The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Effects of Computerized Physician Order Entry on Prescribing Practices
Abstract
BACKGROUND: Computerized order entry systems have the potential to prevent errors, to improve quality of care, and to reduce costs by providing feedback and suggestions to the physician as each order is entered. This study assesses the impact of an inpatient computerized physician order entry system on prescribing practices. METHODS: A time series analysis was performed at an urban academic medical center at which all adult inpatient orders are entered through a computerized system. When physicians enter drug orders, the computer displays drug use guidelines, offers relevant alternatives, and suggests appropriate doses and frequencies. RESULT: For medication selection, use of a computerized guideline resulted in a change in use of the recommended drug (nizatidine) from 15.6% of all histamine(2)-blocker orders to 81.3% (P<.001). Implementation of dose selection menus resulted in a decrease in the SD of drug doses by 11% (P<.001). The proportion of doses that exceeded the recommended maximum decreased from 2.1% before order entry to 0.6% afterward (P<.001). Display of a recommended frequency for ondansetron hydrochloride administration resulted in an increase in the use of the approved frequency from 6% of all ondansetron orders to 75% (P<.001). The use of subcutaneous heparin sodium to prevent thrombosis in patients at bed rest increased from 24% to 47% when the computer suggested this option (P<.001). All these changes persisted at 1- and 2-year follow-up analyses. CONCLUSION: Computerized physician order entry is a powerful and effective tool for improving physician prescribing practices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Incidence of Adverse Drug Events and Potential Adverse Drug Events: Implications for Prevention
Bates, D. W. (1995) · JAMA · doi:10.1001/jama.1995.03530010043033 · Cited by 2,127
Self-citationBates, D. W. (1998) · JAMA · doi:10.1001/jama.280.15.1311 · Cited by 2,107
Self-citationJohnston, M. E., Langton, K. B., Haynes, R. B., & Mathieu, A. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-2-199401150-00007 · Cited by 714
Physician inpatient order writing on microcomputer workstations. Effects on resource utilization
Tierney, W. M. (1993) · JAMA · doi:10.1001/jama.269.3.379 · Cited by 557
A Randomized Trial of "Corollary Orders" to Prevent Errors of Omission
Overhage, J. M., Tierney, W. M., Zhou, X.-H., & McDonald, C. J. (1997) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1997.0040364 · Cited by 375
Lobach, D. F., & Hammond, W. E. (1997) · The American Journal of Medicine · doi:10.1016/s0002-9343(96)00382-8 · Cited by 303
McLaughlin, T. J. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.156.7.799 · Cited by 302
Massaro, T. A. (1993) · Academic Medicine · doi:10.1097/00001888-199301000-00003 · Cited by 287
Implementation of Physician Order Entry: User Satisfaction and Self-Reported usage Patterns
Lee, F., Teich, J. M., Spurr, C. D., & Bates, D. W. (1996) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1996.96342648 · Cited by 260
Self-citationComputerized Prescribing: Building the Electronic Infrastructure for Better Medication Usage
Schiff, G. D., & Rucker, T. D. (1998) · JAMA · doi:10.1001/jama.279.13.1024 · Cited by 247
Litzelman, D. K., Dittus, R. S., Miller, M. E., & Tierney, W. M. (1993) · Journal of General Internal Medicine · doi:10.1007/bf02600144 · Cited by 236
Psychoactive medication use in intermediate-care facility residents
Beers, M. H. (1988) · JAMA · doi:10.1001/jama.260.20.3016 · Cited by 229
Reducing Vancomycin Use Utilizing a Computer Guideline: Results of a Randomized Controlled Trial
Shojania, K. G., Yokoe, D., Platt, R., Fiskio, J., Ma'luf, N., & Bates, D. W. (1998) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1998.0050554 · Cited by 211
Self-citationComputerized physician order entry and quality of care
Bates, D. W., Kuperman, G. J., & Teich, J. M. (1994) · Quality Management in Health Care · doi:10.1097/00019514-199402040-00005 · Cited by 116
Self-citationEfficacy and Cost-Containment in Hospital Pharmacotherapy: State of the Art and Future Directions
Soumerai, S. B., & Avorn, J. (1984) · The Milbank Memorial Fund Quarterly Health and Society · doi:10.2307/3349860 · Cited by 103
Increased Incidence of Levodopa Therapy Following Metoclopramide Use
Avorn, J., Gurwitz, J. H., Bohn, R. L., Mogun, H., Monane, M., & Walker, A. (1995) · JAMA · doi:10.1001/jama.1995.03530220046031 · Cited by 67
Computerizing guidelines: factors for success.
Tierney, W. M., Overhage, J. M., & McDonald, C. J. (1996) · PubMed · Cited by 63
Teich, J. M., Hurley, J. F., Beckley, R. F., & Aranow, M. (1992) · PubMed Central · Cited by 43
Self-citationResponse to a trial of physician-based inpatient order entry.
Teich, J. M., Spurr, C. D., Flammini, S., Schmiz, J. L., Beckley, R. F., Hurley, J. F., Aranow, M., & GLASER, J. P. (1993) · PubMed Central · Cited by 30
Self-citationAn information system to improve the safety and efficiency of chemotherapy ordering.
Teich, J. M., Schmiz, J. L., O'Connell, E. M., Fanikos, J. R., Marks, P. W., & Shulman, L. N. (1996) · Europe PMC (PubMed Central) · Cited by 16
Self-citationAn institution-based process to ensure clinical software quality.
Abookire, S. A., Teich, J. M., & Bates, D. W. (1999) · PubMed · Cited by 6
Self-citation
Cited by
Chaudhry, B., Wang, J., Wu, S., Maglione, M., Mojica, W., Roth, E., Morton, S. C., & Shekelle, P. G. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-10-200605160-00125 · Cited by 3,159
Role of Computerized Physician Order Entry Systems in Facilitating Medication Errors
Koppel, R. (2005) · JAMA · doi:10.1001/jama.293.10.1197 · Cited by 2,126
Ash, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1471 · Cited by 1,789
Improving Safety with Information Technology
Bates, D. W., & Gawande, A. A. (2003) · New England Journal of Medicine · doi:10.1056/nejmsa020847 · Cited by 1,544
Self-citationBates, D. W., Kuperman, G. J., Wang, S., Gandhi, T., Kittler, A., Volk, L., Spurr, C., Khorasani, R., Tanasijevic, M., & Middleton, B. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1370 · Cited by 1,346
Self-citation
Metadata
- Authors
- Teich, J. M., Merchia, P. R., Schmiz, J. L., Kuperman, G. J., Spurr, C. D., & Bates, D. W.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2000-10-09
- Volume
- 160
- Issue
- 18
- Pages
- 2741
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2168465029
- Cited by
- 475
- References
- 21
- FWCI
- 75.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.