Fine-Needle Aspiration Biopsy of the Thyroid: An Appraisal
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To review the literature on the utility of fine-needle aspiration biopsy in the diagnostic management of nodular thyroid disease. DATA SOURCES: Relevant articles published in major English-language medical journals during the last 10 years. DATA EXTRACTION: Articles were reviewed to assess the results of fine-needle aspiration biopsy and its effect on thyroid management and cost of care. DATA SYNTHESIS: Fine-needle aspiration biopsy of the thyroid gland is safe, inexpensive, minimally invasive, and highly accurate in the diagnosis of nodular thyroid disease. Four cytologic diagnostic categories are used. Rates for these categories, based on data pooled from seven series, were as follows: benign, 69%; suspicious, 10%; malignant, 4%; and nondiagnostic, 17%. Analysis of recent data suggests a false-negative rate of 1% to 11%, a false-positive rate of 1% to 8%, a sensitivity of 65% to 98%, and a specificity of 72% to 100%. Limitations of fine-needle aspiration are related to the skill of the aspirator, the expertise of the cytologist, and the difficulty in distinguishing some benign cellular adenomas from their malignant counterparts. The introduction of fine-needle aspiration has had a substantial effect on the management of patients with thyroid nodules. The percentage of patients undergoing thyroidectomy has decreased by 25%, and the yield of carcinoma in patients who undergo surgery has increased from 15% to at least 30%. Fine-needle aspiration has decreased the cost of care by 25%. CONCLUSIONS: Fine-needle aspiration biopsy is safe, accurate, and cost-effective. The procedure has a central role in the management of thyroid nodules and should be used as the initial diagnostic test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Bethesda System for Reporting Thyroid Cytopathology
Cibas, E. S., & Ali, S. Z. (2009) · American Journal of Clinical Pathology · doi:10.1309/ajcpphlwmi3jv4la · Cited by 2,040
Hegedüs, L. (2004) · New England Journal of Medicine · doi:10.1056/nejmcp031436 · Cited by 1,502
The Bethesda System for Reporting Thyroid Cytopathology
Cibas, E. S., & Ali, S. Z. (2009) · Thyroid · doi:10.1089/thy.2009.0274 · Cited by 1,261
Frates, M. C., Benson, C. B., Charboneau, J. W., Cibas, E. S., Clark, O. H., Coleman, B. G., Cronan, J. J., Doubilet, P. M., Evans, D. B., Goellner, J. R., et al. (2005) · Radiology · doi:10.1148/radiol.2373050220 · Cited by 1,227
Self-citationGharib, H., Papini, E., Paschke, R., Duick, D. S., Valcavi, R., Hegedüs, L., Vitti, P., Gharib, H., Papini, E., Paschke, R., et al. (2010) · Endocrine Practice · doi:10.4158/10024.gl · Cited by 1,088
Self-citationSherma, S. I. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12488-9 · Cited by 925
Long-term assessment of a multidisciplinary approach to thyroid nodule diagnostic evaluation
Yassa, L., Cibas, E. S., Benson, C. B., Frates, M. C., Doubilet, P. M., Gawande, A. A., Moore, F. D., Kim, B. W., Nosé, V., Marqusee, E., et al. (2007) · Cancer · doi:10.1002/cncr.23116 · Cited by 718
Management of Simple Nodular Goiter: Current Status and Future Perspectives
Hegedüs, L., Bonnema, S. J., & Bennedbæk, F. N. (2003) · Endocrine Reviews · doi:10.1210/er.2002-0016 · Cited by 710
Frates, M. C., Benson, C. B., Doubilet, P. M., Kunreuther, E., Contreras, M., Cibas, E. S., Orcutt, J., Moore, F. D., Larsen, P. R., Marqusee, E., et al. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-0690 · Cited by 694
Gharib, H., Papini, E., Valcavi, R., Baskin, H. J., Crescenzi, A., Dottorini, M. E., Duick, D. S., Guglielmi, R., Hamilton, C. R., Zeiger, M. A., et al. (2006) · Endocrine Practice · doi:10.4158/ep.12.1.63 · Cited by 681
Self-citationBoelaert, K., Horacek, J., Holder, R. L., Watkinson, J. C., Sheppard, M. C., & Franklyn, J. A. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-0527 · Cited by 534
DANESE, D., SCIACCHITANO, S., FARSETTI, A., ANDREOLI, M., & PONTECORVI, A. (1998) · Thyroid · doi:10.1089/thy.1998.8.15 · Cited by 522
Sebag, F., Vaillant-Lombard, J., Berbis, J., Griset, V., Henry, J. F., Petit, P., & Oliver, C. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-0766 · Cited by 424
Nikiforov, Y. E., Carty, S. E., Chiosea, S. I., Coyne, C., Duvvuri, U., Ferris, R. L., Gooding, W. E., LeBeau, S. O., Ohori, N. P., Seethala, R. R., et al. (2015) · Thyroid · doi:10.1089/thy.2015.0305 · Cited by 394
Thyroid Nodules: Clinical Importance, Assessment, and Treatment
Gharib, H., & Papini, E. (2007) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2007.04.009 · Cited by 394
Self-citationLeenhardt, L., Grosclaude, P., & Chérié-Challine, L. (2004) · Thyroid · doi:10.1089/thy.2004.14.1056 · Cited by 384
Baloch, Z. W., Cibas, E. S., Clark, D. P., Layfield, L. J., Ljung, B.-M., Pitman, M. B., & Abati, A. (2008) · CytoJournal · doi:10.1186/1742-6413-5-6 · Cited by 382
Assessment of Nondiagnostic Ultrasound-Guided Fine Needle Aspirations of Thyroid Nodules
Alexander, E. K., Heering, J. P., Benson, C. B., Frates, M. C., Doubilet, P. M., Cibas, E. S., & Marqusee, E. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-020865 · Cited by 358
Fine-Needle Aspiration Cytology of the Thyroid: A 12-Year Experience With 11,000 Biopsies
Gharib, H., Goellner, J. R., & Johnson, D. A. (1993) · Clinics in Laboratory Medicine · doi:10.1016/s0272-2712(18)30434-7 · Cited by 346
Self-citationRago, T., Vitti, P., Chiovato, L., Mazzeo, S., De Liperi, A., Miccoli, P., Viacava, P., Bogazzi, F., Martino, E., & Pinchera, A. (1998) · European Journal of Endocrinology · doi:10.1530/eje.0.1380041 · Cited by 343
Griffith, O. L., Melck, A., Jones, S. J. M., & Wiseman, S. M. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2006.06.7330 · Cited by 314
Leenhardt, L. (1999) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.84.1.24 · Cited by 312
Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Masses
CARMECI, C., JEFFREY, R. B., McDOUGALL, I. R., NOWELS, K. W., & WEIGEL, R. J. (1998) · Thyroid · doi:10.1089/thy.1998.8.283 · Cited by 307
Thyroid Nodule Size and Prediction of Cancer
Kamran, S. C., Marqusee, E., Kim, M. I., Frates, M. C., Ritner, J., Peters, H., Benson, C. B., Doubilet, P. M., Cibas, E. S., Barletta, J., et al. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-2968 · Cited by 292
Suen, K. (1996) · Diagnostic Cytopathology · doi:10.1002/(sici)1097-0339(199607)15:1<84::aid-dc18>3.0.co;2-8 · Cited by 264
PET and [18F]-FDG in oncology: A clinical update
Conti, P. S., Lilien, D. L., Hawley, K., Keppler, J., Grafton, S. T., & Bading, J. R. (1996) · Nuclear Medicine and Biology · doi:10.1016/0969-8051(96)00074-1 · Cited by 259
Salvatore, G., Giannini, R., Faviana, P., Caleo, A., Migliaccio, I., Fagin, J. A., Nikiforov, Y. E., Troncone, G., Palombini, L., Basolo, F., et al. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-032221 · Cited by 259
Continuing Controversies in the Management of Thyroid Nodules
Castro, M. R., & Gharib, H. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-142-11-200506070-00011 · Cited by 256
Self-citationMcCoy, K. L., Jabbour, N., Ogilvie, J. B., Ohori, N. P., Carty, S. E., & Yim, J. H. (2007) · Surgery · doi:10.1016/j.surg.2007.08.012 · Cited by 242
Popoveniuc, G., & Jonklaas, J. (2012) · Medical Clinics of North America · doi:10.1016/j.mcna.2012.02.002 · Cited by 233
CHANGING CONCEPTS IN THE DIAGNOSIS AND MANAGEMENT OF THYROID NODULES
Gharib, H. (1997) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(05)70282-6 · Cited by 221
Self-citationEvaluation and Management of the Solid Thyroid Nodule
Burch, H. B. (1995) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(18)30019-7 · Cited by 212
FINE-NEEDLE ASPIRATION BIOPSY OF THE THYROID
Belfiore, A., & La Rosa, G. L. (2001) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(05)70191-2 · Cited by 211
Inohara, H., Honjo, Y., Yoshii, T., Akahani, S., Yoshida, J.-I., Hattori, K., Okamoto, S., Sawada, T., Raz, A., & Kubo, T. (1999) · Cancer · doi:10.1002/(sici)1097-0142(19990601)85:11<2475::aid-cncr25>3.0.co;2-1 · Cited by 187
“Although we believe FNAB is the most useful diagnostic modality for thyroid nodules, false-negative results are not unusual for papillary carcinoma, which is the most common thyroid malignancy.(6,7) The accuracy of FNAB in the preoperative diagnosis of nodular thyroid diseases primarily depends on the skill and experi…”
BackgroundFine needle aspiration cytology of thyroid nodules at Kenyatta National Hospital, Nairobi
Sang, C. K., Sekadde-Kigondu, C., & Muchiri, L. (2008) · East African Medical Journal · doi:10.4314/eamj.v84i3.9513 · Cited by 7
Metadata
- Authors
- Gharib, H., & Goellner, J. R.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1993-02-15
- Volume
- 118
- Issue
- 4
- Pages
- 282-289
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2035453768
- Cited by
- 1,193
- References
- 0
- FWCI
- 13.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.