The Measurement of Flash Point of Water-Methanol and Water-Ethanol Systems Using Seta Flash Closed Cup Tester
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index; none of the 15 sources its claims cite is checked for support yet.
Abstract
인화점은 액체 혼합물의 화재와 폭발의 위험성을 특징짓는 주된 성질이다. 인화점은 가연성 액체에 불꽃이 가해졌을 때 점화가 발생하는 가장 낮은 온도로 정의된다. Seta flash 밀폐식 장치를 이용하여 이성분계 수용성 혼합물인 water-methanol계와 water-ethanol계의 인화점을 측정하였다. Wilson 식과 UNIQUAC 식과 같은 활동도 모델식을 활용한 방법을 이용하여 인화점을 계산하였다. 이 계산치와 라울의 법칙에 의한 계산치를 비교하였다. 그 결과, 활동도 계수 모델식에 의한 계산치가 라울의 법칙에 의한 계산치 보다 측정값에 보다 근접하였다. The flash point is the major property to characterize fire and explosion hazard of liquid mixtures. The flash point is the lowest temperature at which a liquid gives off enough vapor to form a flammable air-vapor mixture. The flash points of two aqueous mixtures, water-methanol and water-ethanol, were measured using Seta flash closed cup tester. A prediction method based on activity coefficient models, Wilson and UNIQUAC equations, was used to calculate the flash point. The calculated flash points were compared to the results by the calculating method using Raoult's law. The calculated values based on activity coefficients models were found to be better than those based on the Raoult's law.
Overview
CoChat Summary
TL;DR
Flash points of water-methanol and water-ethanol binary mixtures were measured with a Seta flash closed cup tester and compared with predictions from Wilson, UNIQUAC, and Raoult’s law. Activity-coefficient models matched experiments much better than Raoult’s law, with UNIQUAC giving the lowest average absolute errors for both systems.
Key findings
- Water, a non-flammable component, inhibited flashing; higher water mole fraction raised the flash point. For water-methanol, experimental flash points rose from 10.0°C for pure methanol to 58.0°C at x_water = 0.950; for water-ethanol, from 12.0°C for pure ethanol to 43.0°C at x_water = 0.950.
- For water-methanol, average absolute errors (AAEs) were 1.47°C for Wilson, 0.85°C for UNIQUAC, and 8.66°C for Raoult’s law.
- For water-ethanol, AAEs were 2.53°C for Wilson, 1.54°C for UNIQUAC, and 11.98°C for Raoult’s law.
- The activity coefficient method was more accurate than Raoult’s law and was concluded to be useful for calculating flash points of binary aqueous mixtures and analyzing fire/explosion hazards.
Methods
- Two binary aqueous solutions, water-methanol and water-ethanol, were used. Methanol and ethanol were from CARLO Erba Reagents (Italy) with minimum purity 99.9%; water was HPLC grade from J.T. Baker, USA; all chemicals were used without purification.
- Flash points were measured using a Seta flash closed cup tester manufactured by Koehler Instrument Company (USA), operated according to ASTM D 3278.
- Flash points were calculated using vapor-liquid equilibrium relations, the Clausius-Clapeyron equation, and the Watson equation for enthalpy of vaporization; activity coefficients were calculated with Wilson and UNIQUAC equations using literature binary parameters, and results were compared with Raoult’s law. AAE was used to compare calculated and experimental flash points.
Limitations
- Stated in the paper: experimental flash point data for liquid mixtures are scarce, especially for mixtures with non-flammable components such as water, and existing data were inconsistent; obtaining closed-cup flash point data is time-consuming and costly.
- Evident from the text: only two binary systems and seven compositions per system were tested; no replicate measurements or uncertainty estimates are reported; Wilson and UNIQUAC predictions depend on binary interaction parameters taken from literature.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 13 Not checked · 15 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“As can be seen from the figures, the non-flammable component (water) inhibits the flash.”
§ The Measurement of Flash Point of Water-Methanol and Water-Ethanol Systems Using Seta Flash Closed Cup Tester > 4.1 Experimental results
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The flash points for two systems, water-methanol and waterethanol, were measured using Seta flash closed cup tester.”
- Also stated in: § 5. Conclusion · plain
“The flash points for two aqueous mixtures, water-methanol and water-ethanol, were determined using Seta flash closed cup tester.”
§ The Measurement of Flash Point of Water-Methanol and Water-Ethanol Systems Using Seta Flash Closed Cup Tester > 1. Introduction
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § 5. Conclusion · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The AAE of the results calculated by the method based on Raoult's law is also 11.98 o C.”
§ The Measurement of Flash Point of Water-Methanol and Water-Ethanol Systems Using Seta Flash Closed Cup Tester > 4.2 The comparison of the experimental and calculated flash point
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“the AAEs between the experimental data and the results calculated by the methods using the Wilson and UNIQUAC equations are 2.53 o C and 1.54 o C, respectively.”
§ The Measurement of Flash Point of Water-Methanol and Water-Ethanol Systems Using Seta Flash Closed Cup Tester > 4.2 The comparison of the experimental and calculated flash point
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The AAEs of the results calculated by the methods using the Wilson and UNIQUAC equations are 1.47 o C and 0.85 o C, respectively.”
§ The Measurement of Flash Point of Water-Methanol and Water-Ethanol Systems Using Seta Flash Closed Cup Tester > 4.2 The comparison of the experimental and calculated flash point
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
8 more claims
Create a free account to see all 28 claims and to verify the 15 references still open.
- It may state two separate claims as one. 5
- Probably not a substantial claim. 11
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ The Measurement of Flash Point of Water-Methanol and Water-Ethanol Systems Using Seta Flash Closed Cup Tester > References
“4. D. White, C. L. Beyer, C. Fulper and J. Leonard, "Flame Spread on Aviation Fuels", Fire Safety Journal, Vol. 28, No. 1, pp. 1-23 (1997).”
§ The Measurement of Flash Point of Water-Methanol and Water-Ethanol Systems Using Seta Flash Closed Cup Tester > References
“7. D. White, C. L. Beyler and C. Fulper, "Flame Spread on Aviation Fuels", Fire Safety Journal, Vol. 28, pp. 1-31 (1997).”
Citations
Cites
The Properties of Gases and Liquids
Reid, R. C., Sherwood, T. K., & Street, R. E. (1959) · Physics Today · doi:10.1063/1.3060771 · Cited by 14,143
Vapor-Liquid Equilibrium Data Collection
Gmehling, J. (1977) · Cited by 1,228
A mathematical model for predicting the flash point of binary solutions
Liaw, H.-J., Lee, Y.-H., Tang, C.-L., Hsu, H.-H., & Liu, J.-H. (2002) · Journal of Loss Prevention in the Process Industries · doi:10.1016/s0950-4230(02)00068-2 · Cited by 129
Flammability properties of hydrocarbon solutions in air
Affens, W. A., & McLaren, G. W. (1972) · Journal of Chemical & Engineering Data · doi:10.1021/je60055a040 · Cited by 93
Flame spread on aviation fuels
White, D., Beyler, C. L., Fulper, C., & Leonard, J. (1997) · Fire Safety Journal · doi:10.1016/s0379-7112(96)00070-7 · Cited by 92
Prediction of miscible mixtures flash-point from UNIFAC group contribution methods
Liaw, H.-J., Gerbaud, V., & Li, Y.-H. (2011) · Fluid Phase Equilibria · doi:10.1016/j.fluid.2010.10.007 · Cited by 84
A Review of Flash Point Prediction Models for Flammable Liquid Mixtures
Phoon, L. Y., Mustaffa, A. A., Hashim, H., & Mat, R. (2014) · Industrial & Engineering Chemistry Research · doi:10.1021/ie501233g · Cited by 80
Zarringhalam Moghaddam, A., Rafiei, A., & Khalili, T. (2012) · Fluid Phase Equilibria · doi:10.1016/j.fluid.2011.12.014 · Cited by 44
Measurement of flash points: Apparatus, methodology, applications
Lance, R. C., Barnard, A. J., & Hooyman, J. E. (1979) · Journal of Hazardous Materials · doi:10.1016/0304-3894(79)85008-6 · Cited by 31
Measurement and calculation of flash point of binary aqueous–organic and organic–organic solutions
Khalili, T., & Moghaddam, A. Z. (2011) · Fluid Phase Equilibria · doi:10.1016/j.fluid.2011.09.003 · Cited by 20
Ha, D.-M., & Lee, S. (2011) · Korean Journal of Chemical Engineering · doi:10.1007/s11814-010-0478-y · Cited by 14
Self-citationShin, D., Kim, S.-Y., & Han, Y.-T. (2015) · Fire science and engineering · doi:10.7731/kifse.2015.29.2.044 · Cited by 12
A Preliminary Study on Vitalization Measures for Volunteer Fire Department Organizations
Seong-Cheon, W. (2015) · Fire science and engineering · doi:10.7731/kifse.2015.29.2.054 · Cited by 12
The Flash Point Measurement for Binary Flammable Mixture
Ha, D.-M., & Lee, S. (2014) · Journal of the Korean Institute of Gas · doi:10.7842/kigas.2014.18.5.60 · Cited by 4
Self-citationHa, D.-M., & Lee, S. (2014) · Journal of the Korean Society of Safety · doi:10.14346/jkosos.2014.29.6.076 · Cited by 1
Self-citation
Research works printed but not linked: 2
- D. White, C. L. Beyler and C. Fulper, "Flame Spread on Aviation Fuels", Fire Safety Journal, Vol. 28, pp. 1-31 (1997). · DOI · Paper page
- C. R. Reid, J. M. Prausnitz and B. E. Poling, "The Prop- erties of Gases and Liquids", 4nd ed., McGraw-Hill, New York (1998).
Cited by
The Use of Ethanol as an Alternative Fuel for Small Turbojet Engines
Andoga, R., Fözö, L., Schrötter, M., & Szabó, S. (2021) · Sustainability · doi:10.3390/su13052541 · Cited by 43
Spill Behavior, Detection, and Mitigation for Emerging Nontraditional Marine Fuels
Kass, M. D., USDOE Office of Science (SC), Sluder, C. S., & Kaul, B. C. (2021) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/2290266 · Cited by 21
Demonstration of Composition Changes in a Distillation Column by Use of Bromophenol Blue Indicator
Evjen, S., Petit, C., Hammer, M., Lindbråthen, A., Flatberg, G., Karolius, S., Presig, H., & Fiksdahl, A. (2019) · Journal of Chemical Education · doi:10.1021/acs.jchemed.8b00736 · Cited by 6
Hydrogen Production via Electroreforming
Colmati, F., Bastos, T. L., Lino, F. M. A. D., & Linares, J. J. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-819727-1.00052-2 · Cited by 3
Metadata
- Authors
- Ha, D.-M., Park, S. H., & Lee, S.
- Affiliations
- Semyung University (KR)
- Venue
- Fire Science and Engineering
- Published
- 2015-04-30
- Volume
- 29
- Issue
- 2
- Pages
- 39-43
- ISSN
- 1738-7167 (ISSN-L)
- OpenAlex
- W1831019340
- Cited by
- 4
- References
- 15
- Citations by year
- 2021: 3 · 2019: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Fire science and engineering (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Phase Equilibria and Thermodynamics
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Thermodynamic properties of mixtures
- Physical Sciences › Chemistry › Organic Chemistry › Chemical Thermodynamics and Molecular Structure
- Keywords
- flash point, methanol-water mixtures, ethanol-water mixtures, aqueous mixtures, activity coefficient models, Wilson equation, UNIQUAC equation, Raoult's law, flash point prediction, flammability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.