Real-Time Use of Artificial Intelligence in Identification of Diminutive Polyps During Colonoscopy: A Prospective Study
Abstract
Background: Computer-aided diagnosis (CAD) for colonoscopy may help endoscopists distinguish neoplastic polyps (adenomas) requiring resection from nonneoplastic polyps not requiring resection, potentially reducing cost. Objective: To evaluate the performance of real-time CAD with endocytoscopes (×520 ultramagnifying colonoscopes providing microvascular and cellular visualization of colorectal polyps after application of the narrow-band imaging [NBI] and methylene blue staining modes, respectively). Design: Single-group, open-label, prospective study. (UMIN [University hospital Medical Information Network] Clinical Trial Registry: UMIN000027360). Setting: University hospital. Participants: 791 consecutive patients undergoing colonoscopy and 23 endoscopists. Intervention: Real-time use of CAD during colonoscopy. Measurements: CAD-predicted pathology (neoplastic or nonneoplastic) of detected diminutive polyps (≤5 mm) on the basis of real-time outputs compared with pathologic diagnosis of the resected specimen (gold standard). The primary end point was whether CAD with the stained mode produced a negative predictive value (NPV) of 90% or greater for identifying diminutive rectosigmoid adenomas, the threshold required to "diagnose-and-leave" nonneoplastic polyps. Best- and worst-case scenarios assumed that polyps lacking either CAD diagnosis or pathology were true- or false-positive or true- or false-negative, respectively. Results: Overall, 466 diminutive (including 250 rectosigmoid) polyps from 325 patients were assessed by CAD, with a pathologic prediction rate of 98.1% (457 of 466). The NPVs of CAD for diminutive rectosigmoid adenomas were 96.4% (95% CI, 91.8% to 98.8%) (best-case scenario) and 93.7% (CI, 88.3% to 97.1%) (worst-case scenario) with stained mode and 96.5% (CI, 92.1% to 98.9%) (best-case scenario) and 95.2% (CI, 90.3% to 98.0%) (worst-case scenario) with NBI. Limitation: Two thirds of the colonoscopies were conducted by experts who had each experienced more than 200 endocytoscopies; 186 polyps not assessed by CAD were excluded. Conclusion: Real-time CAD can achieve the performance level required for a diagnose-and-leave strategy for diminutive, nonneoplastic rectosigmoid polyps. Primary Funding Source: Japan Society for the Promotion of Science.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Previous studies on cadx systems for colonoscopy focused on assessing the performances of ai against the accuracy of physicians19,20,27–30, or against the criteria established by gastroenterology societies for implementing the technology in a clinical setting31–34.”
From Experimental evidence of effective human–AI collaboration in medical decision-making (2022) · cites this paper as [27]
In the citing paper
“Computer-aided diagnosis (CADx) systems based on artificial intelligence (AI) can help endoscopists in the optical diagnosis of colorectal polyps by predicting the histopathology.”
From Appropriate trust in artificial intelligence for the optical diagnosis of colorectal polyps: the role of human/artificial intelligence interaction (2024) · cites this paper as [5]
In the citing paper
“The stand-alone performance of CADx systems and comparisons of CADx performances with thresholds for clinical implementation have been evaluated and show promising results.[1][2][3][4][5][6][7]”
From Appropriate trust in artificial intelligence for the optical diagnosis of colorectal polyps: the role of human/artificial intelligence interaction (2024) · cites this paper as [5]
Citations
Cites
A comparison of methods for multiclass support vector machines
Hsu, C., & Lin, C. (2002) · IEEE Transactions on Neural Networks · doi:10.1109/72.991427 · Cited by 6,923
Long-term colorectal-cancer incidence and mortality after lower endoscopy
Nishihara, R., Wu, K., Lochhead, P., Morikawa, T., Liao, X., Qian, Z. R., Inamura, K., Kim, S. A., Kuchiba, A., Yamauchi, M., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1301969 · Cited by 1,483
Lai, E. J., Calderwood, A. H., Doros, G. D., Fix, O. K., & Jacobson, B. C. (2009) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.05.057 · Cited by 1,322
Byrne, M. F., Chapados, N., Soudan, F., Oertel, C., Linares Pérez, M., Kelly, R., Iqbal, N., Chandelier, F., & Rex, D. K. (2019) · Gut · doi:10.1136/gutjnl-2017-314547 · Cited by 635
Rex, D. K., Kahi, C., O'Brien, M., Levin, T. R., Pohl, H., Rastogi, A., Burgart, L., Imperiale, T., Ladabaum, U., Cohen, J., et al. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.01.023 · Cited by 629
Accurate Classification of Diminutive Colorectal Polyps Using Computer-Aided Analysis
Chen, P., Lin, M.-C., Lai, M.-J., Lin, J.-C., Lu, H. H., & Tseng, V. S. M. (2017) · Gastroenterology · doi:10.1053/j.gastro.2017.10.010 · Cited by 396
Abu Dayyeh, B. K., Thosani, N., Konda, V., Wallace, M. B., Rex, D. K., Chauhan, S. S., Hwang, J. H., Komanduri, S., Manfredi, M., Maple, J. T., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.12.022 · Cited by 389
Competitive learning with floating-gate circuits
Hsu, D., Figueroa, M. E., & Diorio, C. (2002) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2002.1000139 · Cited by 382
Variation in the Detection of Serrated Polyps in an Average Risk Colorectal Cancer Screening Cohort
Hetzel, J. T., Huang, C. S., Coukos, J. A., Omstead, K., Cerda, S. R., Yang, S., O’Brien, M. J., & Farraye, F. A. (2010) · The American Journal of Gastroenterology · doi:10.1038/ajg.2010.315 · Cited by 335
Kominami, Y., Yoshida, S., Tanaka, S., Sanomura, Y., Hirakawa, T., Raytchev, B., Tamaki, T., Koide, T., Kaneda, K., & Chayama, K. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2015.08.004 · Cited by 250
Advanced endoscopic imaging: European Society of Gastrointestinal Endoscopy (ESGE) Technology Review
East, J. E., Vleugels, J. L. A., Roelandt, P. R., Bhandari, P., Bisschops, R., Dekker, E., Hassan, C., Horgan, G., Kießlich, R., Longcroft‐Wheaton, G., et al. (2016) · Endoscopy · doi:10.1055/s-0042-118087 · Cited by 238
Ladabaum, U., Fioritto, A., Mitani, A., Desai, M., Kim, J. P., Rex, D. K., Imperiale, T., & Gunaratnam, N. (2013) · Gastroenterology · doi:10.1053/j.gastro.2012.09.054 · Cited by 224
Rees, C. J., Rajasekhar, P. T., Wilson, A., Close, H., Rutter, M. D., Saunders, B. P., East, J. E., Maier, R., Moorghen, M., Muhammad, U., et al. (2017) · Gut · doi:10.1136/gutjnl-2015-310584 · Cited by 211
Evidence-based clinical practice guidelines for management of colorectal polyps
Tanaka, S., Saitoh, Y., Matsuda, T., Igarashi, M., Matsumoto, T., Iwao, Y., Suzuki, Y., Nishida, H., Watanabe, T., Sugai, T., et al. (2015) · Journal of Gastroenterology · doi:10.1007/s00535-014-1021-4 · Cited by 194
Misawa, M., Kudo, S., Mori, Y., Nakamura, H., Kataoka, S., Maeda, Y., Kudo, T., Hayashi, T., Wakamura, K., Miyachi, H., et al. (2016) · Gastroenterology · doi:10.1053/j.gastro.2016.04.004 · Cited by 174
Self-citationComputer-aided diagnosis for colonoscopy
Mori, Y., Kudo, S., Berzin, T. M., Misawa, M., & Takeda, K. (2017) · Endoscopy · doi:10.1055/s-0043-109430 · Cited by 158
Self-citationNovel computer-aided diagnostic system for colorectal lesions by using endocytoscopy (with videos)
Mori, Y., Kudo, S., Wakamura, K., Misawa, M., Ogawa, Y., Kutsukawa, M., Kudo, T., Hayashi, T., Miyachi, H., Ishida, F., et al. (2014) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.09.008 · Cited by 147
Self-citationGroß, S., Trautwein, C., Behrens, A., Winograd, R., Palm, S., Lutz, H. H., Schirin-Sokhan, R., Hecker, H., Aach, T., & Tischendorf, J. J. W. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.08.001 · Cited by 135
Mori, Y., Kudo, S., Chiu, P. W. Y., Singh, R., Misawa, M., Wakamura, K., Kudo, T., Hayashi, T., Katagiri, A., Miyachi, H., et al. (2016) · Endoscopy · doi:10.1055/s-0042-113609 · Cited by 112
Self-citationRäth, T., Tontini, G. E., Vieth, M. W., Nägel, A., Neurath, M. F., & Neumann, H. (2016) · Endoscopy · doi:10.1055/s-0042-102251 · Cited by 73
Tamai, N., Saito, Y., Sakamoto, T., Nakajima, T., Matsuda, T., Sumiyama, K., Tajiri, H., Koyama, R., & Kido, S. (2017) · Endoscopy International Open · doi:10.1055/s-0043-105490 · Cited by 59
Self-citationAutomatic optical diagnosis of small colorectal lesions by laser-induced autofluorescence
Kuiper, T., Alderlieste, Y. A., Tytgat, K. M. A. J., Vlug, M. S., Nabuurs, J. A., Bastiaansen, B. A. J., Löwenberg, M., Fockens, P., & Dekker, E. (2014) · Endoscopy · doi:10.1055/s-0034-1378112 · Cited by 50
European Society of Gastrointestinal Endoscopy (2026) · Endoscopy · doi:10.1055/s-00000012 · Cited by 45
Iwatate, M., Sano, Y., Hattori, S., Sano, W., Hasuike, N., Ikumoto, T., Kotaka, M., Murakami, Y., Hewett, D. G., Soetikno, R. M., et al. (2015) · Endoscopy International Open · doi:10.1055/s-0034-1391362 · Cited by 35
Singh, R., Cheong, K. L., Pu, L. Z. C. T., Mangira, D., Koay, D. S. C., Kee, C., Ng, S. C., Rerknimitr, R., Aniwan, S., Ang, T. L., et al. (2017) · World Journal of Gastrointestinal Endoscopy · doi:10.4253/wjge.v9.i6.273 · Cited by 14
Park, J.-K. (2026) · Endoscopy International Open · doi:10.1055/s-00025476 · Cited by 14
Endoscopic approach to polyp recognition
Lahiff, C. J., & East, J. E. (2017) · Frontline Gastroenterology · doi:10.1136/flgastro-2016-100777 · Cited by 12
Cited by
Sorted by citations
High-performance medicine: the convergence of human and artificial intelligence
Topol, E. J. (2019) · Nature Medicine · doi:10.1038/s41591-018-0300-7 · Cited by 10,450
Rajkomar, A., Dean, J., & Kohane, I. (2019) · New England Journal of Medicine · doi:10.1056/nejmra1814259 · Cited by 4,579
Key challenges for delivering clinical impact with artificial intelligence
Kelly, C. J., Karthikesalingam, A., Suleyman, M., Corrado, G., & King, D. (2019) · BMC Medicine · doi:10.1186/s12916-019-1426-2 · Cited by 3,136
Wang, P., Berzin, T. M., Glissen Brown, J. R., Bharadwaj, S., Becq, A., Xiao, X., Liu, P., Li, L., Song, Y., Zhang, D., et al. (2019) · Gut · doi:10.1136/gutjnl-2018-317500 · Cited by 865
Strategies for Colorectal Cancer Screening
Ladabaum, U., Dominitz, J. A., Kahi, C., & Schoen, R. E. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.06.043 · Cited by 696
Metadata
- Authors
- Mori, Y., Kudo, S.-E., Misawa, M., Saito, Y., Ikematsu, H., Hotta, K., Ohtsuka, K., Urushibara, F., Kataoka, S., Ogawa, Y., Maeda, Y., Takeda, K., Nakamura, H., Ichimasa, K., Kudo, T., Hayashi, T., Wakamura, K., Ishida, F., Inoue, H., Itoh, H., Oda, M., & Mori, K.
- Affiliations
- SHOWA Medical University Northern Yokohama Hospital (JP)
- National Cancer Center Hospital (JP)
- National Cancer Center Hospital East (JP)
- Shizuoka Cancer Center (JP)
- Tokyo Medical and Dental University (JP)
- SHOWA Medical University Koto Toyosu Hospital (JP)
- Nagoya University (JP)
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2018-09-18
- Volume
- 169
- Issue
- 6
- Pages
- 357-366
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2887719255
- Cited by
- 509
- References
- 27
- Citations by year
- 2026: 26 · 2025: 53 · 2024: 45 · 2023: 68 · 2022: 65 · 2021: 98 · 2020: 101 · 2019: 43 · 2018: 9
- FWCI
- 23.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annals of Internal Medicine (publishedVersion, public-domain)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (26108006, 26108001, 17H05305, 17K15971)
- Topics
- Health Sciences › Medicine › Oncology › Colorectal Cancer Screening and Detection
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Health Sciences › Medicine › Oncology › Colorectal Cancer Surgical Treatments
- Keywords
- computer-aided diagnosis, colonoscopy, narrow-band imaging, methylene blue staining, negative predictive value, polypectomy, real-time image analysis, colorectal cancer screening
- MeSH terms
- Adenoma, Aged, Artificial Intelligence, Colonic Polyps, Colonoscopy, Diagnosis, Computer-Assisted, Coloring Agents, Feasibility Studies, Female, Humans, Male, Methylene Blue, Middle Aged, Prospective Studies, Sensitivity and Specificity, Narrow Band Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review