The DOI matches its Crossref record.
Noninvasive Carotid Artery Testing: A Meta-analytic Review
Abstract
PURPOSE: To compare the operating characteristics of six noninvasive tests for carotid artery stenosis. DATA SOURCES: A structured search was done using MEDLINE, reference lists from selected articles, and bibliographies from neurology textbooks that focused on the diagnosis of carotid artery stenosis in humans. The search yielded 568 articles. STUDY SELECTION: Articles were selected if the noninvasive test results they presented used carotid angiography as the reference standard for comparison, if carotid artery occlusion was considered as a separate category, and if contingency tables could be constructed. DATA EXTRACTION: At least two physicians reviewed all selected articles. Items abstracted included patient demographics, study design, sites of patient enrollment, whether the interpretation of test outcomes was blinded, and specific results. Sensitivity, specificity, receiver operating characteristic (ROC) curves, and summary measures of effectiveness for each test were calculated. RESULTS: Carotid duplex ultrasonography, carotid Doppler ultrasonography, and magnetic resonance angiography have sensitivities between 0.82 and 0.86, specificities at 0.98, and test-effectiveness measures at or exceeding 3.0 when predicting 100% occlusion. For carotid stenosis of 70% or more, these three tests and supraorbital Doppler ultrasonography all have sensitivities of 0.83 to 0.86, specificities of 0.89 to 0.94, test-effectiveness measures approaching 3.0, and composite ROC areas of 0.91 to 0.92. Limiting analysis to studies that enrolled consecutive patients and those in which interpretation of the noninvasive tests was independent of the angiograms did not substantially change our results. CONCLUSIONS: Carotid duplex ultrasonography, carotid Doppler ultrasonography, and magnetic resonance angiography are all similarly successful at predicting 100% carotid artery occlusion and 70% stenosis. Other factors, such as cost, availability, and local experience may influence the decision to use these tests to screen for carotid artery atherosclerosis that may respond to surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jauch, E. C., Saver, J. L., Adams, H. P., Bruno, A., Connors, J. J. (., Demaerschalk, B. M., Khatri, P., McMullan, P. W., Qureshi, A. I., Rosenfield, K., et al. (2013) · Stroke · doi:10.1161/str.0b013e318284056a · Cited by 7,634
Beyond Accuracy, F-Score and ROC: A Family of Discriminant Measures for Performance Evaluation
Sokolova, M., Japkowicz, N., & Szpakowicz, S. (2006) · Lecture Notes in Computer Science · doi:10.1007/11941439_114 · Cited by 1,974
Alberts, M. J., Latchaw, R. E., Selman, W. R., Shephard, T., Hadley, M. N., Brass, L. M., Koroshetz, W., Marler, J. R., Booss, J., Zorowitz, R. D., et al. (2005) · Stroke · doi:10.1161/01.str.0000170622.07210.b4 · Cited by 585
Latchaw, R. E., Alberts, M. J., Lev, M. H., Connors, J. J., Harbaugh, R. E., Higashida, R. T., Hobson, R., Kidwell, C. S., Koroshetz, W. J., Mathews, V., et al. (2009) · Stroke · doi:10.1161/strokeaha.108.192616 · Cited by 452
Brott, T. G., Halperin, J. L., Abbara, S., Bacharach, J. M., Barr, J. D., Bush, R. L., Cates, C. U., Creager, M. A., Fowler, S. B., Friday, G., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.11.006 · Cited by 447
Metadata
- Authors
- Blakeley, D. D., Oddone, E. Z., Hasselblad, V., Simel, D. L., & Matchar, D. B.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1995-03-01
- Volume
- 122
- Issue
- 5
- Pages
- 360-367
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2033647101
- Cited by
- 215
- References
- 0
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Carotid Artery Testing: A Meta-analytic Review. https://app.cochat.ai/papers/10.7326/0003-4819-122-5-199503010-00007
- The paper
- Blakeley, D. D., Oddone, E. Z., Hasselblad, V., Simel, D. L., & Matchar, D. B. (1995). Noninvasive Carotid Artery Testing: A Meta-analytic Review. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-122-5-199503010-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.