The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
The accuracy of ultrasound estimation of fetal weight in comparison to birth weight: A systematic review
Open accessAbstract
Ultrasound estimation of fetal weight is a highly influential factor in antenatal management, guiding both the timing and mode of delivery of a pregnancy. Although substantial research has investigated the most accurate ultrasound formula for calculating estimated fetal weight, current evidence indicates significant error levels. The aim of this systematic review was to identify the most accurate method, whilst identifying sources of inaccuracy in order to facilitate recommendations for future practice. Seven studies met the inclusion criteria and 11 different formulae were assessed; ultrasound calculation of fetal weight was most commonly overestimated. The Hadlock A formula produced the most accurate results, with the lowest levels of random error. Methods incorporating just two measurement parameters were inconsistent, producing large random errors across multiple studies. Key sources of inaccuracy included difficulties obtaining accurate fetal measurements in late gestation; the remainder were operator dependent, including lack of experience and insufficient training and audit. The accuracy of ultrasound estimated fetal weight has improved in the last decade, though a lack of consistency remains evident. National implementation of a rigorous audit programme would likely improve accuracy further, and increase the confidence and clinical value of the method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682
Maternal and fetal risk factors for stillbirth: population based study
Gardosi, J., Madurasinghe, V., Williams, M., Malik, A., & Francis, A. (2013) · BMJ · doi:10.1136/bmj.f108 · Cited by 941
A systematic review of the ultrasound estimation of fetal weight
Dudley, N. J. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1751 · Cited by 537
Sonographic Fetal Weight Estimation: Which Model Should Be Used?
Melamed, N., Yogev, Y., Meizner, I., Mashiach, R., Bardin, R., & Ben-Haroush, A. (2009) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2009.28.5.617 · Cited by 112
Cited by
Melamed, N., Baschat, A., Yinon, Y., Athanasiadis, A., Mecacci, F., Figueras, F., Berghella, V., Nazareth, A., Tahlak, M., McIntyre, H. D., et al. (2021) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.13522 · Cited by 570
Macrosomia: ACOG Practice Bulletin, Number 216
(2020) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000003606 · Cited by 331
Metadata
- Authors
- Milner, J., & Arezina, J.
- Venue
- Ultrasound
- Publisher
- SAGE Publications
- Published
- 2018-02
- Volume
- 26
- Issue
- 1
- Pages
- 32-41
- ISSN
- 0966-1905 (ISSN-L)
- 1742-271X
- 1743-1344
- OpenAlex
- W2789413961
- Cited by
- 174
- References
- 4
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The accuracy of ultrasound estimation of fetal weight in comparison to birth weight: A systematic review. https://app.cochat.ai/papers/10.1177/1742271x17732807
- The paper
- Milner, J., & Arezina, J. (2018). The accuracy of ultrasound estimation of fetal weight in comparison to birth weight: A systematic review. Ultrasound. https://doi.org/10.1177/1742271x17732807
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.