The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Cost-Effectiveness of Implantable Cardioverter–Defibrillators
Open accessAbstract
BACKGROUND: Eight randomized trials have evaluated whether the prophylactic use of an implantable cardioverter-defibrillator (ICD) improves survival among patients who are at risk for sudden death due to left ventricular systolic dysfunction but who have not had a life-threatening ventricular arrhythmia. We assessed the cost-effectiveness of the ICD in the populations represented in these primary-prevention trials. METHODS: We developed a Markov model of the cost, quality of life, survival, and incremental cost-effectiveness of the prophylactic implantation of an ICD, as compared with control therapy, among patients with survival and mortality rates similar to those in each of the clinical trials. We modeled the efficacy of the ICD as a reduction in the relative risk of death on the basis of the hazard ratios reported in the individual clinical trials. RESULTS: Use of the ICD increased lifetime costs in every trial. Two trials--the Coronary Artery Bypass Graft (CABG) Patch Trial and the Defibrillator in Acute Myocardial Infarction Trial (DINAMIT)--found that the prophylactic implantation of an ICD did not reduce the risk of death and thus was both more expensive and less effective than control therapy. For the other six trials--the Multicenter Automatic Defibrillator Implantation Trial (MADIT) I, MADIT II, the Multicenter Unsustained Tachycardia Trial (MUSTT), the Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) trial, the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) trial, and the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT)--the use of an ICD was projected to add between 1.01 and 2.99 quality-adjusted life-years (QALY) and between 68,300 dollars and 101,500 dollars in cost. Using base-case assumptions, we found that the cost-effectiveness of the ICD as compared with control therapy in these six populations ranged from 34,000 dollars to 70,200 dollars per QALY gained. Sensitivity analyses showed that this cost-effectiveness ratio would remain below 100,000 dollars per QALY as long as the ICD reduced mortality for seven or more years. CONCLUSIONS: Prophylactic implantation of an ICD has a cost-effectiveness ratio below 100,000 dollars per QALY gained in populations in which a significant device-related reduction in mortality has been demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cost-Effectiveness in Health and Medicine
(1996) · doi:10.1093/oso/9780195108248.001.0001 · Cited by 7,193
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489
Research works printed but not linked: 32
- Connolly SJ, 2000, Circulation, 101, 1297, 10.1161/01.CIR.101.11.1297 · DOI · Paper page
- 10.1056/NEJM199711273372202 · DOI · Paper page
- 10.1016/0002-8703(94)90101-5 · DOI · Paper page
- 10.1056/NEJMoa041489 · DOI · Paper page
- 10.1056/NEJMoa033088 · DOI · Paper page
- 10.1056/NEJMoa013474 · DOI · Paper page
- 10.1056/NEJM199711273372201 · DOI · Paper page
- 10.1056/NEJMp048354 · DOI
- 10.1177/0272989X9301300409 · DOI · Paper page
- 10.1177/0272989X8300300403 · DOI · Paper page
- Sanders GD, 2001, Ann Intern Med, 135, 870, 10.7326/0003-4819-135-10-200111200-00007 · DOI
- Owens DK, 1997, Ann Intern Med, 126, 1, 10.7326/0003-4819-126-1-199701010-00001 · DOI · Paper page
- 2004, Technol Eval Cent Asses Program Exec Summ, 19, 1
- 10.1016/j.ahj.2005.02.005 · DOI
- 10.1016/j.jacc.2005.02.077 · DOI
- Zipes DP, 1995, Circulation, 92, 59, 10.1161/01.CIR.92.1.59 · DOI
- 10.1016/S0735-1097(10)80260-8 · doi:10.1016/s0735-1097(10)80260-8
- 10.1016/S0735-1097(87)80477-1 · DOI
- 10.1016/0735-1097(92)90341-J · DOI
- 10.1177/0272989X9301300210 · DOI · Paper page
- 10.1177/0272989X9301300202 · DOI · Paper page
- Kuntz KM, 1996, Circulation, 94, 957, 10.1161/01.CIR.94.5.957 · DOI
- Lipscomb J, Weinstein MC, Torrance GW. Time preference. In: Gold MR, Siegel JE, Russell LB, Weinstein MC, eds. Cost effectiveness in health and medicine. New York: Oxford University Press, 1996:214-46.
- 10.1016/0002-9149(91)90263-K · DOI
- 10.1016/0735-1097(95)80013-7 · doi:10.1016/0735-1097(95)80013-7
- Every NR, 1997, Circulation, 96, 1770, 10.1161/01.CIR.96.6.1770 · doi:10.1161/01.cir.96.6.1770
- Irvine J, 2002, Am Heart J, 144, 282, 10.1067/mhj.2002.124049 · DOI · Paper page
- 10.1067/mhj.2002.125497 · DOI
- 10.1016/S1053-2498(01)00298-4 · DOI · Paper page
- 10.1001/jama.265.9.1145 · DOI
- 10.1377/hlthaff.24.1.42 · DOI
- 10.1016/j.ahj.2004.12.001 · doi:10.1016/j.ahj.2004.12.001
Cited by
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.592 · Cited by 5,866
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
Metadata
- Authors
- Sanders, G. D., Hlatky, M. A., & Owens, D. K.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2005-10-06
- Volume
- 353
- Issue
- 14
- Pages
- 1471-1480
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2000325901
- Cited by
- 547
- References
- 5
- FWCI
- 30.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cost-Effectiveness of Implantable Cardioverter–Defibrillators. https://app.cochat.ai/papers/10.1056/nejmsa051989
- The paper
- Sanders, G. D., Hlatky, M. A., & Owens, D. K. (2005). Cost-Effectiveness of Implantable Cardioverter–Defibrillators. New England Journal of Medicine. https://doi.org/10.1056/nejmsa051989
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.