CoChat

Baseline Topographic Optic Disc Measurements Are Associated With the Development of Primary Open-Angle Glaucoma: The Confocal Scanning Laser Ophthalmoscopy Ancillary Study to the Ocular Hypertension Treatment Study

Zangwill, Linda M. · 2005 · Archives of Ophthalmology
Cited by 161

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To determine whether baseline confocal scanning laser ophthalmoscopy (CSLO) optic disc topographic measurements are associated with the development of primary open-angle glaucoma (POAG) in individuals with ocular hypertension. METHODS: Eight hundred sixty-five eyes from 438 participants in the CSLO Ancillary Study to the Ocular Hypertension Treatment Study with good-quality baseline CSLO images were included in this study. Each baseline CSLO parameter was assessed in univariate and multivariate proportional hazards models to determine its association with the development of POAG. RESULTS: Forty-one eyes from 36 CSLO Ancillary Study participants developed POAG. Several baseline topographic optic disc measurements were significantly associated with the development of POAG in both univariate and multivariate analyses, including larger cup-disc area ratio, mean cup depth, mean height contour, cup volume, reference plane height, and smaller rim area, rim area to disc area, and rim volume. In addition, classification as "outside normal limits" by the Heidelberg Retina Tomograph classification and the Moorfields Regression Analysis classifications (overall, global, temporal inferior, nasal inferior, and superior temporal regions) was significantly associated with the development of POAG. Within the follow-up period of this analysis, the positive predictive value of CSLO indexes ranged from 14% (Heidelberg Retina Tomograph classification and Moorfields Regression Analysis overall classification) to 40% for Moorfields Regression Analysis temporal superior classification. CONCLUSIONS: Several baseline topographic optic disc measurements alone or when combined with baseline clinical and demographic factors were significantly associated with the development of POAG among Ocular Hypertension Treatment Study participants. Longer follow-up is required to evaluate the true predictive accuracy of CSLO measures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archopht.123.9.1188

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 161

Metadata

Authors
Zangwill, L. M.
Venue
Archives of Ophthalmology
Published
2005-09-01
Volume
123
Issue
9
Pages
1188
ISSN
0003-9950 (ISSN-L)
OpenAlex
W2109627966
Cited by
161
References
19
FWCI
10.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Baseline Topographic Optic Disc Measurements Are Associated With the Development of Primary Open-Angle Glaucoma: The Confocal Scanning Laser Ophthalmoscopy Ancillary Study to the Ocular Hypertension Treatment Study. https://app.cochat.ai/papers/10.1001/archopht.123.9.1188
The paper
Zangwill, L. M. (2005). Baseline Topographic Optic Disc Measurements Are Associated With the Development of Primary Open-Angle Glaucoma: The Confocal Scanning Laser Ophthalmoscopy Ancillary Study to the Ocular Hypertension Treatment Study. Archives of Ophthalmology. https://doi.org/10.1001/archopht.123.9.1188

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.