The DOI matches its Crossref record.
Suspected Pulmonary Embolism in Pregnancy: Clinical Presentation, Results of Lung Scanning, and Subsequent Maternal and Pediatric Outcomes
Abstract
BACKGROUND: Ventilation-perfusion (VQ) scanning is used when pulmonary embolism (PE) is suspected during pregnancy; however, the distribution of lung scan results and safety of VQ scanning have never been studied. OBJECTIVE: To study the distribution of lung scan results and safety of VQ scanning as well as the safety of withholding anticoagulation therapy following a normal or nondiagnostic scan in pregnant women. METHODS: The study group comprised 120 consecutive pregnant women who presented with suspected PE. Clinical data were collected, and the lung scans were reinterpreted by 2 independent experts. Subsequent pregnancy and pediatric outcomes were determined by direct patient follow-up. RESULTS: During the study period, 120 pregnant women (mean age, 32 years) underwent 121 VQ scans. Eight cases (6.6%) were already receiving treatment for venous thromboembolism prior to VQ scanning. In the remaining 113 scans, 83 (73.5%) were interpreted as normal, 28 (24.8%) as nondiagnostic, and 2 (1.8%) as high probability. In the 104 women who did not receive anticoagulation therapy following lung scanning (80 normal and 24 nondiagnostic), no venous thromboembolic events were reported (mean [range] length of follow-up, 20.6 [0.5-108] months). Examination of pediatric data from 110 live births (90.2%) (mean [range] age, 20.5 [0.5-100] months) revealed no increase in the rates of congenital and developmental anomalies. CONCLUSIONS: The prevalence of high-probability VQ scans in pregnant women with suspected PE and probable PE is very low. Withholding anticoagulation in pregnant women with normal or nondiagnostic VQ scans is probably safe. In addition, pediatric risks from VQ scans are low. Large prospective studies are needed to evaluate diagnostic strategies for pregnant women with suspected PE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz405 · Cited by 4,916
2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Torbicki, A., Perrier, A., Konstantinides, S., Agnelli, G., Galiè, N., Pruszczyk, P., Bengel, F., Brady, A. J. B., Ferreira, D., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn310 · Cited by 2,826
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01647-2019 · Cited by 1,619
Use of Antithrombotic Agents During Pregnancy
Bates, S. M., Greer, I. A., Hirsh, J., & Ginsberg, J. S. (2004) · Chest · doi:10.1378/chest.126.3_suppl.627s · Cited by 552
Self-citation
Metadata
- Authors
- Chan, W. S., Ray, J. G., Murray, S., Coady, G. E., Coates, G., & Ginsberg, J. S.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2002-05-27
- Volume
- 162
- Issue
- 10
- Pages
- 1170
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W1980621470
- Cited by
- 190
- References
- 0
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Suspected Pulmonary Embolism in Pregnancy: Clinical Presentation, Results of Lung Scanning, and Subsequent Maternal and Pediatric Outcomes. https://app.cochat.ai/papers/10.1001/archinte.162.10.1170
- The paper
- Chan, W. S., Ray, J. G., Murray, S., Coady, G. E., Coates, G., & Ginsberg, J. S. (2002). Suspected Pulmonary Embolism in Pregnancy: Clinical Presentation, Results of Lung Scanning, and Subsequent Maternal and Pediatric Outcomes. Archives of Internal Medicine. https://doi.org/10.1001/archinte.162.10.1170
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.