The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
The Aneurysm Detection and Management Study Screening Program: Validation Cohort and Final Results
Open accessAbstract
BACKGROUND: We previously reported the prevalence and associations of abdominal aortic aneurysm (AAA) in 73451 veterans aged 50 to 79 years who underwent ultrasound screening. OBJECTIVE: To understand the prevalence of and principal positive and negative risk factors for AAA, and to assess reproducibility of our previous findings. METHODS: In the new cohort of veterans undergoing screening, 52 745 subjects aged 50 to 79 without history of AAA underwent successful ultrasound screening for AAA, after completing a questionnaire on demographics and potential risk factors. RESULTS: We detected AAA of 4.0 cm or larger in 613 participants (1.2%; compared with 1.4% in the earlier cohort). The direction and magnitude of the important associations reported in the first cohort were confirmed. Respective odds ratios for the major associations with AAA for the second and for the combined cohorts were as follows: 1.81 and 1.71 for age (per 7 years), 0.12 and 0. 18 for female sex, 0.59 and 0.53 for black race, 1.94 and 1.94 for family history of AAA, 4.45 and 5.07 for smoking, 0.50 and 0.52 for diabetes, and 1.60 and 1.66 for atherosclerotic diseases. The excess prevalence associated with smoking accounted for 75% of all AAAs of 4.0 cm or larger in the total population of 126 196. Associations for AAA of 3.0 to 3.9 cm were similar but tended to be somewhat weaker. CONCLUSIONS: Our findings confirm our previous cohort findings. Age, smoking, family history of AAA, and atherosclerotic diseases remained the principal positive associations with AAA, and female sex, diabetes, and black race remained the principal negative associations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Case-Control Studies: Design, Conduct, Analysis.
Youkeles, L., & Schlesselman, J. J. (1983) · Journal of the American Statistical Association · doi:10.2307/2288156 · Cited by 2,346
Assessing the Generalizability of Prognostic Information
Justice, A. C., Covinsky, K. E., & Berlin, J. A. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00016 · Cited by 1,160
Prevalence and Associations of Abdominal Aortic Aneurysm Detected through Screening
Lederle, F. A., Johnson, G. R., Wilson, S. E., Chute, E. P., Littooy, F. N., Bandyk, D., Krupski, W. C., Barone, G. W., Acher, C. W., & Ballard, D. J. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-6-199703150-00004 · Cited by 915
Self-citationSilverberg, E., Boring, C. C., & Squires, T. S. (1990) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.40.1.9 · Cited by 816
Diameter and compliance in the male human abdominal aorta: Influence of age and aortic aneurysm
Länne, T., Sonesson, B., Bergqvist, D., Bengtsson, H., & Gustafsson, D. (1992) · European Journal of Vascular Surgery · doi:10.1016/s0950-821x(05)80237-3 · Cited by 197
Unfavorable effects of passive smoking on aortic function in men
Stefanadis, C., Vlachopoulos, C., Tsiamis, E., Diamantopoulos, L., Toutouzas, K., Giatrakos, N., Vaina, S., Tsekoura, D., & Toutouzas, P. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-128-6-199803150-00002 · Cited by 132
Ultrasonographic screening for abdominal aortic aneurysm in an urban community
Smith, F. C. T., Grimshaw, G. M., Paterson, I., et al. (1993) · British journal of surgery · doi:10.1002/bjs.1800801117 · Cited by 120
Mechanical properties of the aneurysmal aorta
MacSweeney, S. T. R., Young, G., Greenhalgh, R. M., & Powell, J. T. (1992) · British journal of surgery · doi:10.1002/bjs.1800791211 · Cited by 118
Design of the abdominal aortic Aneurysm Detection and Management Study
Lederle, F. A., Wilson, S. E., Johnson, G. R., Littooy, F. N., Acher, C. W., Messina, L. M., Reinke, D. B., & Ballard, D. (1994) · Journal of Vascular Surgery · doi:10.1016/0741-5214(94)90019-1 · Cited by 98
Self-citationDiverse Roles of Macrophage Matrix Metalloproteinases in Tissue Destruction and Tumor Growth
Shapiro, S. D. (1999) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1615921 · Cited by 94
Cited by
Heart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
Heart Disease and Stroke Statistics—2022 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Alonso, A., Beaton, A. Z., Bittencourt, M. S., Boehme, A. K., Buxton, A. E., Carson, A. P., Commodore-Mensah, Y., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001052 · Cited by 5,987
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.174526 · Cited by 3,708
Martin, S. S., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Barone Gibbs, B., Beaton, A. Z., Boehme, A. K., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001209 · Cited by 2,800
Chaikof, E. L., Dalman, R. L., Eskandari, M. K., Jackson, B. M., Lee, W. A., Mansour, M. A., Mastracci, T. M., Mell, M., Murad, M. H., Nguyen, L. L., et al. (2018) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2017.10.044 · Cited by 2,751
Metadata
- Authors
- Lederle, F. A.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2000-05-22
- Volume
- 160
- Issue
- 10
- Pages
- 1425
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2100392330
- Cited by
- 722
- References
- 13
- FWCI
- 10.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Aneurysm Detection and Management Study Screening Program: Validation Cohort and Final Results. https://app.cochat.ai/papers/10.1001/archinte.160.10.1425
- The paper
- Lederle, F. A. (2000). The Aneurysm Detection and Management Study Screening Program: Validation Cohort and Final Results. Archives of Internal Medicine. https://doi.org/10.1001/archinte.160.10.1425
Data sources