Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 551

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

One-Hour Rule-out and Rule-in of Acute Myocardial Infarction Using High-Sensitivity Cardiac Troponin T

Reichlin, Tobias, Schindler, Christian, Drexler, Beatrice, Twerenbold, Raphael, Reiter, Miriam, Zellweger, Christa, Moehring, Berit, Ziller, Ronny, Hoeller, Rebeca, Rubini Gimenez, Maria, Haaf, Philip, Potocki, Mihael, Wildi, Karin, Balmelli, Cathrin, Freese, Michael, Stelzig, Claudia, Freidank, Heike, Osswald, Stefan, Mueller, Christian·2012·Archives of Internal Medicine

Abstract

BACKGROUND: High-sensitivity cardiac troponin (hs-cTn) assays seem to improve the early diagnosis of acute myocardial infarction (AMI), but it is unknown how to best use them in clinical practice. Our objective was to develop and validate an algorithm for rapid rule-out and rule-in of AMI. METHODS: A prospective multicenter study enrolling 872 unselected patients with acute chest pain presenting to the emergency department. High-sensitivity cardiac troponin T (hs-cTnT) was measured in a blinded fashion at presentation and after 1 hour. The final diagnosis was adjudicated by 2 independent cardiologists. An hs-cTnT algorithm incorporating baseline values as well as absolute changes within the first hour was derived from 436 randomly selected patients and validated in the remaining 436 patients. The primary prognostic end point was death during 30 days of follow-up. RESULTS: Acute myocardial infarction was the final diagnosis in 17% of patients. After applying the hs-cTnT algorithm developed in the derivation cohort to the validation cohort, 259 patients (60%) could be classified as "rule-out," 76 patients (17%) as "rule-in," and 101 patients (23%) as in the "observational zone" within 1 hour. Overall, this resulted in a sensitivity and negative predictive value of 100% for rule-out, a specificity and positive predictive value of 97% and 84%, respectively, for rule-in, and a prevalence of AMI of 8% in the observational zone group. Cumulative 30-day survival was 99.8%, 98.6%, and 95.3% (P < .001) in patients classified as rule-out, observational zone, and rule-in, respectively. CONCLUSIONS: Using a simple algorithm incorporating hs-cTnT baseline values and absolute changes within the first hour allowed a safe rule-out as well as an accurate rule-in of AMI within 1 hour in 77% of unselected patients with acute chest pain. This novel strategy may obviate the need for prolonged monitoring and serial blood sampling in 3 of 4 patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinternmed.2012.3698

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 551

Metadata

Authors
Reichlin, T., Schindler, C., Drexler, B., Twerenbold, R., Reiter, M., Zellweger, C., Moehring, B., Ziller, R., Hoeller, R., Rubini Gimenez, M., Haaf, P., Potocki, M., Wildi, K., Balmelli, C., Freese, M., Stelzig, C., Freidank, H., Osswald, S., & Mueller, C.
Venue
Archives of Internal Medicine
Published
2012-09-10
Volume
172
Issue
16
Pages
1211
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2107955926
Cited by
551
References
34
FWCI
25.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: One-Hour Rule-out and Rule-in of Acute Myocardial Infarction Using High-Sensitivity Cardiac Troponin T. https://app.cochat.ai/papers/10.1001/archinternmed.2012.3698
The paper
Reichlin, T., Schindler, C., Drexler, B., Twerenbold, R., Reiter, M., Zellweger, C., Moehring, B., Ziller, R., Hoeller, R., Rubini Gimenez, M., Haaf, P., Potocki, M., Wildi, K., Balmelli, C., Freese, M., Stelzig, C., Freidank, H., Osswald, S., & Mueller, C. (2012). One-Hour Rule-out and Rule-in of Acute Myocardial Infarction Using High-Sensitivity Cardiac Troponin T. Archives of Internal Medicine. https://doi.org/10.1001/archinternmed.2012.3698

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.