Choice of Formula and Accuracy of Fetal Weight Estimation in Small‐for‐Gestational‐Age Fetuses
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Objectives: The purpose of this study was to identify the most accurate sonographic models for fetal weight estimation in specific subgroups of small‐for‐gestational‐age (SGA) fetuses. Methods: We conducted a retrospective study of women who delivered an SGA neonate and underwent a sonographic estimation of fetal weight within 7 days of delivery in a single tertiary center (n = 370). The accuracy of fetal weight estimation was compared for 33 sonographic models (27 nontargeted and 6 targeted SGA– or low‐birth‐weight–specific models) in specific subgroups of SGA fetuses: early versus late SGA, asymmetric versus symmetric, and presence of Doppler abnormalities. Results: A wide variation in the accuracy of the different models was found (systematic error, −12.5% to 15.1%; random error, 7.8% to 15.5%). Most nontargeted models tended to systematically overestimate the weight of SGA fetuses. The best performing model in the overall SGA group was the targeted model of Scott et al (J Ultrasound Med 1996; 15:669–672; systematic error ± random error, −2.8% ± 8.3%). However, the optimal models varied for different subgroups of SGA fetuses, and in most cases the targeted models were the most accurate. An approach that used the optimal model for each subgroup of SGA fetuses compared with the uniform use of the model of Scott et al for all SGA fetuses was associated with a lower systematic error (−0.38% versus −2.8%; P < .001) and a higher proportion of weight estimations within 5%, 10%, and 15% of birth weight (48.4% versus 40.8%; P= .038; 78.6% versus 71.4%; P= .022; 95.1% versus 89.2%; P = .003, respectively). Conclusions: Sonographic models in current use for fetal weight estimation in SGA fetuses have significant errors, and their performance varies for specific subgroups of SGA fetuses. An approach that uses subgroup‐specific models may improve the accuracy of weight estimation among SGA fetuses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682
In utero analysis of fetal growth: a sonographic weight standard
Hadlock, F. P., Harrist, R. B., & Martinez-Poyer, J. (1991) · Radiology · doi:10.1148/radiology.181.1.1887021 · Cited by 1,281
A systematic review of the ultrasound estimation of fetal weight
Dudley, N. J. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1751 · Cited by 537
The estimation of fetal weight by computer-assisted analysis
Warsof, S. L., Gohari, P., Berkowitz, R. L., & Hobbins, J. C. (1977) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(77)90058-8 · Cited by 355
Savchev, S., Figueras, F., Sanz-Cortes, M., Cruz-Lemini, M., Triunfo, S., Botet, F., & Gratacos, E. (2014) · Fetal Diagnosis and Therapy · doi:10.1159/000355525 · Cited by 182
Diagnosis of IUGR: traditional biometry
Platz, E., & Newman, R. (2008) · Seminars in Perinatology · doi:10.1053/j.semperi.2008.02.002 · Cited by 94
Cited by
Melamed, N., Baschat, A., Yinon, Y., Athanasiadis, A., Mecacci, F., Figueras, F., Berghella, V., Nazareth, A., Tahlak, M., McIntyre, H. D., et al. (2021) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.13522 · Cited by 570
Self-citationHammami, A., Mazer Zumaeta, A., Syngelaki, A., Akolekar, R., & Nicolaides, K. H. (2018) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.19066 · Cited by 170
“in all pregnancies but also in those with only small or only big babies.(50-57)”
BackgroundFetal growth velocity and body proportion in the assessment of growth
Hiersch, L., & Melamed, N. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.014 · Cited by 100
Self-citationMonier, I., Ego, A., Benachi, A., Ancel, P.-Y., Goffinet, F., & Zeitlin, J. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.08.012 · Cited by 32
Li, R., Song, F., Zhou, Q., Wu, W., Cao, Y., Zhang, G., Qian, Z., & Wang, L. (2025) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.29399 · Cited by 10
Metadata
- Authors
- Melamed, N., Ryan, G., Windrim, R., Toi, A., & Kingdom, J.
- Venue
- Journal of Ultrasound in Medicine
- Publisher
- Wiley
- Published
- 2016-01
- Volume
- 35
- Issue
- 1
- Pages
- 71-82
- ISSN
- 0278-4297 (ISSN-L)
- 1550-9613
- OpenAlex
- W2249053861
- Cited by
- 28
- References
- 6
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Choice of Formula and Accuracy of Fetal Weight Estimation in Small‐for‐Gestational‐Age Fetuses. https://app.cochat.ai/papers/10.7863/ultra.15.02058
- The paper
- Melamed, N., Ryan, G., Windrim, R., Toi, A., & Kingdom, J. (2016). Choice of Formula and Accuracy of Fetal Weight Estimation in Small‐for‐Gestational‐Age Fetuses. Journal of Ultrasound in Medicine. https://doi.org/10.7863/ultra.15.02058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.