CoChat
Cited by 172

The DOI matches its Crossref record.

Distribution of Intraocular Pressure: The Barbados Eye Study

Leske, M. Cristina · 1997 · Archives of Ophthalmology

Abstract

OBJECTIVE: To provide data on the distribution of intraocular pressure (IOP) in a predominantly black population, which has a high prevalence of open-angle glaucoma. DESIGN: Population-based prevalence study. SETTING AND PARTICIPANTS: Participants (N = 4601) (age range, 40-84 years) who had undergone applanation tonometry measurements in the Barbados Eye Study. Self-reported race was 93% black, 4% mixed (black and white), and 3% white or other. DATA COLLECTION: A standardized protocol included applanation tonometry and other ocular measurements, fundus photography, demographic data, and an interview. MAIN OUTCOME MEASURES: The average of 3 IOP measurements at the Barbados Eye Study visit was used to compare IOP by self-reported race. Descriptive data on IOP by age, sex, glaucoma status, and cup-disc ratio were examined in the black population. RESULTS: The IOP was highest in the population of African origin. The mean (+/-SD) IOP values for black, mixed, and white participants were 18.7 +/- 5.2, 18.2 +/- 3.8, and 16.5 +/- 3.0 mm Hg, respectively. An IOP greater than 21 mm Hg was present in 18.4%, 13.6%, and 4.6% of the black, mixed, and white participants, respectively. In analyses that were adjusted for age, sex, and glaucoma status, such values were 5 times as likely in black than white participants and 3.5 times as likely in mixed race participants (P < .01). Among the black participants, the mean IOP increased approximately 1 mm Hg for every increase in 10 years of age. After excluding persons with any type of glaucoma, suspected glaucoma, or a history of glaucoma treatment, women had significantly (P < .01) higher IOP values; however, no significant IOP trends by sex were evident in the group with glaucoma. The IOP was also positively associated (P < .05) with vertical cup-disc ratios. After 2 visits, the IOP remained 21 mm Hg or less in 21% of the persons with glaucoma vs 64% of those without glaucoma. CONCLUSIONS: In the black participants, the IOP was higher than in the white participants. The IOP was also associated with age and cup-disc ratios. The results showed that open-angle glaucoma and a high IOP alone have a different distribution by sex; although open-angle glaucoma was more frequent in men, ocular hypertension was more frequent in women. These data have implications for the detection and causation of open-angle glaucoma in this high-risk population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archopht.1997.01100160221012

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 172

Metadata

Authors
Leske, M. C.
Venue
Archives of Ophthalmology
Published
1997-08-01
Volume
115
Issue
8
Pages
1051
ISSN
0003-9950 (ISSN-L)
OpenAlex
W2144203674
Cited by
172
References
0
FWCI
3.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Distribution of Intraocular Pressure: The Barbados Eye Study. https://app.cochat.ai/papers/10.1001/archopht.1997.01100160221012
The paper
Leske, M. C. (1997). Distribution of Intraocular Pressure: The Barbados Eye Study. Archives of Ophthalmology. https://doi.org/10.1001/archopht.1997.01100160221012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.