Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record.

Heart Failure as a Complication of Hemodialysis Arteriovenous Fistula

AHEARN, DANIEL J., MAHER, JOHN F.·1972·Annals of Internal Medicine

Abstract

Two patients with Brescia-Cimino fistulas had congestive heart failure. The ultrasonic flowmeter was used to measure increasing fistula flow in both patients, and Branham's sign was elicited in one. Surgical revision of the fistulas resulted in clinical improvement. Congestive heart failure may occur as a result of the surgically created arteriovenous fistula. A pronounced fall in pulse rate when the fistula has been occluded and progressive rise in fistula flow as measured by the flowmeter should alert the physician to the need for surgical revision.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-77-2-201

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 171

Metadata

Authors
AHEARN, D. J., & MAHER, J. F.
Venue
Annals of Internal Medicine
Published
1972-08-01
Volume
77
Issue
2
Pages
201-204
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2057968072
Cited by
171
References
0
FWCI
15.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart Failure as a Complication of Hemodialysis Arteriovenous Fistula. https://app.cochat.ai/papers/10.7326/0003-4819-77-2-201
The paper
AHEARN, D. J., & MAHER, J. F. (1972). Heart Failure as a Complication of Hemodialysis Arteriovenous Fistula. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-77-2-201

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.