Practical Closed-Loop Insulin Delivery: A System for the Maintenance of Overnight Euglycemia and the Calculation of Basal Insulin Requirements in Insulin-Dependent Diabetics
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We evaluated a practical closed-loop system of insulin delivery consisting of hourly blood glucose determinations using glucose oxidase reagent strips and an intravenous infusion of insulin controlled by a commonly available controller. In 25 insulin-dependent diabetic subjects, this system was successful in achieving and maintaining near euglycemia (blood glucose, 101 +/- 2 mg/dL, mean +/- SE) in the fasting state between 0200 and 0800 hours. This system may be useful in the management of insulin-dependent diabetic patients in various hospital settings. Also, in 10 subjects treated subsequently using a continuous subcutaneous insulin infusion, the mean hourly insulin infusion rate using the described system correlated well (r = 0.92) with the optimal overnight basal rate needed during continous subcutaneous insulin infusion therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rizza, R. A., Gerich, J. E., Haymond, M. W., Westland, R. E., Hall, L. D., Clemens, A. H., & Service, F. J. (1980) · New England Journal of Medicine · doi:10.1056/nejm198012043032301 · Cited by 279
Cited by
Management of diabetes and hyperglycemia in hospitals.
Clement, S., Braithwaite, S. S., Magee, M. F., Ahmann, A., Smith, E. P., Schafer, R. G., Hirsch, I. B., & on behalf of the Diabetes in Hospitals Writing Committee (2004) · Diabetes Care · doi:10.2337/diacare.27.2.553 · Cited by 1,266
White, N. H., Skor, D. A., Cryer, P. E., Levandoski, L. A., Bier, D. M., & Santiago, J. V. (1983) · New England Journal of Medicine · doi:10.1056/nejm198303033080903 · Cited by 391
Self-citationShah, P., Vella, A., Basu, A., Basu, R., Schwenk, W. F., & Rizza, R. A. (2000) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.85.11.6993 · Cited by 368
A semiclosed-loop algorithm for the control of blood glucose levels in diabetics
Fisher, M. E. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68209 · Cited by 271
Gene Expression Profile in Skeletal Muscle of Type 2 Diabetes and the Effect of Insulin Treatment
Sreekumar, R., Halvatsiotis, P., Schimke, J. C., & Nair, K. S. (2002) · Diabetes · doi:10.2337/diabetes.51.6.1913 · Cited by 257
Metadata
- Authors
- WHITE, N. H., SKOR, D., & SANTIAGO, J. V.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1982-08-01
- Volume
- 97
- Issue
- 2
- Pages
- 210-213
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2034391708
- Cited by
- 108
- References
- 1
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Practical Closed-Loop Insulin Delivery: A System for the Maintenance of Overnight Euglycemia and the Calculation of Basal Insulin Requirements in Insulin-Dependent Diabetics. https://app.cochat.ai/papers/10.7326/0003-4819-97-2-210
- The paper
- WHITE, N. H., SKOR, D., & SANTIAGO, J. V. (1982). Practical Closed-Loop Insulin Delivery: A System for the Maintenance of Overnight Euglycemia and the Calculation of Basal Insulin Requirements in Insulin-Dependent Diabetics. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-97-2-210
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.