Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To demonstrate a new diagnostic technique, optical coherence tomography, for high-resolution cross-sectional imaging of structures in the anterior segment of the human eye in vivo. Optical coherence tomography is a new, noninvasive, noncontact optical imaging modality that has spatial resolution superior to that of conventional clinical ultrasonography (< 20 microns) and high sensitivity (dynamic range, > 90 dB). DESIGN: Survey of intraocular structure and dimension measurements. SETTING: Laboratory. PATIENTS: Convenience sample. MAIN OUTCOME MEASURES: Correlation with range of accepted normal intraocular structure profiles and dimensions. RESULTS: Direct in vivo measurements with micrometer-scale resolution were performed of corneal thickness and surface profile (including visualization of the corneal epithelium), anterior chamber depth and angle, and iris thickness and surface profile. Dense nuclear cataracts were successfully imaged through their full thickness in a cold cataract model in calf eyes in vitro. CONCLUSIONS: Optical coherence tomography has potential as a diagnostic tool for applications in noncontact biometry, anterior chamber angle assessment, identification and monitoring of intraocular masses and tumors, and elucidation of abnormalities of the cornea, iris, and crystalline lens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
In vivo retinal imaging by optical coherence tomography
Swanson, E. A., Izatt, J. A., Lin, C. P., Fujimoto, J. G., Schuman, J. S., Hee, M. R., Huang, D., & Puliafito, C. A. (1993) · Optics Letters · doi:10.1364/ol.18.001864 · Cited by 918
Self-citationOptical coherence-domain reflectometry: a new optical evaluation technique
Youngquist, R. C., Carr, S., & Davies, D. E. N. (1987) · Optics Letters · doi:10.1364/ol.12.000158 · Cited by 597
Takada, K., Yokohama, I., Chida, K., & Noda, J. (1987) · Applied Optics · doi:10.1364/ao.26.001603 · Cited by 371
Measurement of optical properties of biological tissues by low-coherence reflectometry
Schmitt, J. M., Knüttel, A., & Bonner, R. F. (1993) · Applied Optics · doi:10.1364/ao.32.006032 · Cited by 355
Micron‐resolution ranging of cornea anterior chamber by optical reflectometry
Huang, D., Wang, J., Lin, C. P., Puliafito, C. A., & Fujimoto, J. G. (1991) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900110506 · Cited by 153
Scanning Laser Tomography of the Living Human Eye
Bille, J. F., Dreher, A. W., & Zinser, G. (1990) · Springer eBooks · doi:10.1007/978-1-4613-8896-8_28 · Cited by 40
Cited by
Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Optical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
Schuman, J. S. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100050054031 · Cited by 879
Quantitative Assessment of Macular Edema With Optical Coherence Tomography
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100080071031 · Cited by 710
Reproducibility of Nerve Fiber Layer Thickness Measurements Using Optical Coherence Tomography
Schuman, J. S., Pedut-Kloizman, T., Hertzmark, E., Hee, M. R., Wilkins, J. R., Coker, J. G., Puliafito, C. A., Fujimoto, J. G., & Swanson, E. A. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30410-7 · Cited by 665
Topography of diabetic macular edema with optical coherence tomography
Hee, M. R., Puliafito, C. A., Duker, J. S., Reichel, E., Coker, J. G., Wilkins, J. R., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)93601-6 · Cited by 633
Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology
Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1206 · Cited by 566
Self-citationFercher, A. F. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231361 · Cited by 534
The Development, Commercialization, and Impact of Optical Coherence Tomography
Fujimoto, J., & Swanson, E. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19963 · Cited by 472
Optical coherence tomography of the human skin
Welzel, J., Lankenau, E., Birngruber, R., & Engelhardt, R. (1997) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(97)70072-0 · Cited by 442
Full-field optical coherence microscopy
Beaurepaire, E., Boccara, A. C., Lebec, M., Blanchot, L., & Saint-Jalmes, H. (1998) · Optics Letters · doi:10.1364/ol.23.000244 · Cited by 433
Optical Coherence Tomography of Age-related Macular Degeneration and Choroidal Neovascularization
Hee, M. R., Baumal, C. R., Puliafito, C. A., Duker, J. S., Reichel, E., Wilkins, J. R., Coker, J. G., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30512-5 · Cited by 416
Ultrahigh-resolution full-field optical coherence tomography
Dubois, A., Grieve, K., Moneron, G., Lecaque, R., Vabre, L., & Boccara, C. (2004) · Applied Optics · doi:10.1364/ao.43.002874 · Cited by 394
Characterization of Epiretinal Membranes Using Optical Coherence Tomography
Wilkins, J. R., Puliafito, C. A., Hee, M. R., Duker, J. S., Reichel, E., Coker, J. G., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30377-1 · Cited by 390
Brillouin Optical Microscopy for Corneal Biomechanics
Scarcelli, G., Pineda, R., & Yun, S. H. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8281 · Cited by 354
Optical coherence tomography and microscopy in gastrointestinal tissues
Izatt, J. A., Kulkarni, M. D., Wang, H.-W., Kobayashi, K., & Sivak, M. V. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577331 · Cited by 350
Self-citationOptical Coherence Tomography: History, Current Status, and Laboratory Work
Gabriele, M. L., Wollstein, G., Ishikawa, H., Kagemann, L., Xu, J., Folio, L. S., & Schuman, J. S. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6312 · Cited by 310
Bowd, C. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.1.22 · Cited by 308
Grulkowski, I., Liu, J. J., Potsaid, B., Jayaraman, V., Lu, C. D., Jiang, J., Cable, A. E., Duker, J. S., & Fujimoto, J. G. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002733 · Cited by 308
Optical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259
Ko, T. H., Fujimoto, J. G., Schuman, J. S., Paunescu, L. A., Kowalevicz, A. M., Hartl, I., Drexler, W., Wollstein, G., Ishikawa, H., & Duker, J. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.05.027 · Cited by 224
Gora, M., Karnowski, K., Szkulmowski, M., Kaluzny, B. J., Huber, R., Kowalczyk, A., & Wojtkowski, M. (2009) · Optics Express · doi:10.1364/oe.17.014880 · Cited by 217
Corneal Pachymetry Mapping with High-speed Optical Coherence Tomography
Li, Y., Shekhar, R., & Huang, D. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.01.048 · Cited by 217
The diagnosis of limbal stem cell deficiency
Le, Q., Xu, J., & Deng, S. X. (2018) · The Ocular Surface · doi:10.1016/j.jtos.2017.11.002 · Cited by 216
“OCT, a noninvasive and noncontact imaging technique that was first introduced in 1994 [111], is based on lowcoherence interferometry.”
BackgroundLiang, W., Mavadia, J., & Li, X. (2013) · Series in Medical Physics and Biomedical Engineering · doi:10.1201/b16289-14 · Cited by 215
Thomas, B. J., Galor, A., Nanji, A. A., El Sayyad, F., Wang, J., Dubovy, S. R., Joag, M. G., & Karp, C. L. (2014) · The Ocular Surface · doi:10.1016/j.jtos.2013.11.001 · Cited by 184
“The posterior segment was the first ocular structure to be imaged, followed by the first reported use of anterior segment OCT in 1994 by Izatt, et al.(1) A number of commercially available TD-OCT machines were subsequently designed for imaging of the anterior segment, and posterior segment OCT machines,”
MethodInfluentialApplications and future directions for optical coherence tomography in dermatology*
Wan, B., Ganier, C., Du‐Harpur, X., Harun, N., Watt, F. M., Patalay, R., & Lynch, M. D. (2021) · British Journal of Dermatology · doi:10.1111/bjd.19553 · Cited by 148
Metadata
- Authors
- Izatt, J. A.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1994-12-01
- Volume
- 112
- Issue
- 12
- Pages
- 1584
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W1970756617
- Cited by
- 927
- References
- 7
- FWCI
- 11.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.