CoChat

Detection and Molecular Identification of Persistent Water Vessel Colonizing Bacteria in a Table Water Factory in Nigeria

Open access
Nwaiwu, O, Nwachukwu, M · 2016 · British Microbiology Research Journal

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index; none of the 31 sources its claims cite is checked for support yet.

Abstract

Aims: To establish organisms persistent in a table water production facility and to determine the points they entered in order to eliminate any risk of having pathogens in a water production system.Study Design: Analytic observational studiesPlace and Duration of Study: Bottling facility in Nigeria and University of Nottingham, United Kingdom. Study was between August 2011 and Sept 2013.Methodology: Sample control points were subjected to counts of bacteria, yeasts, and mold using membrane filtration to trace the source of increased bacteria counts in a table water production factory. Organisms were identified by 16S rRNA sequencing and biofilm formation was assessed with micro titer dish biofilm formation analysis.Results: Total bacteria and Pseudomonas Spp. count were highest in the carbon filter and 5% (v/v) chlorine used for disinfection was found to be effective against planktonic cells of 18 hour cultures of Pseudomonas Spp. isolated from the carbon filter tank. No yeasts and mold were detected and after a sand blasting exercise to clean affected tanks, total bacteria counts on tryptone glucose extract medium decreased to less than factory allowable limits of 25 cfu per 100 ml of water with no further growth of Pseudomonas Spp. on centrimide medium. Other bacteria that emerged after the sand blasting exercise were regarded as persistent but had less biofilm forming ability (p=.02) when compared with Pseudomonas aeruginosa PAO1. The persistent bacteria identified after sequencing were Aeromonas hydrophila and Serratia proteamaculans.Conclusion: Apart from Pseudomonas Spp., other bacteria can persist in the water tanks of a water bottling facility and routine checks may fail to detect an underlying problem until it becomes obvious. Prompt corrective action ensures that public safety is not compromised. This was the first time Aeromonas hydrophila and Serratia proteamaculans were identified from the water tanks in the bottling facility.

Overview

CoChat Summary

TL;DR

A table water factory in southeastern Nigeria investigated persistent bacteria at critical control points and identified carbon-filter colonization as the contamination source. After sandblasting, the persistent organisms were molecularly identified as *Serratia proteamaculans* and *Aeromonas hydrophila*, with *Pseudomonas aeruginosa* PAO1 showing significantly greater biofilm formation than the isolates.

Key findings

  • Initial monitoring found growth only on total bacteria (TGE) and *Pseudomonas* (CT) media; no coliforms/enterobacteria, yeasts, or moulds were detected, and no growth occurred from the sand filter or finished bottled water throughout the study.
  • Bacteria counts were highest in the carbon and polishing filters and exceeded the factory limit of 25 colonies per 100 ml, while deep well, raw water, reaction tank, and filler machine counts were within allowable limits; the carbon filter was identified as the source because water entering it from the sand filter had zero growth.
  • Increasing clean-in-place chlorine from 40 ppm to 80 ppm reduced counts initially, but counts rose again a week later; after sandblasting the carbon filter and servicing the polishing filter, only TGE growth remained, with counts <6 cfu per 100 ml and no CT growth a week later.
  • Molecular identification after sandblasting found two yellowish colonies as *Serratia proteamaculans* and one brownish colony as *Aeromonas hydrophila* (EMBL accession numbers HG328350–HG328352); biofilm assays showed *P. aeruginosa* PAO1 formed significantly more biofilm than the isolates (p=.02), and chlorine at 5–30% w/v inhibited planktonic isolates while controls grew too numerous to count.

Methods

  • Case study in a table water production factory in southeastern Nigeria; 100 ml water samples were collected from the deep well, raw water tank, sand filter, reaction and carbon filter tanks, polishing filter, filler machine, and finished bottled water, and analyzed within 1 h.
  • Membrane filtration used nutrient pads: TGE for total bacteria, TTTC for coliforms/enterobacteria, CT for *Pseudomonas* and other non-faecal pathogenic bacteria, and SP for yeasts/moulds; incubations were 37°C for 24 h for bacteria, 42°C for 48 h for CT, and 25°C for 5 days for yeasts/moulds, with counts expressed as CFU per 100 ml and three replicates.
  • Chlorine efficacy was tested at 5, 10, 15, 20, and 30% w/v against isolates with a no-chlorine control; molecular identification used PCR of the V3 region of 16S rDNA (~203 bp), sequencing, BLAST, and EMBL/ENA deposition; biofilm formation was assessed by microtiter crystal violet assay against *P. aeruginosa* PAO1, with ANOVA at p=.05 using Microsoft Excel.

Limitations

  • Not stated in the paper; the paper has no explicit limitations section.
  • Evident from the text: the study is a single-factory case report in southeastern Nigeria, so findings may not be broadly generalizable to other water production facilities.
  • Evident from the text: species identification relied on a partial 16S rDNA V3 region (~203 bp) and closest-match BLAST rather than whole-genome or additional marker analysis, and no finished product contamination occurred, so public health risk is inferred from system colonization.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.9734/bmrj/2016/24378

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 0 Not valid · 32 Not checked · 44 Own results and interpretations

23 more claims

Create a free account to see all 76 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 23
  • Probably not a substantial claim. 33

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 44 references

Research works printed but not linked: 4

  1. Microbiological investigation of an industrial ultra-pure supply water plant using cultivation-based and cultivationindependent methods. V Bohus, E M Tóth, A J Székely, J Makk, K Baranyi, G Patek, J Schunk, K Márialigeti, 10.1016/j.watres.2010.07.006Water Res. 44202010 · doi:10.1016/j.watres.2010.07.006water
  2. Persistence of Pseudomonas aeruginosa in drinkingwater biofilms on elastomeric material. D Bressler, M Balzer, A Dannehl, H-C Flemming, J Wingender, 10.2166/ws.2009.026Water Sci Technol. 912009 · doi:10.2166/ws.2009.026water
  3. The genus Serratia. F Grimont, Pad Grimont, 10.1007/0-387-30746-x_11Prokaryotes. 62006 · doi:10.1007/0-387-30746-x_11prokaryotes
  4. Kinetics of biofilm formation and desiccation survival of Listeria monocytogenes in single and dual species biofilms with Pseudomonas fluorescens, Serratia proteamaculans or Shewanella baltica on food-grade stainless steel surfaces. Daneshvar Alavi, H E , Truelstrup Hansen, L , 10.1080/08927014.2013.835805Biofouling. 29102013 · doi:10.1080/08927014.2013.835805biofouling

Cited by

See all 8

Metadata

Authors
Nwaiwu, O., & Nwachukwu, M.
Affiliations
  • University of Nottingham (GB)
  • Imo State University (NG)
Venue
British Microbiology Research Journal
Published
2016-01-10
Volume
13
Issue
5
Pages
1-12
ISSN
2231-0886 (ISSN-L)
OpenAlex
W2334650275
Cited by
6
References
44
Citations by year
2026: 1 · 2020: 2 · 2019: 1 · 2017: 2
FWCI
0.52
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • British Microbiology Research Journal (publishedVersion)
  • Microbiology Research Journal International (publishedVersion, cc-by)
  • HAL (submittedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Bacterial biofilms and quorum sensing
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Water Treatment and Disinfection
  • Physical Sciences › Environmental Science › Water Science and Technology › Fecal contamination and water quality
Keywords
drinking water contamination, bacterial detection, molecular identification, waterborne pathogens

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.