CoChat

Sex Differences in Implantable Cardioverter-Defibrillator Outcomes: Findings From a Prospective Defibrillator Database

MacFadden, Derek R., Crystal, Eugene, Krahn, Andrew D., Mangat, Iqwal, Healey, Jeffrey S., Dorian, Paul, Birnie, David, Simpson, Christopher S., Khaykin, Yaariv, Pinter, Arnold, Nanthakumar, Kumaraswamy, Calzavara, Andrew J., Austin, Peter C., Tu, Jack V., Lee, Douglas S. · 2012 · Annals of Internal Medicine
Cited by 146

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Sex differences in the use and outcomes of implantable cardioverter-defibrillators (ICDs) have not been fully studied. OBJECTIVE: To examine potential sex differences in ICD implantation and device outcomes. DESIGN: Health payer-mandated, prospective study of patients referred for ICD implantation, with comprehensive, longitudinal follow-up for complications, deaths, and device outcomes. SETTING: 18 ICD implantation and follow-up centers in Ontario, Canada. PATIENTS: 6021 patients (4733 men) referred for ICD implantation from February 2007 to July 2010. MEASUREMENTS: Multivariate-adjusted ICD implantation rate, complications up to day 45, multivariate-adjusted complications, device outcomes (including appropriate shocks and therapies), and deaths occurring during 1-year follow-up. RESULTS: Rates of ICD implantation were similar in men and women (relative risk, 0.99 [95% CI, 0.97 to 1.02]; P = 0.60). However, women were significantly more likely to experience major complications by 45 days (odds ratio, 1.78 [CI, 1.24 to 2.58]; P = 0.002) and 1 year (hazard ratio [HR], 1.91 [CI, 1.48 to 2.47]; P < 0.001) after implantation. Occurrence of any major or minor complication was also increased in women at both 45-day follow-up (odds ratio, 1.50 [CI, 1.12 to 2.00]; P = 0.006) and 1-year follow-up (HR, 1.55 [CI, 1.25 to 1.93]; P < 0.001). After implantation, women were less likely than men to receive appropriate ICD shock (HR, 0.69 [CI, 0.51 to 0.93]; P = 0.015) or appropriate therapy via shock or antitachycardia pacing (HR, 0.73 [CI, 0.59 to 0.90]; P = 0.003). Total mortality among defibrillator recipients did not differ between men and women (HR, 1.00 [CI, 0.64 to 1.55]; P = 0.99). LIMITATION: The differential effects of sex on prereferral events were not examined. CONCLUSION: Although ICD implantation rates were similar after referral to an electrophysiologist, women who underwent ICD implantation had greater risks for complications and were less likely to experience appropriate ICD-delivered therapies than men. PRIMARY FUNDING SOURCE: Canadian Institutes of Health Research and Ontario Ministry of Health and Long-Term Care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-156-3-201202070-00007

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 146

Metadata

Authors
MacFadden, D. R., Crystal, E., Krahn, A. D., Mangat, I., Healey, J. S., Dorian, P., Birnie, D., Simpson, C. S., Khaykin, Y., Pinter, A., Nanthakumar, K., Calzavara, A. J., Austin, P. C., Tu, J. V., & Lee, D. S.
Venue
Annals of Internal Medicine
Published
2012-02-07
Volume
156
Issue
3
Pages
195-203
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2053781987
Cited by
146
References
4
FWCI
8.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sex Differences in Implantable Cardioverter-Defibrillator Outcomes: Findings From a Prospective Defibrillator Database. https://app.cochat.ai/papers/10.7326/0003-4819-156-3-201202070-00007
The paper
MacFadden, D. R., Crystal, E., Krahn, A. D., Mangat, I., Healey, J. S., Dorian, P., Birnie, D., Simpson, C. S., Khaykin, Y., Pinter, A., Nanthakumar, K., Calzavara, A. J., Austin, P. C., Tu, J. V., & Lee, D. S. (2012). Sex Differences in Implantable Cardioverter-Defibrillator Outcomes: Findings From a Prospective Defibrillator Database. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-156-3-201202070-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.