A review of common errors in the indirect measurement of blood pressure. Sphygmomanometry
The DOI matches its OpenAlex record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
There are three sources of error in the indirect measurement of blood pressure: (1) observer bias, (2) faulty equipment, and (3) failure to standardize the techniques of measurement. This article examines each area extensively, discusses the cumulative effect of these errors on the accuracy of indirect blood pressure measurement, and reviews the recommendations for proper indirect measurement of blood pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Observer bias in blood pressure studies
Bruce, N. G., Shaper, A. G., Walker, M., & Wannamethee, G. (1988) · Journal of Hypertension · doi:10.1097/00004872-198805000-00006 · Cited by 144
Korotkoff Sounds: An Experimental Critique
MCCUTCHEON, E. P., RUSHMER, R. F., Jacobson, O., & Sandier, H. (1967) · Circulation Research · doi:10.1161/01.res.20.2.149 · Cited by 95
Cited by
An Integrated Approach to Communication Theory and Research
(2014) · Routledge eBooks · doi:10.4324/9780203887011 · Cited by 981
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357
Measurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
Novel methods of testing and calibration of oscillometric blood pressure monitors
Celler, B. G., Argha, A., Le, P. N., & Ambikairajah, E. (2018) · PLOS ONE · doi:10.1371/journal.pone.0201123 · Cited by 28
G. Celler, B., Butlin, M., Argha, A., Tan, I., Yong, A., & Avolio, A. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3079578 · Cited by 24
Metadata
- Authors
- Bailey, R. H.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association
- Published
- 1993-12-27
- Volume
- 153
- Issue
- 24
- Pages
- 2741-2748
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W4232029603
- Cited by
- 124
- References
- 2
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A review of common errors in the indirect measurement of blood pressure. Sphygmomanometry. https://app.cochat.ai/papers/10.1001/archinte.153.24.2741
- The paper
- Bailey, R. H. (1993). A review of common errors in the indirect measurement of blood pressure. Sphygmomanometry. Archives of Internal Medicine. https://doi.org/10.1001/archinte.153.24.2741
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.