CoChat
Cited by 195

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Is Duplex Ultrasonography Useful for the Diagnosis of Giant-Cell Arteritis?

Open access
Salvarani, Carlo, Silingardi, Mauro, Ghirarduzzi, Angelo, Lo Scocco, Giovanni, Macchioni, PierLuigi, Bajocchi, GianLuigi, Vinceti, Marco, Cantini, Fabrizio, Iori, Ido, Boiardi, Luigi · 2002 · Annals of Internal Medicine

Abstract

BACKGROUND: Evidence of a dark halo on ultrasonography has been considered a specific sign of giant-cell arteritis and may replace temporal artery biopsy for the diagnosis of giant-cell arteritis in patients with typical clinical manifestations. OBJECTIVE: To assess the usefulness of temporal artery duplex ultrasonography and to compare this mode of ultrasonography with physical examination of temporal arteries for the diagnosis of giant-cell arteritis in patients with suspected giant-cell arteritis or polymyalgia rheumatica. DESIGN: Diagnostic test study. SETTING: Several divisions of Reggio Emilia Hospital, Reggio Emilia, Italy. PATIENTS: 86 consecutive patients with a suspected diagnosis of giant-cell arteritis or polymyalgia rheumatica identified over a 22-month period. MEASUREMENTS: The temporal arteries were examined in all 86 patients. Duplex ultrasonography of the temporal arteries was then performed by two ultrasonographers who were unaware of the clinical diagnosis. Before corticosteroid therapy was started, temporal artery biopsies were performed in all patients at the site targeted by the ultrasonographer. RESULTS: A hypoechoic halo around the lumen of the temporal arteries had a sensitivity of only 40% (95% CI, 16% to 68%) and a specificity of 79% (CI, 68% to 88%) for the diagnosis of biopsy-proven giant-cell arteritis. The negative likelihood ratio was 0.8 (CI, 0.5 to 1.2), and the positive likelihood ratio was 1.9 (CI, 0.9 to 4.1). When the thickness of the halo was at least 1 mm, specificity increased to 93% (CI, 84% to 98%) and the positive likelihood ratio increased to 5.7 (CI, 2.0 to 16.2); however, sensitivity remained low at 40% (CI, 16% to 68%). On physical examination, temporal artery abnormalities had a higher sensitivity of 67% (CI, 38% to 88%), a higher specificity of 99% (CI, 92% to 100%), and a higher positive likelihood ratio of 47.3 (CI, 6.5 to 342.4) than did ultrasonographic findings. None of the patients with giant-cell arteritis had a normal temporal artery inspection and a hypoechoic halo on ultrasonography. CONCLUSION: Evidence on ultrasonography of a halo around temporal arteries, either any halo or a halo 1 mm or greater in thickness, only modestly increased the probability of biopsy-proven giant-cell arteritis but did not improve the diagnostic accuracy of a careful physical examination.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-137-4-200208200-00006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 195

Metadata

Authors
Salvarani, C., Silingardi, M., Ghirarduzzi, A., Lo Scocco, G., Macchioni, P., Bajocchi, G., Vinceti, M., Cantini, F., Iori, I., & Boiardi, L.
Venue
Annals of Internal Medicine
Published
2002-08-20
Volume
137
Issue
4
Pages
232-238
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2018834680
Cited by
195
References
1
FWCI
9.65
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Is Duplex Ultrasonography Useful for the Diagnosis of Giant-Cell Arteritis? https://app.cochat.ai/papers/10.7326/0003-4819-137-4-200208200-00006
The paper
Salvarani, C., Silingardi, M., Ghirarduzzi, A., Lo Scocco, G., Macchioni, P., Bajocchi, G., Vinceti, M., Cantini, F., Iori, I., & Boiardi, L. (2002). Is Duplex Ultrasonography Useful for the Diagnosis of Giant-Cell Arteritis? Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-137-4-200208200-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.