CoChat

Single-protein detection in crowded molecular environments in cryo-EM images

Open access
Rickgauer, J Peter, Grigorieff, Nikolaus, Denk, Winfried · 2017 · eLife
Cited by 105

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We present an approach to study macromolecular assemblies by detecting component proteins’ characteristic high-resolution projection patterns, calculated from their known 3D structures, in single electron cryo-micrographs. Our method detects single apoferritin molecules in vitreous ice with high specificity and determines their orientation and location precisely. Simulations show that high spatial-frequency information and—in the presence of protein background—a whitening filter are essential for optimal detection, in particular for images taken far from focus. Experimentally, we could detect small viral RNA polymerase molecules, distributed randomly among binding locations, inside rotavirus particles. Based on the currently attainable image quality, we estimate a threshold for detection that is 150 kDa in ice and 300 kDa in 100 nm thick samples of dense biological material.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7554/elife.25648

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 42

  1. Al-Amoudi, 2007, The molecular architecture of cadherins in native epidermal desmosomes, Nature, 450, 832, 10.1038/nature05994 · DOI · Paper page
  2. Asano, 2016, In situ cryo-electron tomography: a post-reductionist approach to structural biology, Journal of Molecular Biology, 428, 332, 10.1016/j.jmb.2015.09.030 · DOI · Paper page
  3. Asano, 2015, Proteasomes. A molecular census of 26S proteasomes in intact neurons, Science, 347, 439, 10.1126/science.1261197 · DOI · Paper page
  4. Brandmann, 2015, Crystal structure of the C-terminal 2',5'-phosphodiesterase domain of group A Rotavirus protein VP3, Proteins: Structure, Function, and Bioinformatics, 83, 997, 10.1002/prot.24794 · DOI
  5. Breedlove, 1970, Molecular microscopy: fundamental limitations, Science, 170, 1310, 10.1126/science.170.3964.1310 · doi:10.1126/science.170.3964.1310
  6. Brilot, 2012, Beam-induced motion of vitrified specimen on holey carbon film, Journal of Structural Biology, 177, 630, 10.1016/j.jsb.2012.02.003 · DOI · Paper page
  7. Estrozi, 2013, Location of the dsRNA-dependent polymerase, VP1, in Rotavirus particles, Journal of Molecular Biology, 425, 124, 10.1016/j.jmb.2012.10.011 · doi:10.1016/j.jmb.2012.10.011
  8. Frangakis, 2002, Identification of macromolecular complexes in cryoelectron tomograms of phantom cells, PNAS, 99, 14153, 10.1073/pnas.172520299 · DOI · Paper page
  9. Frank, 1975, Signal-to-noise ratio of electron micrographs obtained by cross correlation, Nature, 256, 376, 10.1038/256376a0 · DOI · Paper page
  10. Glaeser, 1978, Radiation damage relative to transmission electron microscopy of biological specimens at low temperature: a review, Journal of Microscopy, 112, 127, 10.1111/j.1365-2818.1978.tb01160.x · doi:10.1111/j.1365-2818.1978.tb01160.x
  11. Glaeser, 2008, Retrospective: radiation damage and its associated "information limitations", Journal of Structural Biology, 163, 271, 10.1016/j.jsb.2008.06.001 · DOI
  12. Grant, 2015, Measuring the optimal exposure for single particle cryo-EM using a 2.6 Å reconstruction of rotavirus VP6, eLife, 4, e06980, 10.7554/eLife.06980 · DOI · Paper page
  13. Gridley, 2014, Regulation of Rotavirus polymerase activity by inner capsid proteins, Current Opinion in Virology, 9, 31, 10.1016/j.coviro.2014.08.008 · doi:10.1016/j.coviro.2014.08.008
  14. Grigorieff, 1998, Three-dimensional structure of Bovine NADH:ubiquinone oxidoreductase (complex I) at 22 A in ice, Journal of Molecular Biology, 277, 1033, 10.1006/jmbi.1998.1668 · DOI · Paper page
  15. Grigorieff, 2000, Resolution measurement in structures derived from single particles, Acta Crystallographica Section D Biological Crystallography, 56, 1270, 10.1107/S0907444900009549 · DOI · Paper page
  16. Grigorieff, 2007, FREALIGN: high-resolution refinement of single particle structures, Journal of Structural Biology, 157, 117, 10.1016/j.jsb.2006.05.004 · DOI · Paper page
  17. Grünewald, 2003, Prospects of electron cryotomography to visualize macromolecular complexes inside cellular compartments: implications of crowding, Biophysical Chemistry, 100, 577, 10.1016/S0301-4622(02)00307-1 · DOI
  18. Henderson, 1995, The potential and limitations of neutrons, electrons and X-rays for atomic resolution microscopy of unstained biological molecules, Quarterly Reviews of Biophysics, 28, 171, 10.1017/S003358350000305X · DOI · Paper page
  19. Henderson, 2013, Avoiding the pitfalls of single particle cryo-electron microscopy: Einstein from noise, PNAS, 110, 18037, 10.1073/pnas.1314449110 · DOI · Paper page
  20. Huang, 2004, Application of template matching technique to particle detection in electron micrographs, Journal of Structural Biology, 145, 29, 10.1016/j.jsb.2003.11.004 · DOI
  21. Levoy, 1992, Volume rendering using the Fourier projection-slice theorem, Graphics Interface, 92, 61, 10.20380/GI1992.08 · DOI
  22. Li, 2013, Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM, Nature Methods, 10, 584, 10.1038/nmeth.2472 · DOI · Paper page
  23. Li, 2013, Influence of electron dose rate on electron counting images recorded with the K2 Camera, Journal of Structural Biology, 184, 251, 10.1016/j.jsb.2013.08.005 · DOI
  24. Mastronarde, 2005, Automated electron microscope tomography using robust prediction of specimen movements, Journal of Structural Biology, 152, 36, 10.1016/j.jsb.2005.07.007 · DOI · Paper page
  25. McDonough, 1995, Detection of Signals in Noise
  26. McIlwain, 1985, Biochemistry and the Central Nervous System
  27. Ogden, 2015, Structural basis for 2′-5′-oligoadenylate binding and enzyme activity of a viral RNase L antagonist, Journal of Virology, 89, 6633, 10.1128/JVI.00701-15 · DOI
  28. Ogden, 2014, Predicted structure and domain organization of rotavirus capping enzyme and innate immune antagonist VP3, Journal of Virology, 88, 9072, 10.1128/JVI.00923-14 · DOI
  29. Oikonomou, 2016, A new view into prokaryotic cell biology from electron cryotomography, Nature Reviews Microbiology, 14, 205, 10.1038/nrmicro.2016.7 · DOI
  30. Ortiz, 2006, Mapping 70S ribosomes in intact cells by cryoelectron tomography and pattern recognition, Journal of Structural Biology, 156, 334, 10.1016/j.jsb.2006.04.014 · DOI
  31. Penczek, 1992, Three-dimensional reconstruction of single particles embedded in ice, Ultramicroscopy, 40, 33, 10.1016/0304-3991(92)90233-A · DOI · Paper page
  32. Pfeffer, 2015, Organization of the mitochondrial translation machinery studied in situ by cryoelectron tomography, Nature Communications, 6, 6019, 10.1038/ncomms7019 · DOI · Paper page
  33. Reimer, 2008, Transmission Electron Microscopy: Physics of Image Formation
  34. Rohou, 2015, CTFFIND4: Fast and accurate defocus estimation from electron micrographs, Journal of Structural Biology, 192, 216, 10.1016/j.jsb.2015.08.008 · DOI · Paper page
  35. Rullgard, 2011, Simulation of transmission electron microscope images of biological specimens, Journal of Microscopy, 243, 234, 10.1111/j.1365-2818.2011.03497.x · DOI
  36. Ruskin, 2013, Quantitative characterization of electron detectors for transmission electron microscopy, Journal of Structural Biology, 184, 385, 10.1016/j.jsb.2013.10.016 · DOI · Paper page
  37. Saff, 1997, Distributing many points on a sphere, The Mathematical Intelligencer, 19, 5, 10.1007/BF03024331 · DOI · Paper page
  38. Saxton, 1976, Motif detection in quantum noise-limited electron micrographs by cross-correlation, Ultramicroscopy, 2, 219, 10.1016/S0304-3991(76)91385-1 · doi:10.1016/s0304-3991(76)91385-1
  39. Sigworth, 2004, Classical detection theory and the cryo-EM particle selection problem, Journal of Structural Biology, 145, 111, 10.1016/j.jsb.2003.10.025 · doi:10.1016/j.jsb.2003.10.025
  40. Unser, 1987, A new resolution criterion based on spectral signal-to-noise ratios, Ultramicroscopy, 23, 39, 10.1016/0304-3991(87)90225-7 · DOI · Paper page
  41. Vulović, 2013, Image formation modeling in cryo-electron microscopy, Journal of Structural Biology, 183, 19, 10.1016/j.jsb.2013.05.008 · DOI
  42. Yershova, 2010, Generating Uniform Incremental Grids on SO(3) Using the Hopf Fibration, The International Journal of Robotics Research, 29, 801, 10.1177/0278364909352700 · DOI · Paper page

Cited by

See all 105

Metadata

Authors
Rickgauer, J. P., Grigorieff, N., & Denk, W.
Venue
eLife
Published
2017-05-03
Volume
6
ISSN
2050-084X (ISSN-L)
OpenAlex
W2611333828
Cited by
105
References
3
FWCI
3.08
Type
journal article
Language
en
Open access
gold
Funders
Howard Hughes Medical Institute (Internal)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Single-protein detection in crowded molecular environments in cryo-EM images. https://app.cochat.ai/papers/10.7554/elife.25648
The paper
Rickgauer, J. P., Grigorieff, N., & Denk, W. (2017). Single-protein detection in crowded molecular environments in cryo-EM images. eLife. https://doi.org/10.7554/elife.25648

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.