The DOI matches its Crossref record.
Ultrasonographic evaluation of diaphragmatic motion.
Abstract
To evaluate the technical feasibility and utility of ultrasonography in the study of diaphragmatic motion at our institution. The study consisted of 2 parts. For part I, in 23 volunteers we performed 23 studies on 46 hemidiaphragms with excursions documented on M‐mode ultrasonography For part II, in 22 patients we performed 52 studies in 102 hemidiaphragms. In 50 studies both hemidiaphragms were studied, and in another 2 studies only 1 hemidiaphragm was studied. Patients' ages ranged from birth to 66 years (mean, 23 years). There were 16 male and 6 female patients. Indications for the study were (1) suggestion of paralysis of the diaphragm (n = 22); (2) if the diaphragm was already known to be paralyzed, for evaluation of response to phrenic nerve or pacer stimulation (n = 9); and (3) follow‐up of previous findings (n = 21). Patients were examined in the supine position in the longitudinal semicoronal plane from a subcostal or low intercostal approach. Motion was documented with real‐time ultrasonography and measured with M‐mode ultrasonography. Of the 102 clinical hemidiaphragms studied, findings included normal motion (n = 42), decreased motion (n = 22), no motion (n = 6), paradoxical motion (n = 10), positive pacer response (n = 13), negative pacer response (n = 2), positive phrenic stimulation (n = 6), and negative phrenic stimulation (n = 1). There were no failures of visualization. Ultrasonography proved feasible and useful in evaluating diaphragmatic motion. In our practice it has replaced fluoroscopy. Ultrasonography has advantages over traditional fluoroscopy, including portability, lack of ionizing radiation, visualization of structures of the thoracic bases and upper abdomen, and the ability to quantify diaphragmatic motion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diaphragmatic Motion Studied by M-Mode Ultrasonography
Boussuges, A., Gole, Y., & Blanc, P. (2009) · Chest · doi:10.1378/chest.08-1541 · Cited by 760
Farghaly, S., & Hasan, A. A. (2017) · Australian Critical Care · doi:10.1016/j.aucc.2016.03.004 · Cited by 159
Singh, M., Tuteja, A., Wong, D. T., Goel, A., Trivedi, A., Tomlinson, G., & Chan, V. (2019) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004350 · Cited by 33
Metadata
- Authors
- Gerscovich, E. O., Cronan, M., McGahan, J. P., Jain, K., Jones, C. D., & McDonald, C.
- Venue
- Journal of Ultrasound in Medicine
- Publisher
- Wiley
- Published
- 2001-06
- Volume
- 20
- Issue
- 6
- Pages
- 597-604
- ISSN
- 0278-4297 (ISSN-L)
- 1550-9613
- OpenAlex
- W2150092938
- Cited by
- 312
- References
- 0
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasonographic evaluation of diaphragmatic motion. https://app.cochat.ai/papers/10.7863/jum.2001.20.6.597
- The paper
- Gerscovich, E. O., Cronan, M., McGahan, J. P., Jain, K., Jones, C. D., & McDonald, C. (2001). Ultrasonographic evaluation of diaphragmatic motion. Journal of Ultrasound in Medicine. https://doi.org/10.7863/jum.2001.20.6.597
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.