The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Benefits, Harms, and Cost-Effectiveness of Supplemental Ultrasonography Screening for Women With Dense Breasts
Open accessAbstract
BACKGROUND: Many states have laws requiring mammography facilities to tell women with dense breasts and negative results on screening mammography to discuss supplemental screening tests with their providers. The most readily available supplemental screening method is ultrasonography, but little is known about its effectiveness. OBJECTIVE: To evaluate the benefits, harms, and cost-effectiveness of supplemental ultrasonography screening for women with dense breasts. DESIGN: Comparative modeling with 3 validated simulation models. DATA SOURCES: Surveillance, Epidemiology, and End Results Program; Breast Cancer Surveillance Consortium; and medical literature. TARGET POPULATION: Contemporary cohort of women eligible for routine screening. TIME HORIZON: Lifetime. PERSPECTIVE: Payer. INTERVENTION: Supplemental ultrasonography screening for women with dense breasts after a negative screening mammography result. OUTCOME MEASURES: Breast cancer deaths averted, quality-adjusted life-years (QALYs) gained, biopsies recommended after a false-positive ultrasonography result, and costs. RESULTS OF BASE-CASE ANALYSIS: Supplemental ultrasonography screening after a negative mammography result for women aged 50 to 74 years with heterogeneously or extremely dense breasts averted 0.36 additional breast cancer deaths (range across models, 0.14 to 0.75), gained 1.7 QALYs (range, 0.9 to 4.7), and resulted in 354 biopsy recommendations after a false-positive ultrasonography result (range, 345 to 421) per 1000 women with dense breasts compared with biennial screening by mammography alone. The cost-effectiveness ratio was $325,000 per QALY gained (range, $112,000 to $766,000). Supplemental ultrasonography screening for only women with extremely dense breasts cost $246,000 per QALY gained (range, $74,000 to $535,000). RESULTS OF SENSITIVITY ANALYSIS: The conclusions were not sensitive to ultrasonography performance characteristics, screening frequency, or starting age. LIMITATION: Provider costs for coordinating supplemental ultrasonography were not considered. CONCLUSION: Supplemental ultrasonography screening for women with dense breasts would substantially increase costs while producing relatively small benefits. PRIMARY FUNDING SOURCE: National Cancer Institute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cost-Effectiveness in Health and Medicine
(1996) · doi:10.1093/oso/9780195108248.001.0001 · Cited by 7,193
Consequences of false-positive screening mammograms
Tosteson, A. N. A., Fryback, D. G., Hammond, C. S., Hanna, L. G., Grove, M. R., Brown, M., Wang, Q., Lindfors, K., & Pisano, E. D. (2014) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2014.981 · Cited by 217 · cited 3×
“Recent findings from the Digital Mammographic Imaging Screening Trial (39) QALY = quality-adjusted life-years.”
BackgroundInfluentialSelf-citation
Cited by
Ohuchi, N., Suzuki, A., Sobue, T., Kawai, M., Yamamoto, S., Zheng, Y.-F., Shiono, Y. N., Saito, H., Kuriyama, S., Tohno, E., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00774-6 · Cited by 616
Comstock, C. E., Gatsonis, C., Newstead, G. M., Snyder, B. S., Gareen, I. F., Bergin, J. T., Rahbar, H., Sung, J. S., Jacobs, C., Harvey, J. A., et al. (2020) · JAMA · doi:10.1001/jama.2020.0572 · Cited by 456
Breast Cancer Screening and Diagnosis: A Synopsis of the European Breast Guidelines
Schünemann, H. J., Lerda, D., Quinn, C., Follmann, M., Alonso-Coello, P., Rossi, P. G., Lebeau, A., Nyström, L., Broeders, M., Ioannidou-Mouzaka, L., et al. (2020) · Annals of Internal Medicine · doi:10.7326/m19-2125 · Cited by 286
Mandelblatt, J. S., Stout, N. K., Schechter, C. B., van den Broek, J. J., Miglioretti, D. L., Krapcho, M., Trentham-Dietz, A., Munoz, D., Lee, S. J., Berry, D. A., et al. (2016) · Annals of Internal Medicine · doi:10.7326/m15-1536 · Cited by 281
Self-citationPfob, A., Sidey-Gibbons, C., Barr, R. G., Duda, V., Alwafai, Z., Balleyguier, C., Clevert, D.-A., Fastner, S., Gomez, C., Goncalo, M., et al. (2022) · European Journal of Cancer · doi:10.1016/j.ejca.2022.09.018 · Cited by 27
Metadata
- Authors
- Sprague, B. L., Stout, N. K., Schechter, C., van Ravesteyn, N. T., Cevik, M., Alagoz, O., Lee, C. I., van den Broek, J. J., Miglioretti, D. L., Mandelblatt, J. S., de Koning, H. J., Kerlikowske, K., Lehman, C. D., & Tosteson, A. N. A.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2015-02-03
- Volume
- 162
- Issue
- 3
- Pages
- 157-166
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2125902772
- Cited by
- 217
- References
- 2
- FWCI
- 14.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.