Cited by 24Cardiovascular Health and Disease PreventionBlood Pressure and Hypertension StudiesNon-Invasive Vital Sign Monitoring

Are Korotkoff Sounds Reliable Markers for Accurate Estimation of Systolic and Diastolic Pressure Using Brachial Cuff Sphygmomanometry?

G. Celler, Branko, Butlin, Mark, Argha, Ahmadreza, Tan, Isabella, Yong, Andy, Avolio, Alberto·2021·IEEE Transactions on Biomedical Engineering

Abstract

It is well known that non-invasive blood pressure measurements significantly underestimate true systolic blood pressure (SBP), and overestimate diastolic blood pressure (DBP). The aetiology for these errors has not yet been fully established. This study aimed to investigate the accuracy of Korotkoff sounds for detection of SBP and DBP points as used in brachial cuff sphygmomanometry. Brachial cuff pressure and Korotkoff sounds were obtained in 11 patients (6 males: 69.0 ± 6.2 years, 5 females: 71.8 ± 5.5 years) undergoing diagnostic coronary angiography. K2 Korotkoff sounds were obtained by high-pass filtering (>20 Hz) the microphone-recorded signal to eliminate low frequency components. Analysis of the timing of K2 Korotkoff sounds relative to cuff pressure and intra-arterial pressure shows that the onset of K2 Korotkoff sounds reliably detect the start of blood flow under the brachial cuff and their termination, marks the cuff pressure closely coincident with DBP. We have made the critical observation that blood flow under the cuff does not begin when cuff pressure falls just below SBP as is conventionally assumed, and that the delay in the opening of the artery following occlusion, and the consequent delay in the generation of K2 Korotkoff sounds, may lead to significant errors in the determination of SBP of up to 24 mmHg. Our data suggest a potential role of arterial stiffness as a major component of the errors recorded, with underestimation of SBP much more significant for subjects with stiff arteries than for subjects with more compliant arteries.

Integrity signals

Registry

Crossref · 10.1109/tbme.2021.3079578

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The variability in error for systolic and diastolic BP plausibly interacts with arterial stiffness, resulting in Korotkoff sounds I and V being separate events from the exact movement of cuff pressure past systolic and diastolic BP.

    “The variability in error for systolic and diastolic BP plausibly has interaction with arterial stiffness, resulting in Korotkoff sounds I and V being separate events from the exact movement of the cuff pressure past the systolic and diastolic BP [43].”

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. 10.1001/archinte.1993.00410240045005 · DOI

Cited by

Sorted by citations

Authors
G. Celler, B., Butlin, M., Argha, A., Tan, I., Yong, A., & Avolio, A.
Affiliations
  • Macquarie University (AU)
  • UNSW Sydney (AU)
Venue
IEEE Transactions on Biomedical Engineering
Published
2021-12
Volume
68
Issue
12
Pages
3593-3601
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W3161802816
Cited by
24
References
47
Citations by year
2026: 3 · 2025: 2 · 2024: 9 · 2023: 5 · 2022: 3 · 2021: 2
FWCI
3.21
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
Korotkoff sounds, systolic blood pressure estimation, diastolic blood pressure estimation, blood pressure measurement error, arterial stiffness, cuff pressure, intra-arterial blood pressure, coronary angiography
MeSH terms
Blood Pressure, Blood Pressure Determination, Brachial Artery, Female, Humans, Male, Systole

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review