Effect of Pulse Duration on Size and Character of the Lesion in Retinal Photocoagulation
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To systematically evaluate the effects of laser beam size, power, and pulse duration of 1 to 100 milliseconds on the characteristics of ophthalmoscopically visible retinal coagulation lesions. METHODS: A 532-nm Nd:YAG laser was used to irradiate 36 retinas in Dutch Belt rabbits with retinal beam sizes of 66, 132, and 330 mum. Lesions were clinically graded 1 minute after placement, their size measured by digital imaging, and their depth assessed histologically at different time points. RESULTS: Retinal lesion size increased linearly with laser power and logarithmically with pulse duration. The width of the therapeutic window, defined by the ratio of the threshold power for producing a rupture to that of a mild coagulation, decreased with decreasing pulse durations. For 132- and 330-mum retinal beam sizes, the therapeutic window declined from 3.9 to 3.0 and 5.4 to 3.7, respectively, as pulse duration decreased from 100 to 20 ms. At pulse durations of 1 millisecond, the therapeutic window decreased to unity, at which point rupture and a mild lesion were equally likely to occur. CONCLUSIONS: At shorter pulse durations, the width and axial extent of the retinal lesions are smaller and less dependent on variations in laser power than at longer durations. The width of the therapeutic window, a measure of relative safety, increases with the beam size. CLINICAL RELEVANCE: Pulse durations of approximately 20 milliseconds represent an optimal compromise between the favorable impact of speed, higher spatial localization, and reduced collateral damage on one hand, and sufficient width of the therapeutic window (> 3) on the other.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heating of the eye by a retinal prosthesis: modeling, cadaver and in vivo study
Opie, N. L., Burkitt, A. N., Meffin, H., & Grayden, D. B. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2171961 · Cited by 59
“6 mW [6]–[8]; however, retinal whitening, edema, and fundus lesions have been induced by 50 mW of power dissipated directly into the retinal tissue [7], [9].”
BackgroundRetinal safety of near infrared radiation in photovoltaic restoration of sight.
Lorach, H., Wang, J., Lee, D. Y., Dalal, R., Huie, P., & Palanker, D. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000013 · Cited by 33
Self-citation
Metadata
- Authors
- Jain, A.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2008-01-01
- Volume
- 126
- Issue
- 1
- Pages
- 78
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2136919879
- Cited by
- 179
- References
- 0
- FWCI
- 16.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Pulse Duration on Size and Character of the Lesion in Retinal Photocoagulation. https://app.cochat.ai/papers/10.1001/archophthalmol.2007.29
- The paper
- Jain, A. (2008). Effect of Pulse Duration on Size and Character of the Lesion in Retinal Photocoagulation. Archives of Ophthalmology. https://doi.org/10.1001/archophthalmol.2007.29
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.