The DOI matches its Crossref record.
Fine-Needle Aspiration Biopsy of the Thyroid: An Appraisal
Abstract
OBJECTIVE: To review the literature on the utility of fine-needle aspiration biopsy in the diagnostic management of nodular thyroid disease. DATA SOURCES: Relevant articles published in major English-language medical journals during the last 10 years. DATA EXTRACTION: Articles were reviewed to assess the results of fine-needle aspiration biopsy and its effect on thyroid management and cost of care. DATA SYNTHESIS: Fine-needle aspiration biopsy of the thyroid gland is safe, inexpensive, minimally invasive, and highly accurate in the diagnosis of nodular thyroid disease. Four cytologic diagnostic categories are used. Rates for these categories, based on data pooled from seven series, were as follows: benign, 69%; suspicious, 10%; malignant, 4%; and nondiagnostic, 17%. Analysis of recent data suggests a false-negative rate of 1% to 11%, a false-positive rate of 1% to 8%, a sensitivity of 65% to 98%, and a specificity of 72% to 100%. Limitations of fine-needle aspiration are related to the skill of the aspirator, the expertise of the cytologist, and the difficulty in distinguishing some benign cellular adenomas from their malignant counterparts. The introduction of fine-needle aspiration has had a substantial effect on the management of patients with thyroid nodules. The percentage of patients undergoing thyroidectomy has decreased by 25%, and the yield of carcinoma in patients who undergo surgery has increased from 15% to at least 30%. Fine-needle aspiration has decreased the cost of care by 25%. CONCLUSIONS: Fine-needle aspiration biopsy is safe, accurate, and cost-effective. The procedure has a central role in the management of thyroid nodules and should be used as the initial diagnostic test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Management of Simple Nodular Goiter: Current Status and Future Perspectives
Hegedüs, L., Bonnema, S. J., & Bennedbæk, F. N. (2003) · Endocrine Reviews · doi:10.1210/er.2002-0016 · Cited by 710
Leenhardt, L., Grosclaude, P., & Chérié-Challine, L. (2004) · Thyroid · doi:10.1089/thy.2004.14.1056 · Cited by 384
Fine needle aspiration cytology of thyroid nodules at Kenyatta National Hospital, Nairobi
Sang, C. K., Sekadde-Kigondu, C., & Muchiri, L. (2008) · East African Medical Journal · doi:10.4314/eamj.v84i3.9513 · Cited by 7
Metadata
- Authors
- Gharib, H., & Goellner, J. R.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1993-02-15
- Volume
- 118
- Issue
- 4
- Pages
- 282-289
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2035453768
- Cited by
- 1,193
- References
- 0
- FWCI
- 13.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fine-Needle Aspiration Biopsy of the Thyroid: An Appraisal. https://app.cochat.ai/papers/10.7326/0003-4819-118-4-199302150-00007
- The paper
- Gharib, H., & Goellner, J. R. (1993). Fine-Needle Aspiration Biopsy of the Thyroid: An Appraisal. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-118-4-199302150-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.