The DOI matches its Crossref record.
Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography
Abstract
OBJECTIVE: To demonstrate a new diagnostic technique, optical coherence tomography, for high-resolution cross-sectional imaging of structures in the anterior segment of the human eye in vivo. Optical coherence tomography is a new, noninvasive, noncontact optical imaging modality that has spatial resolution superior to that of conventional clinical ultrasonography (< 20 microns) and high sensitivity (dynamic range, > 90 dB). DESIGN: Survey of intraocular structure and dimension measurements. SETTING: Laboratory. PATIENTS: Convenience sample. MAIN OUTCOME MEASURES: Correlation with range of accepted normal intraocular structure profiles and dimensions. RESULTS: Direct in vivo measurements with micrometer-scale resolution were performed of corneal thickness and surface profile (including visualization of the corneal epithelium), anterior chamber depth and angle, and iris thickness and surface profile. Dense nuclear cataracts were successfully imaged through their full thickness in a cold cataract model in calf eyes in vitro. CONCLUSIONS: Optical coherence tomography has potential as a diagnostic tool for applications in noncontact biometry, anterior chamber angle assessment, identification and monitoring of intraocular masses and tumors, and elucidation of abnormalities of the cornea, iris, and crystalline lens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantitative Assessment of Macular Edema With Optical Coherence Tomography
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100080071031 · Cited by 710
Applications and future directions for optical coherence tomography in dermatology*
Wan, B., Ganier, C., Du‐Harpur, X., Harun, N., Watt, F. M., Patalay, R., & Lynch, M. D. (2021) · British Journal of Dermatology · doi:10.1111/bjd.19553 · Cited by 148
Metadata
- Authors
- Izatt, J. A.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1994-12-01
- Volume
- 112
- Issue
- 12
- Pages
- 1584
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W1970756617
- Cited by
- 927
- References
- 0
- FWCI
- 11.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography. https://app.cochat.ai/papers/10.1001/archopht.1994.01090240090031
- The paper
- Izatt, J. A. (1994). Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography. Archives of Ophthalmology. https://doi.org/10.1001/archopht.1994.01090240090031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.