Reliability of Tuberculin Skin Test Measurement
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Important management decisions depend on results of the tuberculin skin test. However, the test is subject to several potential errors, and its reliability has not been adequately studied. OBJECTIVE: To ascertain the reliability of tuberculin skin testing. DESIGN: Cross-sectional study. SETTING: University hospital. PARTICIPANTS: 96 persons who received a tuberculin skin test. MEASUREMENTS: Ballpoint-pen and palpation measures of induration. RESULTS: Global intra- and interobserver reliability coefficients of the ballpoint-pen technique were high. Five percent of the time, however, a second measurement by the same observer could be at least 2.7 mm less to 3.0 mm more than the first measurement and the measurement from the second observer could be at least 3.4 mm less to 3.7 mm more than the measurement from the first observer. This could lead to the reclassification of a positive test result as negative or vice versa. The area of imprecision was 38% less broad for the ballpoint-pen technique than for the palpation technique. CONCLUSION: Reading of tuberculin skin tests may frequently result in misclassifications when measurements are close to the cutoff point that separates negative from positive results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Menzies, D., Pai, M., & Comstock, G. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-5-200703060-00006 · Cited by 984
A systematic review of rapid diagnostic tests for the detection of tuberculosis infection
Dinnes, J., Deeks, J., Kunst, H., Gibson, A., Cummins, E., Waugh, N., Drobniewski, F., & Lalvani, A. (2007) · Health Technology Assessment · doi:10.3310/hta11030 · Cited by 666
SANAI, F. M., & BZEIZI, K. I. (2005) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2005.02645.x · Cited by 442
Lederman, M. M., Connick, E., Landay, A., Kuritzkes, D. R., Spritzler, J., St. Clair, M., Kotzin, B. L., Fox, L., Heath Chiozzi, M., Leonard, J. M., et al. (1998) · Journal of Infectious Diseases · doi:10.1086/515591 · Cited by 425
Cattamanchi, A., Smith, R., Steingart, K. R., Metcalfe, J. Z., Date, A., Coleman, C., Marston, B. J., Huang, L., Hopewell, P. C., & Pai, M. (2011) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0b013e31820b07ab · Cited by 297
Metadata
- Authors
- Pouchot, J., Grasland, A., Collet, C., Coste, J., Esdaile, J. M., & Vinceneux, P.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1997-02-01
- Volume
- 126
- Issue
- 3
- Pages
- 210-214
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1986611228
- Cited by
- 118
- References
- 2
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of Tuberculin Skin Test Measurement. https://app.cochat.ai/papers/10.7326/0003-4819-126-3-199702010-00005
- The paper
- Pouchot, J., Grasland, A., Collet, C., Coste, J., Esdaile, J. M., & Vinceneux, P. (1997). Reliability of Tuberculin Skin Test Measurement. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-126-3-199702010-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.