Corneal Thickness and Intraocular Pressure in the Barbados Eye Studies
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To describe the distribution of central corneal thickness (CCT) and evaluate its relationship to intraocular pressure (IOP) in the predominantly black population of the Barbados Eye Studies (BES). METHODS: Participants received a standardized examination, including pachymetry, applanation tonometry, and a comprehensive ophthalmologic evaluation. Analyses were based on data from all eyes, and generalized estimating equation methods were applied to account for the correlation between eyes. RESULTS: Among the 1142 consecutive participants with pachymetry measurements, the mean age was 64.3 years, and 58% were women. Black participants tended to have thinner corneas (mean thickness, 529.8 microm) than mixed (black and white) (537.8 microm) and white participants (545.2 microm), respectively. Among black participants, increasing values of CCT were significantly related to younger age (P<.001), diabetes history (P =.03), and refractive error (P =.03); a marginally significant relationship (with thinner corneas) was found with a clinical diagnosis of glaucoma (P =.07). Intraocular pressure was not associated with CCT in this population. CONCLUSIONS: Although other studies have reported a positive correlation between CCT and IOP, such a relationship was not substantiated in the black BES population. Black participants tended to have thinner corneas than white participants, whereas younger individuals, as well as those with a history of diabetes and more positive refractive errors, had thicker corneas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gordon, M. O. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.714 · Cited by 2,626 · cited 1×
“Most recently, results from the OHTS indicate that thinner CCT significantly predicted the development of OAG in multivariate analyses.(32)”
ResultHuman Corneal Thickness and Its Impact on Intraocular Pressure Measures
Doughty, M. J., & Zaman, M. L. (2000) · Survey of Ophthalmology · doi:10.1016/s0039-6257(00)00110-7 · Cited by 1,362 · cited 1×
“Asaresult,variouscorrectionmethodshave been proposed.(20,22,23) Although the majority of studies have reported that CCT and IOP are positively correlated,(9,16,17,20,21) this relationship was not corroborated in 2 recent reports by Feltgen et al(24) and Shah et al.”
BackgroundAPPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESS
EHLERS, N., BRAMSEN, T., & SPERLING, S. (1975) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1975.tb01135.x · Cited by 931 · cited 2×
“This assumptionwaslatershowntobeincorrect.(20,21) Asaresult,variouscorrectionmethodshave been proposed.”
BackgroundThe Barbados Eye Study: Prevalence of Open Angle Glaucoma
Leske, M. C. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090180121046 · Cited by 685 · cited 2×
“The baseline and follow-up examinations followed standardized protocols, as detailed elsewhere.(27,28) In summary, the examinations included anthropometric and blood pressure measurements; refraction and best-corrected visual acuities (Early Treatment Diabetic Retinopathy Study criteria); applanation tonometry; Humphr…”
BackgroundMethodCentral corneal thickness in the ocular hypertension treatment study (OHTS)
Brandt, J. D., Beiser, J. A., Kass, M. A., & Gordon, M. O. (2001) · Ophthalmology · doi:10.1016/s0161-6420(01)00760-6 · Cited by 626
Lens Opacities Classification System II (LOCS II)
Chylack, L. T. (1989) · Archives of Ophthalmology · doi:10.1001/archopht.1989.01070020053028 · Cited by 567
WOLFS, R. C. W., KLAVER, C. C. W., VINGERLING, J. R., GROBBEE, D. E., HOFMAN, A., & de JONG, P. T. V. M. (1997) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)71125-0 · Cited by 415 · cited 1×
“Other factors associated with CCT include age,(1,4,5) sex,(1) diagnosis of glaucoma,(3,6-11) diurnal changes,(12,13) refractive error,(1,5,14) genetic influences,(15) diabetes,(1) and intraocular pressure (IOP).(2,4,10,16-18) The relationship between CCT and IOP has been of interest since Goldmann and Schmidt(19) intr…”
BackgroundCorneal Thickness in Ocular Hypertension, Primary Open-angle Glaucoma, and Normal Tension Glaucoma
Copt, R.-P. (1999) · Archives of Ophthalmology · doi:10.1001/archopht.117.1.14 · Cited by 395
Shah, S., Chatterjee, A., Mathai, M., Kelly, S. P., Kwartz, J., Henson, D., & McLeod, D. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90498-0 · Cited by 320 · cited 4×
“Although the majority of studies have reported that CCT and IOP are positively correlated,(9,16,17,20,21) this relationship was not corroborated in 2 recent reports by Feltgen et al(24) and Shah et al.(25) The existence (or lack) of such correlation has clinical implications, since the lower IOP readings of persons wi…”
ResultInfluentialCentral corneal thickness and intraocular pressure in a Mongolian population,
Foster, P. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)96021-3 · Cited by 271 · cited 2×
“Some studies report no significant association,(10,17,30,31) whereas the BES and others found a definite inverse relationship.(1,4,5) Diabetes is highly prevalent in the BES, and individuals with a history of diabetes were found to have thicker corneas (P=.”
BackgroundDiurnal variations in human corneal thickness.
Harper, C., Boulton, M., BENNETT, D. B., Marcyniuk, B., Jarvis-Evans, J., Tullo, A. B., & Ridgway, A. E. A. (1996) · British Journal of Ophthalmology · doi:10.1136/bjo.80.12.1068 · Cited by 259
Incidence of open-angle glaucoma: the Barbados Eye Studies. The Barbados Eye Studies Group.
Leske, M. C., Connell, A. M., Wu, S., Nemesure, B. B., Li, X., SCHACHAT, A. P., & Hennis, A. J. M. (2001) · PubMed · Cited by 248
Self-citationFeltgen, N. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.1.85 · Cited by 238 · cited 1×
“Although a positive correlation between CCT and IOP has been demonstrated in some studies,(2,4,10,16-18) this result was not confirmed in 2 recent reports.(24,25) Results from our study indicate a positive correlation between IOP and CCT among the 25 white participants, but not among the large number of black particip…”
ResultRosa, F. A. L., Gross, R. L., & Orengo-Nania, S. D. (2001) · PubMed · Cited by 228
Distribution of Intraocular Pressure: The Barbados Eye Study
Leske, M. C. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100160221012 · Cited by 172 · cited 1×
“The purpose of this article is to present the distribution of CCT in a predominantly black population and to evaluate the relationship between corneal thickness and IOP in this population, which is known to have higher IOP measurements than white populations.(26)”
BackgroundStructural and Functional Studies of the Corneal Endothelium in Diabetes Mellitus
Keoleian, G. M., Pach, J. M., Hodge, D. O., Trocmé, S. D., & Bourne, W. M. (1992) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)75755-1 · Cited by 108
The effect of age on human corneal thickness
Siu, A. W., & HERSE, P. R. (1993) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1993.tb04959.x · Cited by 72 · cited 1×
“Numerous studies on corneal thickness have been conducted in white populations during the last few decades and have reported mean CCT measurements ranging from 520 μm to 579 μm.(1-3,5,7,9-11,17,30,31) Data relating to the distribution of corneal thickness in populations of African descent, however, are limited.”
Background
Cited by
Risk Factors for Incident Open-angle Glaucoma
Leske, M. C., Wu, S.-Y., Hennis, A., Honkanen, R., & Nemesure, B. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.03.017 · Cited by 774
Self-citationCentral Corneal Thickness and Corneal Hysteresis Associated With Glaucoma Damage
Congdon, N. G., Broman, A. T., Bandeen-Roche, K., Grover, D., & Quigley, H. A. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.12.007 · Cited by 507
Seddon, J. M. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.12.1728 · Cited by 384
Pepose, J. S., Feigenbaum, S. K., Qazi, M. A., Sanderson, J. P., & Roberts, C. J. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.09.036 · Cited by 369
Tonnu, P.-A. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.056622 · Cited by 357
Metadata
- Authors
- Nemesure, B.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2003-02-01
- Volume
- 121
- Issue
- 2
- Pages
- 240
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2148584466
- Cited by
- 228
- References
- 17
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.