The Utility of Duplex Ultrasound Scanning of the Renal Arteries for Diagnosing Significant Renal Artery Stenosis
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To determine the utility of duplex ultrasound scanning of the renal arteries in identifying patients with renal artery stenosis of 60% or more and in excluding patients with either normal renal arteries or renal artery stenosis of less than 60%. DESIGN: A prospective, blinded study. SETTING: Large tertiary referral center. PATIENTS: 102 consecutive patients (44 men and 58 women with a mean age [+@- SD] of 63.3 +/- 13.4 years) who had both duplex ultrasound scanning of the renal arteries and renal arteriography. All patients who were studied had hypertension that was difficult to control, unexplained azotemia, or associated peripheral vascular disease (alone or in combination), giving them a high pretest likelihood of renovascular disease. MAIN OUTCOME MEASUREMENTS: Peak systolic and end diastolic velocities, renal-aortic ratios, resistive index, and kidney sizes. RESULTS: Sixty-two of 63 arteries with stenosis of less than 60% using arteriography were correctly identified by duplex ultrasound scanning. Thirty-one of 32 arteries with 60% to 79% stenosis using arteriography were correctly identified as having 60% to 99% stenosis on duplex ultrasound, whereas 67 of 69 arteries with 80% to 99% stenosis on arteriography were correctly identified as having 60% to 99% stenosis on ultrasound. Twenty-two of 23 arteries with total occlusion on arteriography were correctly identified by duplex ultrasound. The overall sensitivity of duplex ultrasound compared with arteriography was 0.98, the specificity was 0.98, the positive predictive value was 0.99, and the negative predictive value was 0.97. CONCLUSION: Duplex ultrasound scanning of the renal arteries is an ideal screening test because it is noninvasive and can predict the presence or absence of renal artery stenosis with a high degree of accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.174526 · Cited by 3,708
Self-citationThe Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
on behalf of The Japanese Society of Hypertension Committee for Guidelines for the Management of Hypertension, Ogihara, T., Kikuchi, K., Matsuoka, H., Fujita, T., Higaki, J., Horiuchi, M., Imai, Y., Imaizumi, T., Ito, S., et al. (2014) · Hypertension Research · doi:10.1038/hr.2014.68 · Cited by 1,385
Slovut, D. P., & Olin, J. W. (2004) · New England Journal of Medicine · doi:10.1056/nejmra032393 · Cited by 744
Self-citationSlovut, D. P., & Olin, J. W. (2005) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-005-0017-z · Cited by 591
Self-citationBlum, U., Krumme, B., Flügel, P., Gabelmann, A., Lehnert, T., Buitrago-Tellez, C., Schollmeyer, P., & Langer, M. (1997) · New England Journal of Medicine · doi:10.1056/nejm199702133360702 · Cited by 508
Olin, J. W., Gornik, H. L., Bacharach, J. M., Biller, J., Fine, L. J., Gray, B. H., Gray, W. A., Gupta, R., Hamburg, N. M., Katzen, B. T., et al. (2014) · Circulation · doi:10.1161/01.cir.0000442577.96802.8c · Cited by 475
Self-citationAtherosclerotic Vascular Disease Conference: Writing Group III: Pathophysiology
Faxon, D. P., Fuster, V., Libby, P., Beckman, J. A., Hiatt, W. R., Thompson, R. W., Topper, J. N., Annex, B. H., Rundback, J. H., Fabunmi, R. P., et al. (2004) · Circulation · doi:10.1161/01.cir.0000128520.37674.ef · Cited by 414
Prospective Study of Atherosclerotic Disease Progression in the Renal Artery
Caps, M. T., Perissinotto, C., Zierler, R. E., Polissar, N. L., Bergelin, R. O., Tullis, M. J., Cantwell-Gab, K., Davidson, R. C., & Strandness, D. E. (1998) · Circulation · doi:10.1161/01.cir.98.25.2866 · Cited by 407
Vasbinder, G. B. C., Nelemans, P. J., Kessels, A. G. H., Kroon, A. A., de Leeuw, P. W., & van Engelshoven, J. M. A. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-6-200109180-00009 · Cited by 387
Risk of atrophy in kidneys with atherosclerotic renal artery stenosis
Caps, M. T., Zierler, R. E., Polissar, N. L., Bergelin, R. O., Beach, K. W., Cantwell-Gab, K., Casadei, A., Davidson, R. C., & Strandness, D. E. (1998) · Kidney International · doi:10.1046/j.1523-1755.1998.00805.x · Cited by 330
Leung, A. A., Daskalopoulou, S. S., Dasgupta, K., McBrien, K., Butalia, S., Zarnke, K. B., Nerenberg, K., Harris, K. C., Nakhla, M., Cloutier, L., et al. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.03.005 · Cited by 318
Diagnosis, management, and future developments of fibromuscular dysplasia
Olin, J. W., & Sealove, B. A. (2011) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2010.10.066 · Cited by 275
Self-citationGuidelines for the Reporting of Renal Artery Revascularization in Clinical Trials
Rundback, J. H., Sacks, D., Kent, K. C., Cooper, C., Jones, D., Murphy, T., Rosenfield, K., White, C., Bettmann, M., Cortell, S., et al. (2002) · Circulation · doi:10.1161/01.cir.0000029805.87199.45 · Cited by 249
“Because the criteria for duplex ultrasound (US) evaluation of the renal arteries uses a vessel categorization of 60% diameter stenosis (85,86), this threshold may be used rather than 50% diameter stenosis if confirmed by angiography.”
MethodA Prospective Study of Disease Progression in Patients With Atherosclerotic Renal Artery Stenosis*
ZIERLER, R., BERGELIN, R., DAVIDSON, R., CANTWELLCAB, K., POLISSAR, N., & STRANDNESSJR, D. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00196-3 · Cited by 217
Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2004)
Japanese Society of Hypertension (2006) · Hypertension Research · doi:10.1291/hypres.29.s1 · Cited by 216
Magnetic Resonance Angiography for the Diagnosis of Renal Artery Stenosis: A Meta-analysis
Tan, K. T., van Beek, E. J. R., Brown, P. W. G., van Delden, O. M., Tijssen, J., & Ramsay, L. E. (2002) · Clinical Radiology · doi:10.1053/crad.2002.0941 · Cited by 202
Renovascular Hypertension and Ischemic Nephropathy
Textor, S. C., & Lerman, L. (2010) · American Journal of Hypertension · doi:10.1038/ajh.2010.174 · Cited by 196
Gray, B. H., Olin, J. W., Childs, M. B., Sullivan, T. M., & Bacharach, J. M. (2002) · Vascular Medicine · doi:10.1191/1358863x02vm456oa · Cited by 189
Self-citationWilliams, G. J., Macaskill, P., Chan, S. F., Karplus, T. E., Yung, W., Hodson, E. M., & Craig, J. C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0355 · Cited by 185
“[89] 1995 102 – X X 54.”
Ischemic renal diseases: New insights into old entities
Meyrier, A., Hill, G. S., & Simon, P. (1998) · Kidney International · doi:10.1046/j.1523-1755.1998.00968.x · Cited by 182
“Prospective studies based on duplex Doppler scanning in patients with diffuse atherosclerosis yielded 15% with renal artery involvement [48, 49].”
BackgroundDiagnosis of renovascular disease by intra- and extrarenal Doppler scanning
Krumme, B., Blum, U., Schwertfeger, E., Flügel, P., Höllstin, F., Schollmeyer, P., & Rump, L. C. (1996) · Kidney International · doi:10.1038/ki.1996.440 · Cited by 175
“Recently, Olin et al [25] found a sensitivity of 98% by analyzing peak and end diastolic flow velocity of the main renal arteries.”
BackgroundMethodResultInfluentialDworkin, L. D., & Cooper, C. J. (2009) · New England Journal of Medicine · doi:10.1056/nejmcp0809200 · Cited by 164
Metadata
- Authors
- Olin, J. W., Piedmonte, M. R., Young, J. R., DeAnna, S., Grubb, M., & Childs, M. B.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1995-06-01
- Volume
- 122
- Issue
- 11
- Pages
- 833-838
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1972178282
- Cited by
- 383
- References
- 0
- FWCI
- 15.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.