Computer-assisted evaluation of ultrasonic fetal weight prediction using multiple regression equations with and without the fetal femur length.
The DOI matches its Crossref record.
Abstract
Ultrasonic fetal femur length (FL) measurement provides an accurate fetal length. Combined with cross-sectional dimensions such as the biparietal diameter (BPD) and abdominal circumference (AC), FL provides a three-dimensional profile of the fetus. The usefulness of incorporating FL measurements into weight-predicting regression equations containing the BPD and AC was assessed. Multiple regression equations containing these three parameters as a function of log10 birthweight were constructed from data obtained from 125 patients within 48 hours of delivery. The mean errors in fetal weight prediction derived from five of these equations were assessed in another 92 patients. The coefficients of multiple correlation were marginally better in those equations that contained FL. The mean differences were also slightly lower with these equations compared with those that did not contain FL. However, the mean differences derived from all the equations were not significantly different from each other (P greater than 0.05). Therefore, despite theoretical considerations, the results from this study do not justify the routine clinical use of these new equations containing FL to estimate intrauterine fetal weight, in replacement of existing charts based on BPD and AC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Milner, J., & Arezina, J. (2018) · Ultrasound · doi:10.1177/1742271x17732807 · Cited by 174
Hammami, A., Mazer Zumaeta, A., Syngelaki, A., Akolekar, R., & Nicolaides, K. H. (2018) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.19066 · Cited by 170
“There are four papers reporting models for different combinations of measurements with and without FL; inclusion of FL improved the accuracy of the models in two,(26,29) and produced similar results in the other two.(16,27)”
BackgroundMethodResultInfluentialSonographic Fetal Weight Estimation: Which Model Should Be Used?
Melamed, N., Yogev, Y., Meizner, I., Mashiach, R., Bardin, R., & Ben-Haroush, A. (2009) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2009.28.5.617 · Cited by 112
“Models were subdivided into 7 model groups according to the combination of fetal biometric indices incorporated in each model (Table 1): (1) AC; (2) AC and FL; (3) AC and BPD; (4) AC and HC or AC, HC, and BPD; (5) AC, FL, and BPD; (6) AC, FL, and HC; and (7) AC, FL, BPD, and HC.”
MethodDavid, C., Tagliavini, G., Pilu, G., Rudenholz, A., & Bovicelli, L. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)70347-2 · Cited by 62
Yordan, J., Holbrook, B., Nirgudkar, P., Mozurkewich, E., & Blue, N. (2017) · American Journal of Perinatology · doi:10.1055/s-0037-1604059 · Cited by 41
Metadata
- Authors
- Woo, J. S., Wan, C. W., & Cho, K. M.
- Venue
- Journal of Ultrasound in Medicine
- Publisher
- Wiley
- Published
- 1985-02
- Volume
- 4
- Issue
- 2
- Pages
- 65-67
- ISSN
- 0278-4297 (ISSN-L)
- OpenAlex
- W1880287739
- Cited by
- 81
- References
- 0
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.