The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Novel Use of Apple Watch 4 to Obtain 3-Lead Electrocardiogram and Detect Cardiac Ischemia
Open accessAbstract
BACKGROUND: Early recognition and treatment of ST-elevation myocardial infarction (STEMI) results in better outcomes. OBJECTIVES: To describe a novel technique using the Apple Watch 4 (Apple Inc, Cupertino, CA) to obtain a 3-lead electrocardiogram (ECG) and confirm the watch's feasibility to detect cardiac ischemia in selective cases with a particular injury pattern. METHODS: Two male patients in the Emergency Department had STEMI apparent on their ECGs. These findings were compared with those from the Apple Watch 4, whose positioning was adjusted for 3-lead ECG. RESULTS: The patients' real-time, watch-based, 3-lead ECG tracings matched the traditional ECGs demonstrating STEMI, confirming the potential ability of this device to uncover myocardial ischemia. In each patient, cardiac catheterization revealed severe, 100% occlusion of the right coronary artery. CONCLUSION: The Apple Watch 4 could lead to earlier detection of acute coronary artery disease, but sensitivity and specificity remain unknown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Three-lead ECG tracings (as well as derived augmented limb leads) can be recorded with commercially available smartwatches (Avila 2019).8”
From 2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society (2021) · cites this paper as Avila 2019
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
WRITING COMMITTEE MEMBERS*, O’Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., et al. (2013) · Circulation · doi:10.1161/cir.0b013e3182742cf6 · Cited by 4,725
Finnegan, J. R., Meischke, H., Zapka, J. G., Leviton, L., Meshack, A., Benjamin-Garner, R., Estabrook, B., Hall, N. J., Schaeffer, S., Smith, C., et al. (2000) · Preventive Medicine · doi:10.1006/pmed.2000.0702 · Cited by 209
Dracup, K., Alonzo, A. A., Atkins, J. M., Bennett, N. M., Braslow, A., Clark, L. T., Eisenberg, M., Ferdinand, K. C., Frye, R., Green, L., et al. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-8-199704150-00010 · Cited by 198
Leslie, W. S., Urie, A., Hooper, J., & Morrison, C. E. (2000) · Heart · doi:10.1136/heart.84.2.137 · Cited by 188
Alonzo, A. A. (1986) · Social Science & Medicine · doi:10.1016/0277-9536(86)90093-6 · Cited by 150
Delay in Seeking Emergency Care
Rucker, D. W., Brennan, T. A., & Burstin, H. R. (2001) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2001.tb01282.x · Cited by 43
Supraventricular tachycardia diagnosed by smartphone ECG
Tabing, A. K., Harrell, T., Romero, S. C., & Francisco, G. M. (2017) · BMJ Case Reports · doi:10.1136/bcr-2016-217197 · Cited by 15
Crowd-Sourcing Syncope Diagnosis: Mobile Smartphone ECG Apps
Nyotowidjojo, I. S., Erickson, R. P., & Lee, K. S. S. (2015) · The American Journal of Medicine · doi:10.1016/j.amjmed.2015.11.022 · Cited by 4
Mobile digital health devices and the diagnosis in real-time of myocardial ischaemia
Joseph, J. P., & Redwood, S. R. (2017) · QJM · doi:10.1093/qjmed/hcx046 · Cited by 2
Research works printed but not linked: 4
- [1]Multiple cause of death files, 1999–2013, CDC WONDER [Internet] Atlanta, GA: Centers for Disease Control and Prevention; [cited 2015 Feb 3]. Available from: https://wonder.cdc.gov/mcd.html. [Google Scholar]
- [8]Campbell M. Apple shipped 9.2M Apple Watch units in Q4 2018 to capture half of market, report says [Internet] AppleInsider; 2019. Feb 27, [cited 2019 Apr 15]. Available from: https://appleinsider.com/articles/19/02/27/apple-shipped-92m-apple-watch-units-in-q4-2018-to-capture-half-of-market. [Google Scholar]
- [9]Taking an ECG with the ECG app on Apple Watch Series 4 [Internet] Cupertino, CA: Apple Support; 2019. Mar 27, [cited 2019 Apr 15]. Available from: https://support.apple.com/en-us/HT208955. [Google Scholar]
- [13]Apple Watch. Helping your patients identify early warning signs [Internet] Cupertino, CA: Apple Healthcare; [cited 2019 Apr 16]. Available from: www.apple.com/healthcare/apple-watch/ [Google Scholar]
Cited by
Smart Wearables for Cardiac Monitoring—Real-World Use beyond Atrial Fibrillation
Duncker, D., Ding, W. Y., Etheridge, S. P., Noseworthy, P. A., Veltmann, C., Yao, X., Bunch, T. J., & Gupta, D. (2021) · Sensors · doi:10.3390/s21072539 · Cited by 157
Multichannel Electrocardiograms Obtained by a Smartwatch for the Diagnosis of ST-Segment Changes
Spaccarotella, C., Polimeni, A., Migliarino, S., Principe, E., Curcio, A., Mongiardo, A., Sorrentino, S., Rosa, S. D., & Indolfi, C. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2020.3994 · Cited by 147
Samol, A., Bischof, K., Luani, B., Pascut, D., Wiemer, M., & Kaese, S. (2019) · Sensors · doi:10.3390/s19204377 · Cited by 129
Bouzid, Z., Al‐Zaiti, S. S., Bond, R., & Sejdić, E. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.02.030 · Cited by 115
The Use of Wearable ECG Devices in the Clinical Setting: A Review
Kamga, P., Mostafa, R., & Zafar, S. (2022) · Current Emergency and Hospital Medicine Reports · doi:10.1007/s40138-022-00248-x · Cited by 94
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
“…(Van Heuverswyn 2019).7 Three-lead ECG tracings (as well as derived augmented limb leads) can be recorded with commercially available smartwatches (Avila 2019).8 Limitations of this approach are the need for the patient or a bystander to possess the device or app and be familiar with its use,…”
MethodVarma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12795 · Cited by 54
Feasibility and Reliability of SmartWatch to Obtain 3-Lead Electrocardiogram Recordings
Behzadi, A., Shamloo, A. S., Mouratis, K., Hindricks, G., Arya, A., & Bollmann, A. (2020) · Sensors · doi:10.3390/s20185074 · Cited by 50
A Systematic Review on the Use of Consumer-Based ECG Wearables on Cardiac Health Monitoring
Wang, R., Veera, S. C. M., Asan, O., & Liao, T. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3456028 · Cited by 47
The use of smartwatch electrocardiogram beyond arrhythmia detection
Strik, M., Ploux, S., Weigel, D., van der Zande, J. L., Velraeds, A., Racine, H., Ramirez, F. D., Haïssaguerre, M., & Bordachar, P. (2023) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2022.12.006 · Cited by 46
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12461 · Cited by 39
Smart wearable model for predicting heart disease using machine learning
Rani, S. V. J., Chandran, K. R. S., Ranganathan, A., Chandrasekharan, M., Janani, B., & Deepsheka, G. (2022) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-022-03823-y · Cited by 42
Beyond the wrist: Using a smartwatch electrocardiogram to detect electrocardiographic abnormalities
Ploux, S., Strik, M., Caillol, T., Ramirez, F. D., Abu-Alrub, S., Marchand, H., Buliard, S., Haïssaguerre, M., & Bordachar, P. (2021) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2021.11.003 · Cited by 33
Use of wearables for monitoring cardiometabolic health: A systematic review
Lee, M. A., Song, M., Bessette, H. C., Davis, M. C., Tyner, T. E., & Reid, A. (2023) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2023.105218 · Cited by 35
Han, C., Song, Y.-J., Lim, H., Tae, Y., Jang, J.-H., Lee, B. T., Lee, Y., Bae, W., & Yoon, D. (2021) · Journal of Medical Internet Research · doi:10.2196/31129 · Cited by 35
Using a Smartwatch to Record Precordial Electrocardiograms: A Validation Study
van der Zande, J. L., Strik, M., Dubois, R., Ploux, S., Abu-Alrub, S., Caillol, T., Nasarre, M., Donker, D. W., Oppersma, E., & Bordachar, P. (2023) · Sensors · doi:10.3390/s23052555 · Cited by 30
The Reliability of the Apple Watch’s Electrocardiogram
Alnasser, S., Alkalthem, D., Alenazi, S., Alsowinea, M., Alanazi, N., & Fagih, A. R. A. (2023) · Cureus · doi:10.7759/cureus.49786 · Cited by 27
Li, K., Elgalad, A., Cardoso, C. D. O., & Perin, E. C. (2022) · Texas Heart Institute Journal · doi:10.14503/thij-22-7845 · Cited by 23
Choi, J., Kim, J., Spaccarotella, C., Esposito, G., Oh, I., Cho, Y., & Indolfi, C. (2024) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2024.101573 · Cited by 22
Smart devices to measure and monitor QT intervals
Hoek, L. J., Brouwer, J. L. P., Voors, A. A., & Maass, A. H. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1172666 · Cited by 21
Stark, K., Czermak, T., Maßberg, S., & Orban, M. (2020) · European Heart Journal - Case Reports · doi:10.1093/ehjcr/ytaa353 · Cited by 21
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab001 · Cited by 21
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2020.11.004 · Cited by 19
Paslı, S., Topçuoğlu, H., Yılmaz, M., Yadigaroğlu, M., İmamoğlu, M., & Karaca, Y. (2024) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2024.01.046 · Cited by 16
Enhancing Healthcare Access–Smartphone Apps in Arrhythmia Screening: Viewpoint
Książczyk, M., Dębska-Kozłowska, A., Warchoł, I., & Lubiński, A. (2021) · JMIR mhealth and uhealth · doi:10.2196/23425 · Cited by 16
Detection of acute coronary occlusion with a novel mobile electrocardiogram device: a pilot study
Zepeda-Echavarria, A., van de Leur, R. R., Vessies, M. B., de Vries, N. M., van Sleuwen, M., Hassink, R. J., Wildbergh, T. X., van Doorn, J. L., van der Zee, R., Doevendans, P. A., et al. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztae002 · Cited by 15
Intelligent health management based on analysis of big data collected by wearable smart watch
Chen, X., Yang, B., Zhao, S., Jie, D., Peng, S., & Gan, L. (2022) · Cognitive Robotics · doi:10.1016/j.cogr.2022.12.003 · Cited by 14
Smartwatch ECG Tracing and Ischemic Heart Disease: ACS Watch Study
Suárez, M. L. B., Izco, M. P., Pueyo, P. P., Granero, C. L., Montalvo, J. G., & Salinas, G. L. A. (2022) · Cardiology · doi:10.1159/000528116 · Cited by 13
van Es, V. A. A., Lathauwer, I. L. J. D., Kemps, H., Handjaras, G., & Betta, M. (2024) · Bioengineering · doi:10.3390/bioengineering11101045 · Cited by 12
Management for stroke intelligent early warning empowered by big data
Chen, X., Yang, B., Zhao, S., Wei, W., Chen, J., Ding, J., Wang, H., Sun, P., & Gan, L. (2023) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2023.108602 · Cited by 12
A review of patient-led data acquisition for atrial fibrillation detection to prevent stroke
Kareem, M., Lei, N., Ali, A., Ciaccio, E. J., Acharya, U. R., & Faust, O. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102818 · Cited by 10
Samol, A., Bischof, K., Luani, B., Pascut, D., Wiemer, M., & Kaese, S. (2019) · Journal of Visualized Experiments · doi:10.3791/60715 · Cited by 12
Mobile health technologies in cardiology
Belenkov, Y. N., & Kozhevnikova, M. V. (2022) · Kardiologiia · doi:10.18087/cardio.2022.1.n1963 · Cited by 10
A Scoping Review of Varying Mobile Electrocardiographic Devices
Dzikowicz, D. J. (2023) · Biological Research For Nursing · doi:10.1177/10998004231216923 · Cited by 9
IBSync: Intra-body Synchronization of Wearable Devices Using Artificial ECG Landmarks
Wolling, F., Huynh, C. D., & Laerhoven, K. V. (2021) · International Symposium on Wearable Computers · doi:10.1145/3460421.3478815 · Cited by 11
An IoT-based Smart Wearable E-Health Monitoring System for Patients with Heart Diseases
Abo-Zahhad, M. M. (2023) · MEJ Mansoura Engineering Journal · doi:10.58491/2735-4202.3079 · Cited by 8
Krasteva, V., Iliev, I. T., & Tabakov, S. D. (2024) · Sensors · doi:10.3390/s24061883 · Cited by 8
Multiscale dilated convolutional neural network for Atrial Fibrillation detection
Xia, L., He, S., Huang, Y.-F., & Ma, H. (2024) · PLoS ONE · doi:10.1371/journal.pone.0301691 · Cited by 7
Systematic Comparison of ECG Delineation Algorithm Performance on Smartwatch Data
Jaeger, K. M., Nissen, M., Flaucher, M., Graf, L. S., Joanidopoulos, J., Anneken, L., Huebner, H., Goossens, C., Titzmann, A., Pontones, C. A., et al. (2024) · IEEE Access · doi:10.1109/access.2024.3487013 · Cited by 7
Varma, N., Cygankiewicz, I., & Turakhia, M. P. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4420 · Cited by 7
Khundaqji, H., Hing, W. A., Furness, J. W., & Climstein, M. (2021) · PeerJ · doi:10.7717/peerj.12598 · Cited by 8
Feasibility of patch-type wireless 12-lead electrocardiogram in laypersons
Yoon, S., Kim, T., Kang, E., Heo, S., Chang, H., Seo, Y., & Cha, W. C. (2023) · Scientific Reports · doi:10.1038/s41598-023-31309-0 · Cited by 7
Smart Watch Detection of Supraventricular Tachycardia (SVT): First Case from Tanzania
Kassam, N., Aziz, O., Aghan, E., Somji, S., Mbithe, H., Bapumia, M., Mvungi, R., & Surani, S. (2021) · International Medical Case Reports Journal · doi:10.2147/imcrj.s328167 · Cited by 7
Goodings, A. J., Fadahunsi, K. P., Tarn, D. M., Lutomski, J. E., Chhor, A. D., Shiely, F., Henn, P., & O’Donoghue, J. (2025) · Journal of Medical Internet Research · doi:10.2196/67414 · Cited by 6
Kim, A. E., Chatterjee, M., Iansavitchene, A., Komeili, M., Chan, A. D. C., Yang, H., & Chui, J. (2025) · British Journal of Anaesthesia · doi:10.1016/j.bja.2025.05.037 · Cited by 8
Hernández, J. M. D. L. T., Ongay, A. G., Villarroel, T. B., Lizarbe, S. G., Fernández, G. V., Villa, S. C., Majado, B. D. T., González, M. L., Quirico, M. M. S., Lozano, D. S., et al. (2020) · REC CardioClinics · doi:10.1016/j.rccl.2020.07.005 · Cited by 6
Touiti, S., Medarhri, I., Marzouki, K., Ngote, N., & Tazi-Mezalek, A. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e20593 · Cited by 6
Goodings, A. J., Tarn, D. M., Fadahunsi, K. P., Henn, P., Shiely, F., & O’Donoghue, J. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-081228 · Cited by 6
LOW COST WIRELESS ECG PATCH USING ESP32
Sugandi, B., Satria, M. H., Arif, H., Nelmiawati, N., & Mulyadi, I. H. (2020) · JURNAL INTEGRASI · doi:10.30871/ji.v12i1.1764 · Cited by 6
Novel use of Apple Watch 4 to Obtain 3-lead Electrocardiogram and Detect Cardiac Ischemia
Gil, M. Á. C. (2020) · The Permanente Journal · doi:10.7812/tpp/19.202 · Cited by 6
Li, K., Morales‐Garza, M. A., Cardoso, C. D. O., Moctezuma-Ramirez, A., Burman, A., Titus, J., Elgalad, A., & Perin, E. C. (2023) · Diagnostics · doi:10.3390/diagnostics13061006 · Cited by 5
Smartwatch: Looking beyond what you see
Suárez, M. L. B., Sánchez, A. R., Izco, M. P., Montalvo, J. G., & Salinas, G. L. A. (2023) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2023.07.010 · Cited by 5
An augmented reality–based method to assess precordial electrocardiogram leads: a feasibility trial
Serfözö, P. D., Sandkühler, R., Blümke, B., Matthisson, E., Meier, J., Odermatt, J., Badertscher, P., Sticherling, C., Strebel, I., Cattin, P. C., et al. (2023) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztad046 · Cited by 5
Spotting myocardial ischemia on a smartwatch
Tyler, K. R., Mumma, B. E., Anderson, D. R., & Goldschlager, N. (2024) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2024.02.011 · Cited by 4
Kohli, M., Moore, D. J., & Moore, R. C. (2020) · AIDS · doi:10.1097/qad.0000000000002726 · Cited by 3
Wilkinson-Stokes, M. (2020) · Australasian Journal of Paramedicine · doi:10.33151/ajp.17.816 · Cited by 3
Shen, J., Chen, T., Lai, J., Yang, W., Xiu, J., Han, B., Shi, Y., Chen, Y., & Guo, J. (2022) · PubMed · doi:10.12122/j.issn.1673-4254.2022.10.18 · Cited by 3
Use of Smartphones and Wearables for Arrhythmia Monitoring
Sanders, D. J., Wasserlauf, J., & PASSMAN, R. S. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.04.004 · Cited by 4
Jung, S., Kang, I. S., Shin, S., Kim, C., & Park, J. (2024) · Medicina · doi:10.3390/medicina60071164 · Cited by 2
Hayama, E., Yamashita, T., Otsuka, T., Yagi, N., Arita, T., Yajima, J., & Suzuki, S. S. (2020) · Japanese Journal of Electrocardiology · doi:10.5105/jse.40.207 · Cited by 2
Commercial Non‐Invasive and Invasive Devices for Heart Failure Prediction
Kunhoth, J., Subramanian, N., & Bouridane, A. (2022) · Wiley eBooks · doi:10.1002/9781119813040.ch11 · Cited by 1
Wearable Devices and IoT: Advancing Continuous Health Monitoring and Management
Suciu, G. D., Stalidi, C., Carmen, M., Grecu, E., Popovici, E. C., Suciu, I., & Cosma, I. (2024) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb64556.2024.10805607 · Cited by 1
Ventricular arrhythmia detected by an Apple Watch – a case report
Galas, A. A., & Krzesiński, P. (2025) · Pediatria i Medycyna Rodzinna · doi:10.15557/pimr.2025.0010 · Cited by 1
Two Recently Described Methods of Recording Multi-Lead ECGs with an Apple Watch
Jerome, D. (2020) · Wilderness and Environmental Medicine · doi:10.1016/j.wem.2020.07.009
ECGT2T: Electrocardiogram synthesis from Two asynchronous leads to Ten leads.
Jo, Y., & Kwon, J. (2021)
¿Hay algún médico a bordo? Por favor, traiga su electrocardiógrafo
Gil, M. Á. C., & Ferrández-Escarabajal, M. (2021) · REC CardioClinics · doi:10.1016/j.rccl.2021.03.004
Electrocardiogram synthesisPreprint
Jo, Y., & Kwon, J. (2021) · arXiv (Cornell University)
HRnV-Calc: A software package for heart rate n-variability and heart rate variability analysisPreprint
Niu, C., Guo, D., Ong, M. E. H., Koh, Z. X., Ho, A. F. W., Lin, Z., Liu, C., Clifford, G. D., & Liu, N. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2111.09649
Smartwatches for Arrhythmia Detection and Management
Kim, C. H., Marvel, F. A., Majmudar, A., Horstman, N. A., SPRAGG, D. D., Calkins, H. G., Donnellan, E., Martin, S. S., & Isakadze, N. (2024) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-024-01040-8
Rhythm-Ready: Harnessing Smart Devices to Detect and Manage Arrhythmias
Hsieh, P. N., & Singh, J. P. (2024) · Current Cardiology Reports · doi:10.1007/s11886-024-02135-1
ten Broeke, J. E., Zepeda-Echavarria, A., van de Leur, R. R., Vessies, M. B., van der Meer, M. G., van Es, R., Hassink, R. J., Wildbergh, T. X., van der Zee, R., Zhang, Y., et al. (2025) · medRxiv · doi:10.1101/2025.06.03.25328866
Innovative Technologies: Optimizing Nursing Practice
Tiase, V. L., Martin, C. L., Bakker, C., Fink, S. S., Gao, G., Gopikrishnan, A. D., Lee, M. A., Lunt, C., Taylor-Pearson, K., Wyatt, T. H., et al. (2025) · CIN Computers Informatics Nursing · doi:10.1097/cin.0000000000001352 · Cited by 1
Pandey, C., Singh, Y., Pandey, S., Tomar, D., Chandola, N., Agarwal, D., & Singh, S. Y. P. (2025) · The Egyptian Heart Journal · doi:10.1186/s43044-025-00691-7
Puszkarski, B. (2026) · Physiological Measurement · doi:10.1088/1361-6579/ae8b71
Suárez, M. L. B., Plaza–Seco, C., Matía, R., Salinas, G. L. A., & Blanco–Velasco, M. (2026) · JMIR Cardio · doi:10.2196/86621
Metadata
- Authors
- Avila, C. O.
- Affiliations
- University of California San Diego Medical Center (US)
- Corresponding author
- Avila, Cesar O
- Venue
- The Permanente Journal
- Publisher
- The Permanente Federation
- Published
- 2019-09
- Volume
- 23
- Issue
- 3
- ISSN
- 1552-5767 (ISSN-L)
- 1552-5775
- PMC
- PMC6636475
- OpenAlex
- W2994767317
- Cited by
- 76
- References
- 9
- Citations by year
- 2025: 8 · 2024: 15 · 2023: 13 · 2022: 8 · 2021: 20 · 2020: 10 · 2019: 2
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Permanente Journal (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- ST-elevation myocardial infarction, wearable ECG, right coronary artery occlusion, acute coronary artery disease, emergency department diagnosis
- MeSH terms
- ST Elevation Myocardial Infarction, Wearable Electronic Devices, Aged, Electrocardiography, Humans, Male, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.