CoChat

Novel methods of testing and calibration of oscillometric blood pressure monitors

Open access
Celler, Branko G., Argha, Ahmadreza, Le, Phu Ngoc, Ambikairajah, Eliathamby · 2018 · PLOS ONE

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

We present a robust method for testing and calibrating the performance of oscillometric non-invasive blood pressure (NIBP) monitors, using an industry standard NIBP simulator to determine the characteristic ratios used, and to explore differences between different devices. Assuming that classical auscultatory sphygmomanometry provides the best approximation to intra-arterial pressure, the results obtained from oscillometric measurements for a range of characteristic ratios are compared against a modified auscultatory method to determine an optimum characteristic ratio, Rs for systolic blood pressure (SBP), which was found to be 0.565. We demonstrate that whilst three Chinese manufactured NIBP monitors we tested used the conventional maximum amplitude algorithm (MAA) with characteristic ratios Rs = 0.4624±0.0303 (Mean±SD) and Rd = 0.6275±0.0222, another three devices manufactured in Germany and Japan either do not implement this standard protocol or used different characteristic ratios. Using a reference database of 304 records from 102 patients, containing both the Korotkoff sounds and the oscillometric waveforms, we showed that none of the devices tested used the optimal value of 0.565 for the characteristic ratio Rs, and as a result, three of the devices tested would underestimate systolic pressure by an average of 4.8mmHg, and three would overestimate the systolic pressure by an average of 6.2 mmHg.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0201123

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Schematic diagram of testing configuration for NIBP oscillometric monitors using the Fluke BP NIBP Analyser.
Fig 1 Schematic diagram of testing configuration for NIBP oscillometric monitors using the Fluke BP NIBP Analyser.CC BY · PubMed Central
Fig 2 Development of Oscillometric Waveform Envelope (OMWE) and determination of characteristic points Rs, and Rd with SBP and DBP points set at 120/80 mm Hg.
Fig 2 Development of Oscillometric Waveform Envelope (OMWE) and determination of characteristic points Rs, and Rd with SBP and DBP points set at 120/80 mm Hg.CC BY · PubMed Central
Fig 3 Sample blood pressure record (Panels A-D) from reference database and derived OMWE (Panel E). The vertical dashed lines points to the SBP at which the first Korotkoff sound appears.
Fig 3 Sample blood pressure record (Panels A-D) from reference database and derived OMWE (Panel E). The vertical dashed lines points to the SBP at which the first Korotkoff sound appears.CC BY · PubMed Central
Fig 4 Bland-Altman plots comparing oscillometric estimates of systolic pressure using the characteristic ratio of Rs = 0.565, against reference auscultatory systolic pressure.
Fig 4 Bland-Altman plots comparing oscillometric estimates of systolic pressure using the characteristic ratio of Rs = 0.565, against reference auscultatory systolic pressure.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 31

Metadata

Authors
Celler, B. G., Argha, A., Le, P. N., & Ambikairajah, E.
Affiliations
UNSW Sydney (AU)
Corresponding author
Celler, Branko G.
Venue
PLOS ONE
Published
2018-08-06
Volume
13
Issue
8
Pages
e0201123
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2887864701
Cited by
28
References
31
Citations by year
2025: 1 · 2024: 4 · 2023: 7 · 2022: 4 · 2021: 2 · 2020: 7 · 2019: 3
FWCI
1.20
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • UNSWorks (University of New South Wales, Sydney, Australia) (submittedVersion, cc-by-nc-nd)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
Australian Research Council (LP160101202)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
oscillometric blood pressure measurement, characteristic ratio, systolic blood pressure estimation, Korotkoff sounds, intra-arterial blood pressure, device performance comparison
MeSH terms
Adult, Aged, Aged, 80 and over, Algorithms, Blood Pressure, Blood Pressure Determination, Calibration, Female, Humans, Male, Middle Aged, Oscillometry, Blood Pressure Monitors, Databases, Factual, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Novel methods of testing and calibration of oscillometric blood pressure monitors. https://app.cochat.ai/papers/10.1371/journal.pone.0201123
The paper
Celler, B. G., Argha, A., Le, P. N., & Ambikairajah, E. (2018). Novel methods of testing and calibration of oscillometric blood pressure monitors. PLOS ONE. https://doi.org/10.1371/journal.pone.0201123

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.