Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 707

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

Accuracy of Fecal Immunochemical Tests for Colorectal Cancer: Systematic Review and Meta-analysis

Open access
Lee, Jeffrey K., Liles, Elizabeth G., Bent, Stephen, Levin, Theodore R., Corley, Douglas A.·2014·Annals of Internal Medicine

Abstract

BACKGROUND: Performance characteristics of fecal immunochemical tests (FITs) to screen for colorectal cancer (CRC) have been inconsistent. PURPOSE: To synthesize data about the diagnostic accuracy of FITs for CRC and identify factors affecting its performance characteristics. DATA SOURCES: Online databases, including MEDLINE and EMBASE, and bibliographies of included studies from 1996 to 2013. STUDY SELECTION: All studies evaluating the diagnostic accuracy of FITs for CRC in asymptomatic, average-risk adults. DATA EXTRACTION: Two reviewers independently extracted data and critiqued study quality. DATA SYNTHESIS: Nineteen eligible studies were included and meta-analyzed. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of FITs for CRC were 0.79 (95% CI, 0.69 to 0.86), 0.94 (CI, 0.92 to 0.95), 13.10 (CI, 10.49 to 16.35), 0.23 (CI, 0.15 to 0.33), respectively, with an overall diagnostic accuracy of 95% (CI, 93% to 97%). There was substantial heterogeneity between studies in both the pooled sensitivity and specificity estimates. Stratifying by cutoff value for a positive test result or removal of discontinued FIT brands resulted in homogeneous sensitivity estimates. Sensitivity for CRC improved with lower assay cutoff values for a positive test result (for example, 0.89 [CI, 0.80 to 0.95] at a cutoff value less than 20 µg/g vs. 0.70 [CI, 0.55 to 0.81] at cutoff values of 20 to 50 µg/g) but with a corresponding decrease in specificity. A single-sample FIT had similar sensitivity and specificity as several samples, independent of FIT brand. LIMITATIONS: Only English-language articles were included. Lack of data prevented complete subgroup analyses by FIT brand. CONCLUSION: Fecal immunochemical tests are moderately sensitive, are highly specific, and have high overall diagnostic accuracy for detecting CRC. Diagnostic performance of FITs depends on the cutoff value for a positive test result. PRIMARY FUNDING SOURCE: National Institute of Diabetes and Digestive and Kidney Diseases and National Cancer Institute.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/m13-1484

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 56 references

Cited by

See all 707

Metadata

Authors
Lee, J. K., Liles, E. G., Bent, S., Levin, T. R., & Corley, D. A.
Venue
Annals of Internal Medicine
Published
2014-02-04
Volume
160
Issue
3
Pages
171-181
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W1990118688
Cited by
707
References
56
FWCI
27.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Fecal Immunochemical Tests for Colorectal Cancer: Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.7326/m13-1484
The paper
Lee, J. K., Liles, E. G., Bent, S., Levin, T. R., & Corley, D. A. (2014). Accuracy of Fecal Immunochemical Tests for Colorectal Cancer: Systematic Review and Meta-analysis. Annals of Internal Medicine. https://doi.org/10.7326/m13-1484

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.