Systematic Review: Comparative Effectiveness of Core-Needle and Open Surgical Biopsy to Diagnose Breast Lesions
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Most women undergoing breast biopsy are found not to have cancer. PURPOSE: To compare the accuracy and harms of different breast biopsy methods in average-risk women suspected of having breast cancer. DATA SOURCES: Databases, including MEDLINE and EMBASE, searched from 1990 to September 2009. STUDY SELECTION: Studies that compared core-needle biopsy diagnoses with open surgical diagnoses or clinical follow-up. DATA EXTRACTION: Data were abstracted by 1 of 3 researchers and verified by the primary investigator. DATA SYNTHESIS: 33 studies of stereotactic automated gun biopsy; 22 studies of stereotactic-guided, vacuum-assisted biopsy; 16 studies of ultrasonography-guided, automated gun biopsy; 7 studies of ultrasonography-guided, vacuum-assisted biopsy; and 5 studies of freehand automated gun biopsy met the inclusion criteria. Low-strength evidence showed that core-needle biopsies conducted under stereotactic guidance with vacuum assistance distinguished between malignant and benign lesions with an accuracy similar to that of open surgical biopsy. Ultrasonography-guided biopsies were also very accurate. The risk for severe complications is lower with core-needle biopsy than with open surgical procedures (<1% vs. 2% to 10%). Moderate-strength evidence showed that women in whom breast cancer was initially diagnosed by core-needle biopsy were more likely than women with cancer initially diagnosed by open surgical biopsy to be treated with a single surgical procedure (random-effects odds ratio, 13.7 [95% CI, 5.5 to 34.6]). LIMITATION: The strength of evidence was rated low for accuracy outcomes because the studies did not report important details required to assess the risk for bias. CONCLUSION: Stereotactic- and ultrasonography-guided core-needle biopsy procedures seem to be almost as accurate as open surgical biopsy, with lower complication rates. PRIMARY FUNDING SOURCE: Agency for Healthcare Research and Quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139 · cited 1×
“We performed meta-regressions with Meta-DiSc and assessed heterogeneity with the I(2) measure (12, 13).”
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552 · cited 2×
“In cases where a bivariate binomial regression model could not be fit (primarily owing to heterogeneity of study results), we meta-analyzed the data by using a random-effects model (11) and Meta-DiSc software (Unit of Clinical Biostatistics, Ramón y Cajal Hospital, Madrid, Spain).”
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763 · cited 1×
“We performed meta-regressions with Meta-DiSc and assessed heterogeneity with the I(2) measure (12, 13).”
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910 · cited 2×
“We did not assess the possibility of publication bias because statistical methods developed to assess the possibility of publication bias in treatment studies have been shown to be invalid for use with studies of diagnostic accuracy (14, 15).”
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 1×
“Case–control studies were excluded because they have been shown to overestimate the accuracy of diagnostic tests (4).”
A unification of models for meta-analysis of diagnostic accuracy studies
Harbord, R. M., Deeks, J. J., Egger, M., Whiting, P., & Sterne, J. A. C. (2007) · Biostatistics · doi:10.1093/biostatistics/kxl004 · Cited by 751 · cited 1×
“We meta-analyzed the data reported by the studies by using a bivariate mixed-effects binomial regression model described by Harbord and colleagues (9).”
Owens, D. K., Lohr, K. N., Atkins, D., Treadwell, J. R., Reston, J. T., Bass, E. B., Chang, S., & Helfand, M. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.03.009 · Cited by 513
Self-citationLarge-Core Needle Biopsy of Nonpalpable Breast Lesions
Meyer, J. E. (1999) · JAMA · doi:10.1001/jama.281.17.1638 · Cited by 248
Verkooijen, H. M. (2002) · International Journal of Cancer · doi:10.1002/ijc.10419 · Cited by 176
Ciatto, S., Houssami, N., Ambrogetti, D., Bianchi, S., Bonardi, R., Brancato, B., Catarzi, S., & Risso, G. G. (2006) · Breast Cancer Research and Treatment · doi:10.1007/s10549-006-9289-6 · Cited by 140
MIDAS: Stata module for meta-analytical integration of diagnostic test accuracy studies
Dwamena, B. A. (2007) · RePEc: Research Papers in Economics · Cited by 101
A system for rating the stability and strength of medical evidence
Treadwell, J. R., Tregear, S. J., Reston, J. T., & Turkelson, C. M. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-52 · Cited by 93
Self-citationLacquement, M. A., Mitchell, D. S. J., & Hollingsworth, A. B. (1999) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(99)00080-0 · Cited by 90 · cited 1×
“Most women who are referred for breast biopsy do not have malignant lesions and do not require follow-up treatment (2).”
Changing to core biopsy in an NHS breast screening unit
Britton, P. D., Flower, C. D. R., Freeman, A. H., Sinnatamby, R., Warren, R., Goddard, M. J., Wight, D. G. D., & Bobrow, L. G. (1997) · Clinical Radiology · doi:10.1016/s0009-9260(97)80156-0 · Cited by 77
Chiaie, L. D., & TERINDE, R. (2004) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1001 · Cited by 30
Rakha, E. A., El‐Sayed, M. E., Reed, J., Lee, A. H. S., Evans, A. J., & Ellis, I. O. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.12.002 · Cited by 27
Bruening, W., Schoelles, K. M., Treadwell, J., Launders, J. H., Fontanarosa, J., & Tipton, K. N. (2009) · Cited by 19
Self-citationOwens, D. K., Lohr, K. N., Atkins, D. C., Treadwell, J. R., Reston, J. T., Bass, E. B., Chang, S., & Helfand, M. (2009) · Cited by 17
Self-citationSutton, S., Dahlstrom, J. E., & Jain, S. (1997) · Australasian Radiology · doi:10.1111/j.1440-1673.1997.tb00607.x · Cited by 7
Ultrasound-guided biopsy of palpable breast masses
Khattar, S., Torp‐Pedersen, S., Horn, T. D., Krogh-Pedersen, I., Court‐Payen, M., & Lorentzen, T. (1997) · European Journal of Ultrasound · doi:10.1016/s0929-8266(97)00030-x · Cited by 6
Core biopsy of breast lesions.
Smyth, A. T., & Cederbom, G. J. (1994) · PubMed · Cited by 5
Cited by
Ductal Carcinoma In Situ of the Breast: A Systematic Review of Incidence, Treatment, and Outcomes
Virnig, B. A., Tuttle, T. M., Shamliyan, T., & Kane, R. L. (2010) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djp482 · Cited by 608
Feist, P., & Hummon, A. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16023537 · Cited by 288
Screening Mammography in Older Women: A Review
Walter, L. C., & Schonberg, M. A. (2014) · JAMA · doi:10.1001/jama.2014.2834 · Cited by 241
Wilke, L. G., Czechura, T., Wang, C., Lapin, B., Liederbach, E., Winchester, D. P., & Yao, K. (2014) · JAMA Surgery · doi:10.1001/jamasurg.2014.926 · Cited by 223
Quality indicators in breast cancer care: An update from the EUSOMA working group
Biganzoli, L., Marotti, L., Hart, C. D., Cataliotti, L., Cutuli, B., Kühn, T., Mansel, R. E., Ponti, A., Poortmans, P., Regitnig, P., et al. (2017) · European Journal of Cancer · doi:10.1016/j.ejca.2017.08.017 · Cited by 216
Metadata
- Authors
- Bruening, W., Fontanarosa, J., Tipton, K., Treadwell, J. R., Launders, J., & Schoelles, K.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2010-02-16
- Volume
- 152
- Issue
- 4
- Pages
- 238-246
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2101372881
- Cited by
- 251
- References
- 22
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.