had head-up tilt testing. MAIN RESULTS: Twenty-nine (34%) patients (group 1) had abnormal electrophysiologic results, with sustained monomorphic ventricular tachycardia induced in 72%. Thirty-four (40%) patients (group 2) had syncope provoked by head-up tilt testing. The cause of syncope remained unexplained in 23 (26%) patients (group 3). Structural heart disease was present in 76%, 6%, and 30% of groups 1, 2, and 3, respectively. In group 1, pharmacologic or nonpharmacologic therapy was recommended based on electrophysiologic evaluation. All group 2 patients had negative results on head-up tilt testing while receiving oral beta blockers (27 patients) or disopyramide (7 patients). Group 3 patients did not receive any specific therapy. During a median follow-up period of 18.5 months, syncope recurred in 9 (10%) patients. CONCLUSIONS: The combination of electrophysiologic evaluation and head-up tilt testing can identify the underlying cause of syncope in as many as 74% of patients presenting with unexplained syncope. Therapeutic strategies formulated according to the results of these diagnostic tests appear to prevent syncope effectively in most patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-114-12-1013

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 222

Metadata

Authors
Sra, J. S., Anderson, A. J., Sheikh, S. H., Avitall, B., Tchou, P. J., Troup, P. J., Gilbert, C. J., Akhtar, M., & Jazayeri, M. R.
Venue
Annals of Internal Medicine
Published
1991-06-15
Volume
114
Issue
12
Pages
1013-1019
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2020762911
Cited by
222
References
1
FWCI
18.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Unexplained Syncope Evaluated by Electrophysiologic Studies and Head-up Tilt Testing. https://app.cochat.ai/papers/10.7326/0003-4819-114-12-1013
The paper
Sra, J. S., Anderson, A. J., Sheikh, S. H., Avitall, B., Tchou, P. J., Troup, P. J., Gilbert, C. J., Akhtar, M., & Jazayeri, M. R. (1991). Unexplained Syncope Evaluated by Electrophysiologic Studies and Head-up Tilt Testing. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-114-12-1013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.