Cost-Effectiveness of Implantable Cardioverter Defibrillators Relative to Amiodarone for Prevention of Sudden Cardiac Death
The DOI matches its Crossref record.
Abstract
BACKGROUND: Implantable cardioverter defibrillators (ICDs) are remarkably effective in terminating ventricular arrhythmias, but they are expensive and the extent to which they extend life is unknown. The marginal cost-effectiveness of ICDs relative to amiodarone has not been clearly established. OBJECTIVE: To compare the cost-effectiveness of a third-generation implantable ICD with that of empirical amiodarone treatment for preventing sudden cardiac death in patients at high or intermediate risk. DESIGN: A Markov model was used to evaluate health and economic outcomes of patients who received an ICD, amiodarone, or a sequential regimen that reserved ICD for patients who had an arrhythmia during amiodarone treatment. MEASUREMENTS: Life-years gained, quality-adjusted life-years gained, costs, and marginal cost-effectiveness. RESULTS: For the base-case analysis, it was assumed that treatment with an ICD would reduce the total mortality rate by 20% to 40% at 1 year compared with amiodarone and that the ICD generator would be replaced every 4 years. In high-risk patients, if an ICD reduces total mortality by 20%, patients who receive an ICD live for 4.18 quality-adjusted life-years and have a lifetime expenditure of $88,400. Patients receiving amiodarone live for 3.68 quality-adjusted life-years and have a lifetime expenditure of $51,000. Marginal cost-effectiveness of an ICD relative to amiodarone is $74,400 per quality-adjusted life-year saved. If an ICD reduces mortality by 40%, the cost-effectiveness of ICD use is $37,300 per quality-adjusted life-year saved. Both choice of therapy (an ICD or amiodarone) and the cost-effectiveness ratio are sensitive to assumptions about quality of life. CONCLUSIONS: Use of an ICD will cost more than $50,000 per quality-adjusted life-year gained unless it reduces all-cause mortality by 30% or more relative to amiodarone. Current evidence does not definitively support or exclude a benefit of this magnitude, but ongoing randomized trials have sufficient statistical power to do so.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Self-citationWriting Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Self-citationEpstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Self-citationTracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 732
Strickberger, S. A., Hummel, J. D., Bartlett, T. G., Frumin, H. I., Schuger, C. D., Beau, S. L., Bitar, C., & Morady, F. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00297-3 · Cited by 586
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 552
Self-citationCost-Effectiveness of Implantable Cardioverter–Defibrillators
Sanders, G. D., Hlatky, M. A., & Owens, D. K. (2005) · New England Journal of Medicine · doi:10.1056/nejmsa051989 · Cited by 547
Self-citationImplantable Cardioverter–Defibrillators
DiMarco, J. P. (2003) · New England Journal of Medicine · doi:10.1056/nejmra035432 · Cited by 290
The Cost-effectiveness of Automatic Implantable Cardiac Defibrillators: Results From MADIT
Mushlin, A. I., Hall, W. J., Zwanziger, J., Gajary, E., Andrews, M., Marron, R., Zou, K. H., & Moss, A. J. (1998) · Circulation · doi:10.1161/01.cir.97.21.2129 · Cited by 276
Ezekowitz, J. A., Armstrong, P. W., & McAlister, F. A. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-6-200303180-00007 · Cited by 265
Cost Effectiveness of Lung-Volume–Reduction Surgery for Patients with Severe Emphysema
(2003) · New England Journal of Medicine · doi:10.1056/nejmsa030448 · Cited by 234
Cost-effectiveness of drotrecogin alfa (activated) in the treatment of severe sepsis*
Angus, D. C., Linde-Zwirble, W. T., Clermont, G., Ball, D. E., Basson, B. R., Ely, E. W., Laterre, P.-F., Vincent, J.-L., Bernard, G., & van Hout, B. (2003) · Critical Care Medicine · doi:10.1097/00003246-200301000-00001 · Cited by 224
Nanthakumar, K., Epstein, A. E., Kay, G. N., Plumb, V. J., & Lee, D. S. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.08.054 · Cited by 217
Sheldon, R., Connolly, S., Krahn, A., Roberts, R., Gent, M., & Gardner, M. (2000) · Circulation · doi:10.1161/01.cir.101.14.1660 · Cited by 215
“They were eligible for enrollment if, in the absence of acute ischemia or reversible factors, they had (1) documented VF, (2) out-of-hospital resuscitated cardiac arrest, (3) documented VT causing syncope, (4) documented sustained VT at a rate of$150 bpm causing presyncope or angina in a patient with LVEF #35%, or (5)…”
BackgroundTeerlink, J. R., Jalaluddin, M., Anderson, S., Kukin, M. L., Eichhorn, E. J., Francis, G., Packer, M., & Massie, B. M. (2000) · Circulation · doi:10.1161/01.cir.101.1.40 · Cited by 210
Primary Prevention of Sudden Cardiac Death in Heart Failure: Will the Solution Be Shocking?
Uretsky, B. F., & Sheahan, R. G. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00361-6 · Cited by 198
“(78), using a sophisticated Markovian model comparing the incremental cost of ICD with amiodarone in SCD survivors, concluded a somewhat similar cost for ICD per life-year saved (average cost approximately $74,000).”
MethodMedical technology as a key driver of rising health expenditure: disentangling the relationship
Sorenson, C., Drummond, & Bhuiyan-Khan (2013) · ClinicoEconomics and Outcomes Research · doi:10.2147/ceor.s39634 · Cited by 195
Gasparini, M., Menozzi, C., Proclemer, A., Landolina, M., Iacopino, S., Carboni, A., Lombardo, E., Regoli, F., Biffi, M., Burrone, V., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp247 · Cited by 162
Optimizing Value From Cardiac Rehabilitation
Leggett, L. E., Hauer, T., Martin, B.-J., Manns, B., Aggarwal, S., Arena, R., Austford, L. D., Meldrum, D., Ghali, W., Knudtson, M. L., et al. (2015) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2015.05.015 · Cited by 34
Metadata
- Authors
- Owens, D. K., Sanders, G. D., Harris, R. A., McDonald, K. M., Heidenreich, P. A., Dembitzer, A. D., & Hlatky, M. A.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1997-01-01
- Volume
- 126
- Issue
- 1
- Pages
- 1-12
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2079981753
- Cited by
- 186
- References
- 0
- FWCI
- 10.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.