CoChat

Implantable Cardioverter Defibrillators and Quality of Life<subtitle>Results From the Defibrillators in Nonischemic Cardiomyopathy Treatment Evaluation Study</subtitle>

Passman, Rod · 2007 · Archives of Internal Medicine
Cited by 134

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The Defibrillators in Nonischemic Cardiomyopathy Treatment Evaluation study demonstrated that implantable cardioverter defibrillators (ICDs) significantly reduce the risk of sudden cardiac death in patients with nonischemic cardiomyopathy and an ejection fraction of 35% or less, with no statistically significant decrease in overall mortality. The impact of ICD placement and shock on health-related quality of life (HRQL) in this population is unknown. METHODS: The 12-Item Medical Outcomes Short-Form Health Survey and the Minnesota Living with Heart Failure Questionnaire were administered to 458 patients with nonischemic cardiomyopathy, an ejection fraction of 35% or less, and either nonsustained ventricular tachycardia or 10 or more premature ventricular depolarizations per hour at baseline, 1 month after randomization, and every 3 months thereafter throughout the trial. The subjects were randomized to an ICD or standard medical therapy. Outcomes were compared using hierarchical linear regression. RESULTS: Overall, there were no significant differences in HRQL throughout the trial between patients randomized to an ICD or standard medical therapy. However, in patients with 1 or more ICD shocks, HRQL declined 0.5 +/- 0.2 (mean +/- SD) points per shock on the emotional scale of the Minnesota Living with Heart Failure Questionnaire (P = .04) and 1.0 +/- 0.5 points per shock on the mental component score of the 12-Item Medical Outcomes Short-Form Health Survey (P = .04). CONCLUSIONS: Overall, HRQL was not affected by ICD implantation in patients in the Defibrillators in Nonischemic Cardiomyopathy Treatment Evaluation study. Implantable cardioverter defibrillator shock was associated with a reduction in some measures of HRQL, but the effects were unlikely to result in a clinically observable alteration until 5 or more shocks were experienced.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinte.167.20.2226

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 134

Metadata

Authors
Passman, R.
Venue
Archives of Internal Medicine
Published
2007-11-12
Volume
167
Issue
20
Pages
2226
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2048422567
Cited by
134
References
3
FWCI
5.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Implantable Cardioverter Defibrillators and Quality of Life<subtitle>Results From the Defibrillators in Nonischemic Cardiomyopathy Treatment Evaluation Study</subtitle>. https://app.cochat.ai/papers/10.1001/archinte.167.20.2226
The paper
Passman, R. (2007). Implantable Cardioverter Defibrillators and Quality of Life<subtitle>Results From the Defibrillators in Nonischemic Cardiomyopathy Treatment Evaluation Study</subtitle>. Archives of Internal Medicine. https://doi.org/10.1001/archinte.167.20.2226

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.