Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 291

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Whole-Body PET Imaging With [18F]Fluorodeoxyglucose in Management of Recurrent Colorectal Cancer

Valk, P. E.·1999·Archives of Surgery

Abstract

HYPOTHESIS: Metabolic imaging by positron emission tomography (PET) using [18F]fluorodeoxyglucose will be more accurate than anatomic imaging by computed tomography (CT) for detection of recurrent colorectal cancer. More accurate staging of recurrent tumor by PET will lead to more appropriate management decisions. DESIGN: Prospective blinded study comparing PET with CT, using histologic diagnosis, serial CT imaging, and clinical follow-up as criterion standards, with a fully blinded, retrospective reinterpretation of PET studies. Changes in diagnosis resulting from PET findings were correlated with subsequent treatment and surgical findings. Potential cost savings resulting from use of PET for preoperative staging were calculated. SETTING: Private practice in an outpatient tertiary referral center. PATIENTS: A group of 155 consecutive patients with imaging for diagnosis or staging of recurrent colorectal cancer. Twenty-one patient (14%) were excluded due to lack of a criterion standard. Computed tomographic scans were available for comparison for 115 patients. RESULTS: Positron emission tomographic scan sensitivity and specificity were 93% and 98%, respectively, compared with 69% and 96% for CT. Ninety-five percent confidence intervals for the differences between the modalities were 16% to 32% for sensitivity and 1% to 5% for specificity. The sensitivity of both modalities varied with anatomic site of recurrence. Positron emission tomographic scans were true positive in 12 (67%) of 18 patients with elevated serum carcinoembryonic antigen levels and negative CT findings. In 23 (29%) of 78 preoperative studies in which CT showed a single site of recurrence, PET showed tumor at additional sites. At surgery, nonresectable, PET-negative tumor was found in 7 (17%) of 42 patients who had PET evidence of localized recurrence only. Potential savings resulting from demonstration of nonresectable tumor by PET were calculated at $3003 per preoperative study. CONCLUSIONS: Positron emission tomography was more sensitive and specific than CT for detection of recurrent colorectal cancer. Preoperative detection of nonresectable tumor by PET may avoid unnecessary surgery, and thereby reduce the cost of patient treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archsurg.134.5.503

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Metadata

Authors
Valk, P. E.
Venue
Archives of Surgery
Published
1999-05-01
Volume
134
Issue
5
Pages
503-511
ISSN
0004-0010 (ISSN-L)
OpenAlex
W2093096127
Cited by
291
References
21
FWCI
23.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Whole-Body PET Imaging With [18F]Fluorodeoxyglucose in Management of Recurrent Colorectal Cancer. https://app.cochat.ai/papers/10.1001/archsurg.134.5.503
The paper
Valk, P. E. (1999). Whole-Body PET Imaging With [18F]Fluorodeoxyglucose in Management of Recurrent Colorectal Cancer. Archives of Surgery. https://doi.org/10.1001/archsurg.134.5.503

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.