CoChat

The Measurement of Flash Point of Water-Methanol and Water-Ethanol Systems Using Seta Flash Closed Cup Tester

Open access
Ha, Dong-Myeong, Park, Sang Hun, Lee, Sungjin · 2015 · Fire Science and Engineering

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index; none of the 15 sources its claims cite is checked for support yet.

Abstract

인화점은 액체 혼합물의 화재와 폭발의 위험성을 특징짓는 주된 성질이다. 인화점은 가연성 액체에 불꽃이 가해졌을 때 점화가 발생하는 가장 낮은 온도로 정의된다. Seta flash 밀폐식 장치를 이용하여 이성분계 수용성 혼합물인 water-methanol계와 water-ethanol계의 인화점을 측정하였다. Wilson 식과 UNIQUAC 식과 같은 활동도 모델식을 활용한 방법을 이용하여 인화점을 계산하였다. 이 계산치와 라울의 법칙에 의한 계산치를 비교하였다. 그 결과, 활동도 계수 모델식에 의한 계산치가 라울의 법칙에 의한 계산치 보다 측정값에 보다 근접하였다. The flash point is the major property to characterize fire and explosion hazard of liquid mixtures. The flash point is the lowest temperature at which a liquid gives off enough vapor to form a flammable air-vapor mixture. The flash points of two aqueous mixtures, water-methanol and water-ethanol, were measured using Seta flash closed cup tester. A prediction method based on activity coefficient models, Wilson and UNIQUAC equations, was used to calculate the flash point. The calculated flash points were compared to the results by the calculating method using Raoult's law. The calculated values based on activity coefficients models were found to be better than those based on the Raoult's law.

Overview

CoChat Summary

TL;DR

Flash points of water-methanol and water-ethanol binary mixtures were measured with a Seta flash closed cup tester and compared with predictions from Wilson, UNIQUAC, and Raoult’s law. Activity-coefficient models matched experiments much better than Raoult’s law, with UNIQUAC giving the lowest average absolute errors for both systems.

Key findings

  • Water, a non-flammable component, inhibited flashing; higher water mole fraction raised the flash point. For water-methanol, experimental flash points rose from 10.0°C for pure methanol to 58.0°C at x_water = 0.950; for water-ethanol, from 12.0°C for pure ethanol to 43.0°C at x_water = 0.950.
  • For water-methanol, average absolute errors (AAEs) were 1.47°C for Wilson, 0.85°C for UNIQUAC, and 8.66°C for Raoult’s law.
  • For water-ethanol, AAEs were 2.53°C for Wilson, 1.54°C for UNIQUAC, and 11.98°C for Raoult’s law.
  • The activity coefficient method was more accurate than Raoult’s law and was concluded to be useful for calculating flash points of binary aqueous mixtures and analyzing fire/explosion hazards.

Methods

  • Two binary aqueous solutions, water-methanol and water-ethanol, were used. Methanol and ethanol were from CARLO Erba Reagents (Italy) with minimum purity 99.9%; water was HPLC grade from J.T. Baker, USA; all chemicals were used without purification.
  • Flash points were measured using a Seta flash closed cup tester manufactured by Koehler Instrument Company (USA), operated according to ASTM D 3278.
  • Flash points were calculated using vapor-liquid equilibrium relations, the Clausius-Clapeyron equation, and the Watson equation for enthalpy of vaporization; activity coefficients were calculated with Wilson and UNIQUAC equations using literature binary parameters, and results were compared with Raoult’s law. AAE was used to compare calculated and experimental flash points.

Limitations

  • Stated in the paper: experimental flash point data for liquid mixtures are scarce, especially for mixtures with non-flammable components such as water, and existing data were inconsistent; obtaining closed-cup flash point data is time-consuming and costly.
  • Evident from the text: only two binary systems and seven compositions per system were tested; no replicate measurements or uncertainty estimates are reported; Wilson and UNIQUAC predictions depend on binary interaction parameters taken from literature.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.7731/kifse.2015.29.2.039

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 0 Not valid · 13 Not checked · 15 Own results and interpretations

8 more claims

Create a free account to see all 28 claims and to verify the 15 references still open.

See all claims — free account
  • It may state two separate claims as one. 5
  • Probably not a substantial claim. 11

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Research works printed but not linked: 2

  1. D. White, C. L. Beyler and C. Fulper, "Flame Spread on Aviation Fuels", Fire Safety Journal, Vol. 28, pp. 1-31 (1997). · DOI · Paper page
  2. C. R. Reid, J. M. Prausnitz and B. E. Poling, "The Prop- erties of Gases and Liquids", 4nd ed., McGraw-Hill, New York (1998).

Cited by

See all 4

Metadata

Authors
Ha, D.-M., Park, S. H., & Lee, S.
Affiliations
Semyung University (KR)
Venue
Fire Science and Engineering
Published
2015-04-30
Volume
29
Issue
2
Pages
39-43
ISSN
1738-7167 (ISSN-L)
OpenAlex
W1831019340
Cited by
4
References
15
Citations by year
2021: 3 · 2019: 1
FWCI
0.00
Type
journal article
Language
en
Open access
Locations
Fire science and engineering (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Phase Equilibria and Thermodynamics
  • Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Thermodynamic properties of mixtures
  • Physical Sciences › Chemistry › Organic Chemistry › Chemical Thermodynamics and Molecular Structure
Keywords
flash point, methanol-water mixtures, ethanol-water mixtures, aqueous mixtures, activity coefficient models, Wilson equation, UNIQUAC equation, Raoult's law, flash point prediction, flammability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.