Normal Macular Thickness Measurements in Healthy Eyes Using Stratus Optical Coherence Tomography
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To report normal macular thickness measurements in healthy eyes using the latest commercially available optical coherence tomography (OCT) mapping software, version 3.0, from the Stratus OCT (OCT3). METHODS: Thirty-seven eyes from 37 healthy subjects underwent a complete ophthalmologic examination, including OCT. Six radial scans, 6 mm in length and centered on the fovea, were obtained using the OCT3. Retinal thickness was automatically calculated by OCT mapping software. Measurements were displayed as the mean and standard deviation for each of the 9 regions defined in the Early Treatment Diabetic Retinopathy Study. RESULTS: Foveal thickness (mean thickness in the central 1000-microm diameter area) and central foveal thickness (mean thickness at the point of intersection of 6 radial scans) on the OCT3 were 212 +/- 20 and 182 +/- 23 microm, respectively. Macular thickness measurements were thinnest at the center of the fovea, thickest within 3-mm diameter of the center, and diminished toward the periphery of the macula. The temporal quadrant was thinner than the nasal quadrant. Central foveal thickness was also manually determined as 170 +/- 18 microm, approximately 12 microm less than the value automatically obtained from the OCT3 software. There was no correlation between age and foveal thickness (P = .80). CONCLUSIONS: Mean foveal thickness measurements were 38 to 62 microm thicker than previously reported values, while mean central foveal thickness measurements were 20 to 49 microm thicker than previously published values. This discrepancy should be considered when interpreting OCT scans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Optical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
Imaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
Patterns of diabetic macular edema with optical coherence tomography
Otani, T., Kishi, S., & Maruyama, Y. (1999) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00033-1 · Cited by 762
Quantitative Assessment of Macular Edema With Optical Coherence Tomography
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100080071031 · Cited by 710
Early Treatment Diabetic Retinopathy Study Design and Baseline Patient Characteristics
(1991) · Ophthalmology · doi:10.1016/s0161-6420(13)38009-9 · Cited by 683
Bouma, B. E., de Boer, J. F., Huang, D., Jang, I., Yonetsu, T., Leggett, C. L., Leitgeb, R. A., Sampson, D. D., Suter, M. J., Vakoc, B. J., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00162-2 · Cited by 649
Topography of diabetic macular edema with optical coherence tomography
Hee, M. R., Puliafito, C. A., Duker, J. S., Reichel, E., Coker, J. G., Wilkins, J. R., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)93601-6 · Cited by 633
Paunescu, L. A., Schuman, J. S., Price, L. L., Stark, P. C., Beaton, S., Ishikawa, H., Wollstein, G., & Fujimoto, J. G. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0514 · Cited by 536
Optical coherence tomography to detect and manage retinal disease and glaucoma
Jaffe, G. J., & Caprioli, J. (2004) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(03)00792-x · Cited by 505
Cited by
Ranibizumab for Macular Edema following Central Retinal Vein Occlusion
Brown, D. M., Campochiaro, P. A., Singh, R. P., Li, Z., Gray, S., Saroj, N., Rundle, A. C., Rubio, R. G., & Murahashi, W. Y. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.02.022 · Cited by 1,155
Ranibizumab for Macular Edema following Branch Retinal Vein Occlusion
Campochiaro, P. A., Heier, J. S., Feiner, L., Gray, S., Saroj, N., Rundle, A. C., Murahashi, W. Y., & Rubio, R. G. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.02.021 · Cited by 818
Maguire, M. G., Martin, D. F., Ying, G.-S., Jaffe, G. J., Daniel, E., Grunwald, J. E., Toth, C. A., Ferris, F. L., & Fine, S. L. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.03.045 · Cited by 708
IMI – Report on Experimental Models of Emmetropization and Myopia
Troilo, D., Smith, E. L., Nickla, D. L., Ashby, R., Tkatchenko, A. V., Ostrin, L. A., Gawne, T. J., Pardue, M. T., Summers, J. A., Kee, C.-S., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25967 · Cited by 487
Ranibizumab for Macular Edema Due to Retinal Vein Occlusions
Heier, J. S., Campochiaro, P. A., Yau, L., Li, Z., Saroj, N., Rubio, R. G., & Lai, P. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.12.005 · Cited by 470
Vascular Endothelial Growth Factor Is a Critical Stimulus for Diabetic Macular Edema
Nguyen, Q. D., Tatlipinar, S., Shah, S. M., Haller, J. A., Quinlan, E., Sung, J., Zimmer-Galler, I., Do, D. V., & Campochiaro, P. A. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.06.068 · Cited by 351
Nguyen, Q. D., Shah, S. M., Heier, J. S., Do, D. V., Lim, J., Boyer, D., Abraham, P., & Campochiaro, P. A. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.04.023 · Cited by 340
Campochiaro, P. A., Hafiz, G., Shah, S. M., Nguyen, Q. D., Ying, H., Do, D. V., Quinlan, E., Zimmer-Galler, I., Haller, J. A., Solomon, S. D., et al. (2008) · Molecular Therapy · doi:10.1038/mt.2008.10 · Cited by 321
Grover, S., Murthy, R. K., Brar, V. S., & Chalam, K. V. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2009.03.006 · Cited by 312
Jaffe, G. J., Martin, D. F., Toth, C. A., Daniel, E., Maguire, M. G., Ying, G.-S., Grunwald, J. E., & Huang, J. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.01.073 · Cited by 294
“Categories were based on the baseline quartiles except for retinal thickness, which was determined on the basis of the mean of healthy eyes on Stratus OCT measured manually 2 standard deviations.(9) General linear models were used to compare the retinal morphology responses or VA responses among 4 treatment groups, be…”
Song, W. K., Lee, S. C., Lee, E. S., Kim, C. Y., & Kim, S. S. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4189 · Cited by 264
Regional Variations in the Relationship between Macular Thickness Measurements and Myopia
Lam, D. S. C., Leung, K. S., Mohamed, S., Chan, W.-M., Palanivelu, M. S., Cheung, C. Y. L., Li, E. Y. M., Lai, R. Y. K., & Leung, C. K.-S. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0426 · Cited by 258
Sharma, S., Toth, C. A., Daniel, E., Grunwald, J. E., Maguire, M. G., Ying, G.-S., Huang, J., Martin, D. F., & Jaffe, G. J. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2015.12.002 · Cited by 231
“Categories reflected baseline quartiles except for retinal thickness, which was determined from the mean ( 2 standard deviations) retinal thickness measured manually on time-domain OCT scans from healthy eyes, as reported previously.(3,6) General linear models were used to compare the retinal morphology responses or V…”
MethodFingolimod-associated macular edema: Incidence, detection, and management
Jain, N., & Bhatti, M. T. (2012) · Neurology · doi:10.1212/wnl.0b013e318248deea · Cited by 202
Browning, D. J., Glassman, A. R., Aiello, L. P., Bressler, N. M., Bressler, S. B., Danis, R. P., Davis, M. D., Ferris, F. L., Huang, S. S., Kaiser, P. K., et al. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.12.004 · Cited by 164
Hagstrom, S. A., Ying, G.-S., Pauer, G. J. T., Sturgill-Short, G. M., Huang, J., Callanan, D. G., Kim, I. K., Klein, M. L., Maguire, M. G., & Martin, D. F. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.11.037 · Cited by 142
Rathinam, S. R., Babu, M., Thundikandy, R., Kanakath, A., Nardone, N., Esterberg, E., Lee, S. M., Enanoria, W. T. A., Porco, T. C., Browne, E. N., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.04.023 · Cited by 110
Rank, E. A., Sentosa, R., Harper, D. J., Salas, M., Gaugutz, A., Seyringer, D., Nevlacsil, S., Maese-Novo, A., Eggeling, M., Muellner, P., et al. (2021) · Light: Science & Applications · doi:10.1038/s41377-020-00450-0 · Cited by 106
Variable retinal phenotypes caused by mutations in the X-linked photopigment gene array
Mizrahi-Meissonnier, L., Merin, S., Banin, E., & Sharon, D. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4592 · Cited by 39
Metadata
- Authors
- Chan, A.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2006-02-01
- Volume
- 124
- Issue
- 2
- Pages
- 193
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2168451815
- Cited by
- 424
- References
- 14
- FWCI
- 24.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.