CoChat

A Comparison Study of Multiple Measures of Adherence to HIV Protease Inhibitors

Liu, Honghu, Golin, Carol E., Miller, Loren G., Hays, Ron D., Beck, C. Keith, Sanandaji, Sam, Christian, Judith, Maldonado, Tomasa, Duran, Dena, Kaplan, Andrew H., Wenger, Neil S. · 2001 · Annals of Internal Medicine
Cited by 758

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Poor adherence to HIV protease inhibitors may compromise the effectiveness of treatment. Few studies have compared methods for measuring adherence or have related adherence measures to a clinical outcome. OBJECTIVE: To examine the relationship among a composite score of adherence, the three primary measures of adherence, and HIV virologic response. DESIGN: Longitudinal cohort study. SETTING: Public HIV clinic. PATIENTS: 108 HIV-infected adults receiving protease inhibitors or non-nucleoside reverse transcriptase inhibitors who were monitored for 666 monthly intervals. MEASUREMENTS: Medication Event Monitoring System (MEMS), pill count, and interview combined into a composite adherence score (CAS), and HIV viral load. RESULTS: Mean antiretroviral adherence differed by adherence measure (MEMS, 0.63; pill count, 0.83; interview, 0.93; and CAS, 0.76). Composite adherence score decreased significantly over time. Composite adherence score, MEMS values, pill values, and interview values were statistically significantly associated with achievement of an undetectable viral load within 6 months of initiating therapy. Composite adherence score showed the strongest predictive relationship (odds ratios for a 10% increase in adherence for CAS, MEMS, pill count, and interview, respectively, were 1.26 [95% CI, 1.16 to 1.37], 1.13 [CI, 1.06 to 1.21], 1.10 [CI, 1.02 to 1.19], and 1.35 [CI, 0.94 to 1.94]). CONCLUSIONS: Different measures applied to the same patient suggest different levels of adherence. Adherence may be underestimated by MEMS and overestimated by pill count and interview. A summary measure combining several measures is more strongly related to a clinical response, but more practical measurement methods are needed for clinical use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-134-10-200105150-00011

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 758

Metadata

Authors
Liu, H., Golin, C. E., Miller, L. G., Hays, R. D., Beck, C. K., Sanandaji, S., Christian, J., Maldonado, T., Duran, D., Kaplan, A. H., & Wenger, N. S.
Venue
Annals of Internal Medicine
Published
2001-05-15
Volume
134
Issue
10
Pages
968-977
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2109763529
Cited by
758
References
26
FWCI
30.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison Study of Multiple Measures of Adherence to HIV Protease Inhibitors. https://app.cochat.ai/papers/10.7326/0003-4819-134-10-200105150-00011
The paper
Liu, H., Golin, C. E., Miller, L. G., Hays, R. D., Beck, C. K., Sanandaji, S., Christian, J., Maldonado, T., Duran, D., Kaplan, A. H., & Wenger, N. S. (2001). A Comparison Study of Multiple Measures of Adherence to HIV Protease Inhibitors. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-134-10-200105150-00011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.