CoChat

Ambulatory Blood Pressure Monitoring and Blood Pressure Self-Measurement in the Diagnosis and Management of Hypertension

Appel, Lawrence J., Stason, William B. · 1993 · Annals of Internal Medicine
Cited by 206

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To review published evidence on the use of ambulatory and self-measurement devices in the diagnosis and management of hypertension. DATA SOURCES: Computerized literature searches and manual review of bibliographies. STUDY SELECTION: Articles documenting original research pertaining to the diagnosis, treatment, or prognosis of hypertension using ambulatory or self-measurement devices. RESULTS: Studies that have compared office, self-measured, and ambulatory blood pressures have documented substantial, but nonsystematic, differences. Such findings have raised concern over the appropriateness of diagnosing hypertension and initiating drug therapy in individuals with high office blood pressure but comparatively low self-measured or ambulatory blood pressure ("office" or "white coat" hypertension). Evidence from a large number of cross-sectional studies and a single prospective study suggests that blood pressure- related end-organ damage is more closely associated with ambulatory than with office blood pressure. Less evidence supports self-measured blood pressure in this regard, and data are insufficient to compare ambulatory and self-measured blood pressure in terms of cardiovascular disease risk prediction. The estimated resource cost of an ambulatory blood pressure test is approximately $120, whereas charges range from $100 to $450. The annualized resource cost of blood pressure self-measurement is $50 or less. On a national level, the annual direct costs of ambulatory blood pressure monitoring could be as high as $6 billion, if this technique were used routinely to diagnose and monitor hypertensive patients. The extent to which direct costs would be offset by savings from less frequent or more efficient treatment for hypertension cannot be estimated reliably. Several practical and technical issues also detract from the potential usefulness of ambulatory and self-measurement devices. Finally, there is some evidence that office blood pressures measured by well-trained nonphysicians may serve as an alternative to ambulatory and self-measurement techniques in estimating usual blood pressure. CONCLUSION: Limited clinical applications of ambulatory blood pressure monitoring and blood pressure self-measurement in the diagnosis and management of hypertension appear to be warranted. Endorsement of these technologies for routine clinical use, however, will require more convincing evidence of their clinical effectiveness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-118-11-199306010-00008

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 206

Metadata

Authors
Appel, L. J., & Stason, W. B.
Venue
Annals of Internal Medicine
Published
1993-06-01
Volume
118
Issue
11
Pages
867-882
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2062460487
Cited by
206
References
0
FWCI
6.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ambulatory Blood Pressure Monitoring and Blood Pressure Self-Measurement in the Diagnosis and Management of Hypertension. https://app.cochat.ai/papers/10.7326/0003-4819-118-11-199306010-00008
The paper
Appel, L. J., & Stason, W. B. (1993). Ambulatory Blood Pressure Monitoring and Blood Pressure Self-Measurement in the Diagnosis and Management of Hypertension. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-118-11-199306010-00008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.