CoChat

The Utility of Duplex Ultrasound Scanning of the Renal Arteries for Diagnosing Significant Renal Artery Stenosis

Olin, Jeffrey W., Piedmonte, Marion R., Young, Jess R., DeAnna, Susan, Grubb, Michael, Childs, Mary Beth · 1995 · Annals of Internal Medicine
Cited by 383

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To determine the utility of duplex ultrasound scanning of the renal arteries in identifying patients with renal artery stenosis of 60% or more and in excluding patients with either normal renal arteries or renal artery stenosis of less than 60%. DESIGN: A prospective, blinded study. SETTING: Large tertiary referral center. PATIENTS: 102 consecutive patients (44 men and 58 women with a mean age [+@- SD] of 63.3 +/- 13.4 years) who had both duplex ultrasound scanning of the renal arteries and renal arteriography. All patients who were studied had hypertension that was difficult to control, unexplained azotemia, or associated peripheral vascular disease (alone or in combination), giving them a high pretest likelihood of renovascular disease. MAIN OUTCOME MEASUREMENTS: Peak systolic and end diastolic velocities, renal-aortic ratios, resistive index, and kidney sizes. RESULTS: Sixty-two of 63 arteries with stenosis of less than 60% using arteriography were correctly identified by duplex ultrasound scanning. Thirty-one of 32 arteries with 60% to 79% stenosis using arteriography were correctly identified as having 60% to 99% stenosis on duplex ultrasound, whereas 67 of 69 arteries with 80% to 99% stenosis on arteriography were correctly identified as having 60% to 99% stenosis on ultrasound. Twenty-two of 23 arteries with total occlusion on arteriography were correctly identified by duplex ultrasound. The overall sensitivity of duplex ultrasound compared with arteriography was 0.98, the specificity was 0.98, the positive predictive value was 0.99, and the negative predictive value was 0.97. CONCLUSION: Duplex ultrasound scanning of the renal arteries is an ideal screening test because it is noninvasive and can predict the presence or absence of renal artery stenosis with a high degree of accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-122-11-199506010-00004

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 383

Metadata

Authors
Olin, J. W., Piedmonte, M. R., Young, J. R., DeAnna, S., Grubb, M., & Childs, M. B.
Venue
Annals of Internal Medicine
Published
1995-06-01
Volume
122
Issue
11
Pages
833-838
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W1972178282
Cited by
383
References
0
FWCI
15.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Utility of Duplex Ultrasound Scanning of the Renal Arteries for Diagnosing Significant Renal Artery Stenosis. https://app.cochat.ai/papers/10.7326/0003-4819-122-11-199506010-00004
The paper
Olin, J. W., Piedmonte, M. R., Young, J. R., DeAnna, S., Grubb, M., & Childs, M. B. (1995). The Utility of Duplex Ultrasound Scanning of the Renal Arteries for Diagnosing Significant Renal Artery Stenosis. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-122-11-199506010-00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.