CoChat

A Quantitative Immunochemical Fecal Occult Blood Test for Colorectal Neoplasia

Levi, Zohar, Rozen, Paul, Hazazi, Rachel, Vilkin, Alex, Waked, Amal, Maoz, Eran, Birkenfeld, Shlomo, Leshno, Moshe, Niv, Yaron · 2007 · Annals of Internal Medicine
Cited by 326

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Guaiac-based fecal occult blood tests (FOBTs) for colorectal cancer screening are not specific for human hemoglobin and have low sensitivity. Automated-development, immunochemical FOBT is quality-controlled, is specific for human hemoglobin, and does not require diet restriction. OBJECTIVES: To measure the sensitivity and specificity of quantitative immunochemical fecal hemoglobin measurements for detection of cancer and advanced adenoma in patients undergoing colonoscopy, to determine fecal hemoglobin thresholds that give the highest posttest probability for neoplasia, and to determine the number of immunochemical FOBTs needed. DESIGN: Prospective, cross-sectional study. SETTING: Ambulatory endoscopy services of the main health medical organization in Tel Aviv, Israel. PARTICIPANTS: 1000 consecutive ambulatory patients--some asymptomatic but at increased risk for colorectal neoplasia and some symptomatic--who were undergoing elective colonoscopy and volunteered to prepare immunochemical FOBTs. INTERVENTION: The hemoglobin content of 3 bowel movements was measured, and the highest value was compared with colonoscopy findings. MEASUREMENTS: Sensitivity, specificity, predictive values, likelihood ratios, and 95% CIs of fecal hemoglobin measurements for clinically significant neoplasia, their relationship to the amount of fecal hemoglobin measured, and the number of immunochemical FOBTs performed. RESULTS: Colonoscopy identified clinically significant neoplasia in 91 patients (cancer in 17 patients and advanced adenomas in 74 patients). Using 3 immunochemical FOBTs and a hemoglobin threshold of 75 ng/mL of buffer, sensitivity and specificity were 94.1% (95% CI, 82.9% to 100.0%) and 87.5% (CI, 85.4% to 89.6%), respectively, for cancer and 67% (CI, 57.4% to 76.7%) and 91.4% (CI, 89.6% to 93.2%), respectively, for any clinically significant neoplasia. LIMITATIONS: The fecal sampling method is standardized, but the sample size depends on fecal consistency. Some patients were tested while discontinuing aspirin and anticoagulant therapies. Study patients were at increased risk, and results might not apply to average-risk populations. CONCLUSIONS: Quantitative immunochemical FOBT has good sensitivity and specificity for detection of clinically significant neoplasia. Test performance in screening average-risk populations is not known.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-146-4-200702200-00003

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 326

Metadata

Authors
Levi, Z., Rozen, P., Hazazi, R., Vilkin, A., Waked, A., Maoz, E., Birkenfeld, S., Leshno, M., & Niv, Y.
Venue
Annals of Internal Medicine
Published
2007-02-20
Volume
146
Issue
4
Pages
244-255
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W1986732380
Cited by
326
References
20
FWCI
16.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Quantitative Immunochemical Fecal Occult Blood Test for Colorectal Neoplasia. https://app.cochat.ai/papers/10.7326/0003-4819-146-4-200702200-00003
The paper
Levi, Z., Rozen, P., Hazazi, R., Vilkin, A., Waked, A., Maoz, E., Birkenfeld, S., Leshno, M., & Niv, Y. (2007). A Quantitative Immunochemical Fecal Occult Blood Test for Colorectal Neoplasia. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-146-4-200702200-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.