The DOI matches its Crossref record.
Detection of Diabetic Foveal Edema: Contact Lens Biomicroscopy Compared With Optical Coherence Tomography
Abstract
OBJECTIVE: To compare contact lens biomicroscopy with optical coherence tomography (OCT) for the detection of diabetic foveal edema. METHODS: Study participants consisted of a convenient cohort of consecutive patients with diabetes mellitus seen at the Wilmer Eye Institute's Retinal Vascular Center, Baltimore, MD. Case characteristics were recorded and eyes were examined by 1 of 4 retina specialists by means of contact lens biomicroscopy. Edema involving the center of the macula was assessed as definitely present, questionably present, or definitely not present. The OCT testing was performed and interpreted by trained technicians, masked to the physicians' assessment of foveal edema. Agreement between OCT and contact lens examination for the absence or presence of foveal edema was evaluated. RESULTS: One hundred seventy-two eyes of 95 patients with diabetes were enrolled in August and September 2002. Foveal thickness was objectively measured by OCT in 170 (99%) of 172 cases. We found excellent agreement between OCT and contact lens examination for the absence or presence of foveal edema when OCT thickness was normal ( 300 microm). However, agreement was poor when foveal thickness was mildly increased on OCT (201-300 microm). CONCLUSIONS: Agreement between contact lens examination and OCT for the detection of diabetic foveal edema is poor when OCT thickening is mild. This suggests that contact lens biomicroscopy is relatively insensitive for the detection of mild foveal thickening apparent on OCT. Additional studies are needed to investigate the natural course of cases with mildly increased foveal thickness on OCT that do not appear thickened clinically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diabetic Macular Edema: Pathogenesis and Treatment
Bhagat, N., Grigorian, R. A., Tutela, A., & Zarbin, M. A. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.10.001 · Cited by 571
Normal Macular Thickness Measurements in Healthy Eyes Using Stratus Optical Coherence Tomography
Chan, A. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.2.193 · Cited by 424
Optical Coherence Tomographic Patterns of Diabetic Macular Edema
Kim, B. Y., Smith, S. D., & Kaiser, P. K. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.04.023 · Cited by 290
Kim, S. J., Equi, R., & Bressler, N. M. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.08.053 · Cited by 268
Robust and data-efficient generalization of self-supervised machine learning for diagnostic imaging
Azizi, S., Culp, L., Freyberg, J., Mustafa, B., Baur, S., Kornblith, S., Chen, T., Tomasev, N., Mitrović, J., Strachan, P., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01049-7 · Cited by 250
Metadata
- Authors
- Brown, J. C.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2004-03-01
- Volume
- 122
- Issue
- 3
- Pages
- 330
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2158769384
- Cited by
- 212
- References
- 0
- FWCI
- 15.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Diabetic Foveal Edema: Contact Lens Biomicroscopy Compared With Optical Coherence Tomography. https://app.cochat.ai/papers/10.1001/archopht.122.3.330
- The paper
- Brown, J. C. (2004). Detection of Diabetic Foveal Edema: Contact Lens Biomicroscopy Compared With Optical Coherence Tomography. Archives of Ophthalmology. https://doi.org/10.1001/archopht.122.3.330
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.