The DOI matches its Crossref record.
Normal Variability of Static Perimetric Threshold Values Across the Central Visual Field
Abstract
We assessed the variability of results in normal subjects of computerized static threshold perimetry of the central 30 degrees field. Variability of measured threshold values was highly dependent on eccentricity. This included variability among individuals, test-to-test variability within individuals, and intratest variability. All values were significantly larger in the midperiphery than centrally. We found that the mean sensitivity decrement with age was eccentricity dependent, so that the age-corrected normal visual field became not only depressed but also steeper with age. Distributions of individual pointwise deviations from the age-corrected normal mean thresholds were significantly nongaussian. The dependency of variability on test point location, the nongaussian distributions of deviations from age-corrected means, and the variability of age-induced sensitivity reduction should all be considered in the interpretation of computerized visual fields, and particularly in the design of statistical programs for field analysis. Programs not considering these factors are likely to result in misleading analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Retinal Ganglion Cell Atrophy Correlated With Automated Perimetry in Human Eyes With Glaucoma
Quigley, H. A., Dunkelberger, G. R., & Green, W. R. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90488-1 · Cited by 1,123
Age-related changes in the central visual field for short-wavelength-sensitive pathways
Johnson, C. A., Adams, A. J., Twelker, J. D., & Quigg, J. M. (1988) · Journal of the Optical Society of America A · doi:10.1364/josaa.5.002131 · Cited by 132
Predicting visual sensitivity in retinal prosthesis patients
Horsager, A., Greenwald, S. H., Weiland, J. D., Humayun, M. S., Greenberg, R. J., McMahon, M. J., Boynton, G. M., & Fine, I. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2595 · Cited by 107
Metadata
- Authors
- Heijl, A., Lindgren, G., & Olsson, J.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1987-11-01
- Volume
- 105
- Issue
- 11
- Pages
- 1544-1549
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2065289190
- Cited by
- 442
- References
- 0
- FWCI
- 11.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Normal Variability of Static Perimetric Threshold Values Across the Central Visual Field. https://app.cochat.ai/papers/10.1001/archopht.1987.01060110090039
- The paper
- Heijl, A., Lindgren, G., & Olsson, J. (1987). Normal Variability of Static Perimetric Threshold Values Across the Central Visual Field. Archives of Ophthalmology. https://doi.org/10.1001/archopht.1987.01060110090039
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.