An Externally Validated Model for Predicting Long-Term Survival after Exercise Treadmill Testing in Patients with Suspected Coronary Artery Disease and a Normal Electrocardiogram
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The exercise treadmill test is recommended for risk stratification among patients with intermediate to high pretest probability of coronary artery disease. Posttest risk stratification is based on the Duke treadmill score, which includes only functional capacity and measures of ischemia. OBJECTIVE: To develop and externally validate a post-treadmill test, multivariable mortality prediction rule for adults with suspected coronary artery disease and normal electrocardiograms. DESIGN: Prospective cohort study conducted from September 1990 to May 2004. SETTING: Exercise treadmill laboratories in a major medical center (derivation set) and a separate HMO (validation set). PATIENTS: 33,268 patients in the derivation set and 5821 in the validation set. All patients had normal electrocardiograms and were referred for evaluation of suspected coronary artery disease. MEASUREMENTS: The derivation set patients were followed for a median of 6.2 years. A nomogram-illustrated model was derived on the basis of variables easily obtained in the stress laboratory, including age; sex; history of smoking, hypertension, diabetes, or typical angina; and exercise findings of functional capacity, ST-segment changes, symptoms, heart rate recovery, and frequent ventricular ectopy in recovery. RESULTS: The derivation data set included 1619 deaths. Although both the Duke treadmill score and our nomogram-illustrated model were significantly associated with death (P < 0.001), the nomogram was better at discrimination (concordance index for right-censored data, 0.83 vs. 0.73) and calibration. We reclassified many patients with intermediate- to high-risk Duke treadmill scores as low risk on the basis of the nomogram. The model also predicted 3-year mortality rates well in the validation set: Based on an optimal cut-point for a negative predictive value of 0.97, derivation and validation rates were, respectively, 1.7% and 2.5% below the cut-point and 25% and 29% above the cut-point. LIMITATIONS: Blood test-based measures or left ventricular ejection fraction were not included. The nomogram can be applied only to patients with a normal electrocardiogram. Clinical utility remains to be tested. CONCLUSION: A simple nomogram based on easily obtained pretest and exercise test variables predicted all-cause mortality in adults with suspected coronary artery disease and normal electrocardiograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating the Yield of Medical Tests
Harrell, F. E. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03320430047030 · Cited by 3,490
Heart-rate Recovery Immediately After Exercise as a Predictor of Mortality
Cole, C. R., Blackstone, E. H., Pashkow, F. J., Snader, C. E., & Lauer, M. S. (1999) · New England Journal of Medicine · doi:10.1056/nejm199910283411804 · Cited by 1,935
Self-citationPrognostic value of treadmill exercise testing in elderly persons.
Goraya, T. Y., Jacobsen, S. J., Pellikka, P. A., Miller, T. D., Khan, A., Weston, S. A., Gersh, B. J., & Roger, V. L. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-132-11-200006060-00003 · Cited by 234
Lauer (2005) · doi:10.1161/circulationaha.105.166543 · Cited by 220
Aktas, M. K. (2004) · JAMA · doi:10.1001/jama.292.12.1462 · Cited by 193
Cited by
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Self-citationFletcher, G. F., Ades, P. A., Kligfield, P., Arena, R., Balady, G. J., Bittner, V. A., Coke, L. A., Fleg, J. L., Forman, D. E., Gerber, T. C., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829b5b44 · Cited by 2,235
Writing Committee Members, Greenland, P., Alpert, J. S., Beller, G. A., Benjamin, E. J., Budoff, M. J., Fayad, Z. A., Foster, E., Hlatky, M. A., Hodgson, J. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3182051b4c · Cited by 1,873
Self-citationGulati, M., Levy, P. D., Mukherjee, D., Amsterdam, E., Bhatt, D. L., Birtcher, K. K., Blankstein, R., Boyd, J., Bullock-Palmer, R. P., Conejo, T., et al. (2021) · Circulation · doi:10.1161/cir.0000000000001029 · Cited by 1,611
Virani, S. S., Newby, L. K., Arnold, S. V., Bittner, V., Brewer, L. C., Demeter, S. H., Dixon, D. L., Fearon, W. F., Hess, B., Johnson, H. M., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001168 · Cited by 1,598
Metadata
- Authors
- Lauer, M. S., Pothier, C. E., Magid, D. J., Smith, S. S., & Kattan, M. W.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2007-12-18
- Volume
- 147
- Issue
- 12
- Pages
- 821-828
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1983014140
- Cited by
- 90
- References
- 5
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Externally Validated Model for Predicting Long-Term Survival after Exercise Treadmill Testing in Patients with Suspected Coronary Artery Disease and a Normal Electrocardiogram. https://app.cochat.ai/papers/10.7326/0003-4819-147-12-200712180-00001
- The paper
- Lauer, M. S., Pothier, C. E., Magid, D. J., Smith, S. S., & Kattan, M. W. (2007). An Externally Validated Model for Predicting Long-Term Survival after Exercise Treadmill Testing in Patients with Suspected Coronary Artery Disease and a Normal Electrocardiogram. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-147-12-200712180-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.