The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Anterior Chamber Depth Measurement as a Screening Tool for Primary Angle-closure Glaucoma in an East Asian Population
Abstract
OBJECTIVE: To evaluate anterior chamber depth measurement as a method of screening for primary angle-closure glaucoma in an East Asian population. DESIGN: Two-phase, cross-sectional, community-based study. SETTING: Rural and urban locations in the Hovsgol and Omnogobi provinces, Mongolia. PARTICIPANTS: Nine hundred forty-two (94.2%) of 1000 individuals in Hovsgol(1995) and 775 (96.9%) of 1000 individuals in Omnogobi (1997) aged 40 years or older were examined. MAIN OUTCOME MEASURES: Anterior chamber depth was measured by optical pachymetry, slitlamp-mounted A-mode ultrasound, and handheld ultrasound. Gonioscopy was used to detect occludable angles, defined as one in which the trabecular meshwork was visible for less than 90 degrees of angle circumference. Primary open-angle glaucoma was diagnosed in subjects with an occludable angle and glaucomatous optic neuropathy with visual morbidity. The area under the curve in a receiver operating characteristic plot was used to compare test performance. RESULTS: Optical pachymetry outperformed the slitlamp-mounted ultrasound method of anterior chamber depth measurement (area under the curve, 0.93 and 0.90, respectively; z test, P = .001). Handheld ultrasound (area under the curve, 0.86) was inferior to optical measurement (z test, P = .001) but did not differ significantly from slitlamp ultrasound (z test, P = .06). The optical method gave sensitivity of 85% and specificity of 84% at a screening cutoff of less than 2.22 mm for detecting occludable angles. CONCLUSIONS: Measurement of axial anterior chamber depth can detect occludable angles in this Asian population and therefore may have a role in population screening for primary angle-closure glaucoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Foster, P. J. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.8.1105 · Cited by 628
Glaucoma in China: how big is the problem?
Foster, P. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.11.1277 · Cited by 598
Metadata
- Authors
- Devereux, J. G.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2000-02-01
- Volume
- 118
- Issue
- 2
- Pages
- 257
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2018434920
- Cited by
- 185
- References
- 1
- FWCI
- 5.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anterior Chamber Depth Measurement as a Screening Tool for Primary Angle-closure Glaucoma in an East Asian Population. https://app.cochat.ai/papers/10.1001/archopht.118.2.257
- The paper
- Devereux, J. G. (2000). Anterior Chamber Depth Measurement as a Screening Tool for Primary Angle-closure Glaucoma in an East Asian Population. Archives of Ophthalmology. https://doi.org/10.1001/archopht.118.2.257
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.