CoChat

Point-of-Care Ultrasound for Obstructive Sleep Apnea Screening: Are We There Yet? A Systematic Review and Meta-analysis

Open access
Singh, Mandeep, Tuteja, Arvind, Wong, David T., Goel, Akash, Trivedi, Aditya, Tomlinson, George, Chan, Vincent · 2019 · Anesthesia & Analgesia

The DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Perioperative diagnosis of obstructive sleep apnea (OSA) has important resource implications as screening questionnaires are overly sensitive, and sleep studies are expensive and time-consuming. Ultrasound (US) is a portable, noninvasive tool potentially useful for airway evaluation and OSA screening in the perioperative period. The objective of this systematic review was to evaluate the correlation of surface US with OSA diagnosis and to determine whether a point-of-care ultrasound (PoCUS) for OSA screening may help with improved screening in perioperative period. METHODS: A search of all electronic databases including Medline, Embase, and Cochrane Database of Systematic Reviews was conducted from database inception to September 2017. Inclusion criteria were observational cohort studies and randomized controlled trials of known or suspected OSA patients undergoing surface US assessment. Article screening, data extraction, and summarization were conducted by 2 independent reviewers with ability to resolve conflict with supervising authors. Diagnostic properties and association between US parameters (index test) and OSA diagnosis using sleep study (reference standard) were evaluated. The US parameters were divided into airway and nonairway parameters. A random-effects meta-analysis was planned, wherever applicable. RESULTS: Of the initial 3865 screened articles, 21 studies (7 airway and 14 nonairway) evaluating 3339 patients were included. Majority of studies were conducted in the general population (49%), respirology (23%), and sleep clinics (12%). No study evaluated the use of US for OSA in perioperative setting. Majority of included studies had low risk of bias for reference standard and flow and timing. Airway US parameters having moderate–good correlation with moderate–severe OSA were distance between lingual arteries (DLAs > 30 mm; sensitivity, 0.67; specificity, 0.59; 1 study/66 patients); mean resting tongue thickness (>60 mm; sensitivity, 0.85; specificity, 0.59; 1 study/66 patients); tongue base thickness during Muller maneuver (MM; sensitivity, 0.59; specificity, 0.78; 1 study/66 patients); and a combination of neck circumference and retropalatal (RP) diameter shortening during MM (sensitivity, 1.0; specificity, 0.65; 1 study/104 patients). Nonairway US parameters having a low–moderate correlation with moderate–severe OSA were carotid intimal thickness (pooled correlation coefficient, 0.444; 95% confidence interval [CI], 0.320–0.553; P value = .000, 8 studies/727 patients) and plaque presence (sensitivity, 0.24–0.75; specificity, 0.13–1.0; 4 studies/1183 patients). CONCLUSIONS: We found that a number of airway and nonairway parameters were identified with moderate to good correlation with OSA diagnosis in the general population. In future studies, it remains to be seen whether PoCUS screening for a combination of these parameters can address the pitfalls of OSA screening questionnaires.

Overview

Integrity signals

Registry

Crossref · 10.1213/ane.0000000000004350

Cites

87 of 87 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 87 references

Research works printed but not linked: 1

  1. Apaydin, 2013, Carotid intima-media thickness increase in sleep disorders., Neuroradiology, 55, S115

Cited by

See all 33

Metadata

Authors
Singh, M., Tuteja, A., Wong, D. T., Goel, A., Trivedi, A., Tomlinson, G., & Chan, V.
Affiliations
  • University Health Network (CA)
  • McMaster University (CA)
  • Mount Sinai Hospital (CA)
Corresponding author
  • Singh, Mandeep
  • Tuteja, Arvind
  • Wong, David T.
  • Goel, Akash
  • Chan, Vincent
Venue
Anesthesia & Analgesia
Published
2019-12
Volume
129
Issue
6
Pages
1673-1691
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2970394452
Cited by
33
References
86
Citations by year
2026: 2 · 2025: 6 · 2024: 6 · 2023: 4 · 2022: 6 · 2021: 6 · 2020: 1 · 2019: 2
FWCI
0.44
Type
journal article
Language
en
Open access
Locations
  • Anesthesia & Analgesia (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
Keywords
obstructive sleep apnea, point-of-care ultrasound, OSA screening, airway ultrasound, perioperative diagnosis, diagnostic accuracy, tongue thickness, Müller maneuver, neck circumference, airway assessment, non-invasive diagnosis, screening questionnaire, sleep-disordered breathing severity, risk of bias assessment, risk of overdiagnosis
MeSH terms
Humans, Mass Screening, Postoperative Complications, Polysomnography, Ultrasonography, Interventional, Point-of-Care Systems, Perioperative Care, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Point-of-Care Ultrasound for Obstructive Sleep Apnea Screening: Are We There Yet? A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1213/ane.0000000000004350
The paper
Singh, M., Tuteja, A., Wong, D. T., Goel, A., Trivedi, A., Tomlinson, G., & Chan, V. (2019). Point-of-Care Ultrasound for Obstructive Sleep Apnea Screening: Are We There Yet? A Systematic Review and Meta-analysis. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000004350

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.