Anterior Chamber Depth Measurement as a Screening Tool for Primary Angle-closure Glaucoma in an East Asian Population
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate anterior chamber depth measurement as a method of screening for primary angle-closure glaucoma in an East Asian population. DESIGN: Two-phase, cross-sectional, community-based study. SETTING: Rural and urban locations in the Hovsgol and Omnogobi provinces, Mongolia. PARTICIPANTS: Nine hundred forty-two (94.2%) of 1000 individuals in Hovsgol(1995) and 775 (96.9%) of 1000 individuals in Omnogobi (1997) aged 40 years or older were examined. MAIN OUTCOME MEASURES: Anterior chamber depth was measured by optical pachymetry, slitlamp-mounted A-mode ultrasound, and handheld ultrasound. Gonioscopy was used to detect occludable angles, defined as one in which the trabecular meshwork was visible for less than 90 degrees of angle circumference. Primary open-angle glaucoma was diagnosed in subjects with an occludable angle and glaucomatous optic neuropathy with visual morbidity. The area under the curve in a receiver operating characteristic plot was used to compare test performance. RESULTS: Optical pachymetry outperformed the slitlamp-mounted ultrasound method of anterior chamber depth measurement (area under the curve, 0.93 and 0.90, respectively; z test, P = .001). Handheld ultrasound (area under the curve, 0.86) was inferior to optical measurement (z test, P = .001) but did not differ significantly from slitlamp ultrasound (z test, P = .06). The optical method gave sensitivity of 85% and specificity of 84% at a screening cutoff of less than 2.22 mm for detecting occludable angles. CONCLUSIONS: Measurement of axial anterior chamber depth can detect occludable angles in this Asian population and therefore may have a role in population screening for primary angle-closure glaucoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Robust Locally Weighted Regression and Smoothing Scatterplots
Cleveland, W. S. (1979) · Journal of the American Statistical Association · doi:10.1080/01621459.1979.10481038 · Cited by 11,594 · cited 1×
“The relationship between optical “true” ACD and age was summarized by means of the “lowess” procedure, which produces a robust smooth summary without imposing a regression model.(15) The area under the curve (AUC) of a receiver operating characteristic plot was used as an index of global efficacy of the screening test…”
MethodPrinciples and Practice of Screening for Disease.
(1968) · Annals of Internal Medicine · doi:10.7326/0003-4819-69-5-1085_2 · Cited by 3,066 · cited 1×
“If an effective test can be identified, PACG may meet the criteria for viable population screening.(8) Nd:YAG laser peripheral iridotomy probably represents a safe and effective prophylactic treatment.”
BackgroundNumber of people with glaucoma worldwide.
Quigley, H. A. (1996) · British Journal of Ophthalmology · doi:10.1136/bjo.80.5.389 · Cited by 2,998 · cited 2×
“Half of these are Asian, the majority ethnic Chinese.(7) A means of detecting those at risk (people with occludable drainage angles) is a prerequisite of a prevention program.”
BackgroundThe use of relative operating characteristic (ROC) curves in test performance evaluation.
Beck, & Shultz, E. K. (1986) · PubMed · Cited by 621
Lowe, R. F. (1970) · British Journal of Ophthalmology · doi:10.1136/bjo.54.3.161 · Cited by 521
Glaucoma in Mongolia: A Population-Based Survey in Hövsgöl Province, Northern Mongolia
Foster, P. J. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100140435011 · Cited by 474 · cited 2×
“Clustered simple random sampling was used in urban centers, and systematic sampling was used in rural areas.(12) The second phase of data collection was carried out in the Mongolian province of Ömnögobi between July 28 and October 2, 1997.”
MethodBiometry and Primary Angle-closure Glaucoma among Chinese, White, and Black Populations
Congdon, N. G., Youlin, Q., Quigley, H., Hung, P. T., Wang, T. H., Ho, T. C., & Tielsch, J. M. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30112-2 · Cited by 238
Primary angle-closure glaucoma. Oculometry, epidemiology, and genetics in a high risk population.
ALSBIRK, P. H. (1976) · PubMed · Cited by 202
The Prevalence of Glaucoma Among Eskimos of Northwest Alaska
Arkell, S. M., Lightman, D. A., Sommer, A. H., Taylor, H. R., Korshin, O. M., & Tielsch, J. M. (1987) · Archives of Ophthalmology · doi:10.1001/archopht.1987.01060040052031 · Cited by 182 · cited 7×
“Downloaded From: https://archopht.jamanetwork.com/ by a Non-Human Traffic (NHT) User on 03/09/2019 Although gonioscopy is the criterion standard for diagnosing an occludable angle, it is important to recognize that not all angles that look occludable will develop PACG.”
MethodResultInfluential
Cited by
Foster, P. J. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.8.1105 · Cited by 628
Glaucoma in China: how big is the problem?
Foster, P. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.11.1277 · Cited by 598
Xu, L., Cao, W. F., Wang, Y. X., Chen, C. X., & Jonas, J. B. (2008) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.01.004 · Cited by 241
Metadata
- Authors
- Devereux, J. G.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2000-02-01
- Volume
- 118
- Issue
- 2
- Pages
- 257
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2018434920
- Cited by
- 185
- References
- 13
- FWCI
- 5.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.